메뉴 건너뛰기




Volumn 65, Issue 1, 2011, Pages 17-21

Safety in the preparation of cytotoxic drugs: How to integrate gravimetric control in the quality assurance policy?

Author keywords

Antineoplastic agent; Balance; Chemotherapy; Compounding unit; Isolator; Weight control

Indexed keywords

CARBOPLATIN; CETUXIMAB; CISPLATIN; CYCLOPHOSPHAMIDE; CYTOTOXIC AGENT; DOCETAXEL; DOXORUBICIN; EPIRUBICIN; ETOPOSIDE; FLUOROURACIL; GEMCITABINE; IRINOTECAN; NAVELBINE; OXALIPLATIN; TRASTUZUMAB;

EID: 79951674296     PISSN: 07533322     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.biopha.2010.12.014     Document Type: Article
Times cited : (11)

References (16)
  • 1
    • 33644965081 scopus 로고    scopus 로고
    • Preparation of antineoplastic agents
    • Descoutures J.M. Preparation of antineoplastic agents. Ann Pharm Fr 2006, 64(1):7-16.
    • (2006) Ann Pharm Fr , vol.64 , Issue.1 , pp. 7-16
    • Descoutures, J.M.1
  • 2
    • 76049113981 scopus 로고    scopus 로고
    • Global initiative of quality assurance within the framework of the security of the cytotoxic circuit
    • Hippy-Muller C., Danicourt-Barrier F., Hochart S., et al. Global initiative of quality assurance within the framework of the security of the cytotoxic circuit. J Pharm Clin 2009, 28(4):199-206.
    • (2009) J Pharm Clin , vol.28 , Issue.4 , pp. 199-206
    • Hippy-Muller, C.1    Danicourt-Barrier, F.2    Hochart, S.3
  • 3
    • 79951672237 scopus 로고    scopus 로고
    • Ministère de la Santé et des Solidarités. Journal officiel de la république française du 26 août 2005. Décret no 2005-1023 du 24 août 2005 relatif au contrat de bon usage des médicaments et des produits et prestations mentionnés à l'article L162-22-7 du Code de la Sécurité sociale
    • Ministère de la Santé et des Solidarités. Journal officiel de la république française du 26 août 2005. Décret no 2005-1023 du 24 août 2005 relatif au contrat de bon usage des médicaments et des produits et prestations mentionnés à l'article L162-22-7 du Code de la Sécurité sociale.
  • 4
    • 0031839404 scopus 로고    scopus 로고
    • Cytotoxics centralized preparation unit: quality assessment
    • Pelus E., Dellanegra M., Chaterly D., et al. Cytotoxics centralized preparation unit: quality assessment. J Pharm Clin 1998, 17:97-102.
    • (1998) J Pharm Clin , vol.17 , pp. 97-102
    • Pelus, E.1    Dellanegra, M.2    Chaterly, D.3
  • 5
    • 12844284475 scopus 로고    scopus 로고
    • Prevention of preparation errors of cytotoxic drugs in centralized units: from epidemiology to quality assurance
    • Martin F., Legat C., Coutet J., et al. Prevention of preparation errors of cytotoxic drugs in centralized units: from epidemiology to quality assurance. Bull Cancer 2004, 91(12):972-976.
    • (2004) Bull Cancer , vol.91 , Issue.12 , pp. 972-976
    • Martin, F.1    Legat, C.2    Coutet, J.3
  • 6
    • 0029819279 scopus 로고    scopus 로고
    • Electronic balance as quality assurance for cytotoxic drug admixtures
    • Ritter H., Trissel L., Anderson R., et al. Electronic balance as quality assurance for cytotoxic drug admixtures. Am J Health Syst Pharm 1996, 53(19):2318-2320.
    • (1996) Am J Health Syst Pharm , vol.53 , Issue.19 , pp. 2318-2320
    • Ritter, H.1    Trissel, L.2    Anderson, R.3
  • 7
    • 42649093143 scopus 로고    scopus 로고
    • Choice and set-up of weight control for the final step of release in the centralized unit of a hospital preparing cytotoxic drugs
    • Le Garlantezec P., Aupee O., Bohand X., et al. Choice and set-up of weight control for the final step of release in the centralized unit of a hospital preparing cytotoxic drugs. Pharm Hosp 2008, 43(172):19-27.
    • (2008) Pharm Hosp , vol.43 , Issue.172 , pp. 19-27
