메뉴 건너뛰기




Volumn 209, Issue 1, 2011, Pages 39-46

T2 distribution mapping profiles with phase-encode MRI

Author keywords

Porous solids; Spin echo SPI; SPRITE; T2 mapping

Indexed keywords

CEMENT PASTE; FLOW PROCESS; LOCAL GRADIENTS; MEASUREMENT TIME; PARAMAGNETIC IMPURITY; POROUS SOLIDS; SITE-SPECIFIC; SPATIAL ENCODING; SPIN ECHO; SPRITE; T2 MAPPING;

EID: 79951673961     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2010.12.006     Document Type: Article
Times cited : (58)

References (27)
  • 3
    • 0030208180 scopus 로고    scopus 로고
    • Magnetic resonance imaging for the determination of magnetic susceptibility of materials
    • O. Beuf, A. Briguet, M. Lissac, and R. Davis Magnetic resonance imaging for the determination of magnetic susceptibility of materials J. Magn. Reson. Ser. B 112 1996 111 118 (Pubitemid 126758713)
    • (1996) Journal of Magnetic Resonance - Series B , vol.112 , Issue.2 , pp. 111-118
    • Beuf, O.1    Briguet, A.2    Lissac, M.3    Davis, R.4
  • 4
    • 0029809615 scopus 로고    scopus 로고
    • A robust method for calculating geometric mean times from multiexponential relaxation data, using only a few data points and only a few elementary operations
    • DOI 10.1016/S0730-725X(96)00175-0, PII S0730725X96001755
    • G.C. Borgia, V. Bortolotti, R.J.S. Brown, and P. Fantazzini A robust method for calculating geometric mean times from multiexponential relaxation data, using only a few data points and only a few elementary operations Magn. Reson. Imaging 14 1996 895 897 (Pubitemid 26415987)
    • (1996) Magnetic Resonance Imaging , vol.14 , Issue.7-8 , pp. 895-897
    • Borgia, G.C.1    Bortolotti, V.2    Brown, R.J.S.3    Fantazzini, P.4
  • 5
    • 0001040879 scopus 로고    scopus 로고
    • Different "average" nuclear magnetic resonance relaxation times for correlation with fluid-flow permeability and irreducible water saturation in water-saturated sandstones
    • G.C. Borgia, R.J.S. Brown, and P. Fantazzini Different "average" nuclear magnetic resonance relaxation times for correlation with fluid-flow permeability and irreducible water saturation in water-saturated sandstones J. Appl. Phys. 82 1997 4197 4204 (Pubitemid 127584800)
    • (1997) Journal of Applied Physics , vol.82 , Issue.9 , pp. 4197-4204
    • Borgia, G.C.1    Brown, R.J.S.2    Fantazzini, P.3
  • 6
    • 0032100922 scopus 로고    scopus 로고
    • A method for approximating fractional power average relaxation times without inversion of multiexponential relaxation data
    • DOI 10.1016/S0730-725X(98)00039-3, PII S0730725X98000393
    • G.C. Borgia, V. Bortolotti, R.J.S. Brown, and P. Fantazzini A method for approximating fractional power average relaxation times without inversion of multiexponential relaxation data Magn. Reson. Imaging 16 1998 625 627 (Pubitemid 28506335)
    • (1998) Magnetic Resonance Imaging , vol.16 , Issue.5-6 , pp. 625-627
    • Borgia, G.C.1    Bortolotti, V.2    Brown, R.J.S.3    Fantazzini, P.4
  • 8
    • 33746312416 scopus 로고    scopus 로고
    • Centric-scan SPRITE magnetic resonance imaging with prepared magnetisation
    • DOI 10.1016/j.jmr.2006.05.012, PII S1090780706001431
    • A.A. Khrapitchev, B. Newling, and B.J. Balcom Centric-scan SPRITE magnetic resonance imaging with prepared magnetisation J. Magn. Reson. 181 2006 271 279 (Pubitemid 44107744)
    • (2006) Journal of Magnetic Resonance , vol.181 , Issue.2 , pp. 271-279
    • Khrapitchev, A.A.1    Newling, B.2    Balcom, B.J.3
  • 9
    • 0002312260 scopus 로고
    • Sensitivity and resolution of constant-time imaging
    • S. Gravina, and D.G. Cory Sensitivity and resolution of constant-time imaging J. Magn. Reson. Ser. B 104 1994 53 61
    • (1994) J. Magn. Reson. Ser. B , vol.104 , pp. 53-61
    • Gravina, S.1    Cory, D.G.2
  • 11
    • 0009600288 scopus 로고
    • The effect of amplitude imbalance on compensated Carr-Purcell sequences