    • Le Garlantezec, P.1    Aupee, O.2    Bohand, X.3
  • 8
    • 79951675407 scopus 로고    scopus 로고
    • Création d'un outil informatique d'exploitation des pesées de préparations de cytostatiques
    • Caquelin J.B., Heluin Y., Plivard C., et al. Création d'un outil informatique d'exploitation des pesées de préparations de cytostatiques. Congrès Hopipharm Marseille 2009 2009.
    • (2009) Congrès Hopipharm Marseille 2009
    • Caquelin, J.B.1    Heluin, Y.2    Plivard, C.3
  • 9
    • 0029892441 scopus 로고    scopus 로고
    • Accuracy and reproductibility of seryngue measurements
    • Lee S.N., Wong A.H., Mayer A., et al. Accuracy and reproductibility of seryngue measurements. Am J Health Syst Pharm 1996, 53:1166-1169.
    • (1996) Am J Health Syst Pharm , vol.53 , pp. 1166-1169
    • Lee, S.N.1    Wong, A.H.2    Mayer, A.3
  • 10
    • 79951680418 scopus 로고    scopus 로고
    • Mise en place d'un contrôle pondéral des préparations de 5-fluorouracile en diffuseurs portables
    • Le Franc B., Granry S., Griesemann E. Mise en place d'un contrôle pondéral des préparations de 5-fluorouracile en diffuseurs portables. Congrès Hopipharm Strasbourg 2007 2007.
    • (2007) Congrès Hopipharm Strasbourg 2007
    • Le Franc, B.1    Granry, S.2    Griesemann, E.3
  • 11
    • 0034040385 scopus 로고    scopus 로고
    • Comparison of two fast physical measurements for the dose control of cytotoxic injectable preparations before administration. Application to 5-fluorouracile
    • Basuyau F., Brunelle P. Comparison of two fast physical measurements for the dose control of cytotoxic injectable preparations before administration. Application to 5-fluorouracile. J Pharm Clin 2000, 19(1):5-9.
    • (2000) J Pharm Clin , vol.19 , Issue.1 , pp. 5-9
    • Basuyau, F.1    Brunelle, P.2
  • 13
    • 0036663306 scopus 로고    scopus 로고
    • New program for quality control of cytotoxics manufactured in centralized unit
    • Watt S., Antier D., Jacques V., et al. New program for quality control of cytotoxics manufactured in centralized unit. J Pharm Clin 2002, 21(3):179-182.
    • (2002) J Pharm Clin , vol.21 , Issue.3 , pp. 179-182
    • Watt, S.1    Antier, D.2    Jacques, V.3
  • 14
    • 0034954022 scopus 로고    scopus 로고
    • Incidence and risk factors of preparation errors in a centralized cytotoxic preparation unit
    • Limat S., Drouhin J.P., Demesmay K., et al. Incidence and risk factors of preparation errors in a centralized cytotoxic preparation unit. Pharm World Sci 2001, 23(3):102-106.
    • (2001) Pharm World Sci , vol.23 , Issue.3 , pp. 102-106
    • Limat, S.1    Drouhin, J.P.2    Demesmay, K.3
  • 15
    • 79951673560 scopus 로고    scopus 로고
    • Ministère de la Santé, de la Jeunesse et des Sports. Décision du 5 novembre 2007. Journal officiel de la république française du 21 novembre 2007. Bonnes pratiques de préparation en établissements de santé, en établissements médicosociaux et en officines de pharmacie
    • Ministère de la Santé, de la Jeunesse et des Sports. Décision du 5 novembre 2007. Journal officiel de la république française du 21 novembre 2007. Bonnes pratiques de préparation en établissements de santé, en établissements médicosociaux et en officines de pharmacie.
  • 16
    • 69949130283 scopus 로고    scopus 로고
    • Feasibility study of extemporaneous control of cytotoxic preparations: tests with an innovating spectrometer coupling UV/visible and IR detections
    • Ripoche N., Baumgartner P., Audeval C., et al. Feasibility study of extemporaneous control of cytotoxic preparations: tests with an innovating spectrometer coupling UV/visible and IR detections. EJHP Pract 2009, 15(1):28-31.
    • (2009) EJHP Pract , vol.15 , Issue.1 , pp. 28-31
    • Ripoche, N.1    Baumgartner, P.2    Audeval, C.3