    • T. Gullion The effect of amplitude imbalance on compensated Carr-Purcell sequences J. Magn. Reson. Ser. A 101 1993 320 323
    • (1993) J. Magn. Reson. Ser. A , vol.101 , pp. 320-323
    • Gullion, T.1
  • 12
    • 67349158685 scopus 로고    scopus 로고
    • Spin echo SPI methods for quantitative analysis of fluids in porous media
    • L. Li, H. Han, and B.J. Balcom Spin echo SPI methods for quantitative analysis of fluids in porous media J. Magn. Reson. 198 2009 252 260
    • (2009) J. Magn. Reson. , vol.198 , pp. 252-260
    • Li, L.1    Han, H.2    Balcom, B.J.3
  • 13
    • 34247383142 scopus 로고    scopus 로고
    • 2 MRI by means of a Pulsed Field Gradient-Multi Spin Echo method
    • DOI 10.1016/j.jmr.2006.12.015, PII S109078070700002X
    • 2 MRI by means of a pulsed field gradient-multi spin echo method J. Magn. Reson. 185 2007 230 239 (Pubitemid 46635230)
    • (2007) Journal of Magnetic Resonance , vol.185 , Issue.2 , pp. 230-239
    • Windt, C.W.1    Vergeldt, F.J.2    Van As, H.3
  • 16
    • 0034794435 scopus 로고    scopus 로고
    • Unifying linear prior-information-driven methods for accelerated image acquisition
    • DOI 10.1002/mrm.1242
    • J. Tsao, B. Behnia, and A.G. Webb Unifying linear prior-information- driven methods for accelerated image acquisition Magn. Reson. Med. 46 2001 652 660 (Pubitemid 32906133)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.4 , pp. 652-660
    • Tsao, J.1    Behnia, B.2    Webb, A.G.3
  • 18
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • DOI 10.1002/mrm.21391
    • M. Lustig, D. Donoho, and J.M. Pauly Sparse MRI: the application of compressed sensing for rapid MR imaging Magn. Reson. Med. 58 2007 1182 1195 (Pubitemid 350234205)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 19
    • 0032943531 scopus 로고    scopus 로고
    • 2 relaxation times in lung using a clinical MRI scanner
    • DOI 10.1002/(SICI)1522-2586(199905)9:5<699::AID-JMRI12>3.0.CO;2-H
    • M. Estilaei, A. MacKay, K. Whittall, and J. Mayo In vitro measurements of water content and T-2 relaxation times in lung using a clinical MRI scanner J. Magn. Reson. Imaging 9 1999 699 703 (Pubitemid 29211164)
    • (1999) Journal of Magnetic Resonance Imaging , vol.9 , Issue.5 , pp. 699-703
    • Estilaei, M.1    MacKay, A.2    Whittall, K.3    Mayo, J.4
  • 21
    • 21244469507 scopus 로고    scopus 로고
    • The internal magnetic field distribution, and single exponential magnetic resonance free induction decay, in rocks
    • DOI 10.1016/j.jmr.2005.05.001, PII S1090780705001485
    • Q. Chen, A.E. Marble, B.G. Colpitts, and B.J. Balcom The internal magnetic field distribution, and single exponential magnetic resonance free induction decay, in rocks J. Magn. Reson. 175 2005 300 308 (Pubitemid 40891686)
    • (2005) Journal of Magnetic Resonance , vol.175 , Issue.2 , pp. 300-308
    • Chen, Q.1    Marble, A.E.2    Colpitts, B.G.3    Balcom, B.J.4
  • 22
    • 0033061563 scopus 로고    scopus 로고
    • 2 relaxation for in vivo human brain?
    • DOI 10.1002/(SICI)1522-2594(199906)41:6<1255::AID-MRM23>3.0.CO;2-I
    • K.P. Whittall, A.L. MacKay, and D.K.B. Li Are mono-exponential fits to a few echoes sufficient to determine T-2 relaxation for in vivo human brain? Magn. Reson. Med. 41 1999 1255 1257 (Pubitemid 29247295)
    • (1999) Magnetic Resonance in Medicine , vol.41 , Issue.6 , pp. 1255-1257
    • Whittall, K.P.1    MacKay, A.L.2    Li, D.K.B.3
  • 24
    • 48149108723 scopus 로고    scopus 로고
    • Fat and moisture content determination with unilateral NMR
    • O.V. Petrov, J. Hay, I.V. Mastikhin, and B.J. Balcom Fat and moisture content determination with unilateral NMR Food Res. Int. 41 2008 758 764
    • (2008) Food Res. Int. , vol.41 , pp. 758-764
    • Petrov, O.V.1    Hay, J.2    Mastikhin, I.V.3    Balcom, B.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.