메뉴 건너뛰기




Volumn 70, Issue 2, 2011, Pages 358-365

Effect on dynamic mechanical stability and interfragmentary movement of angle-stable locking of intramedullary nails in unstable distal tibia fractures: A biomechanical study

Author keywords

Angle stable locking; Biomechanical study; Distal tibia fracture; Intramedullary nail; Unstable fracture

Indexed keywords

ADULT; AGED; ANGLE STABLE LOCKING SCREW; ARTICLE; BONE BOWING; BONE DENSITY; BONE NAIL; BONE SCREW; DISTAL TIBIA FRACTURE; FEMALE; HUMAN; HUMAN TISSUE; INTRAMEDULLARY NAIL; MALE; OSTEOTOMY; PRIORITY JOURNAL;

EID: 79951672810     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/TA.0b013e3181dbaaaf     Document Type: Article
Times cited : (44)

References (19)
  • 2
    • 30344451992 scopus 로고    scopus 로고
    • Distal metaphyseal fractures of tibia: A prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation
    • discussion 1223
    • Im GI, Tae SK. Distal metaphyseal fractures of tibia: A prospective randomized trial of closed reduction and intramedullary nail versus open reduction an plate and screws fixation. J Trauma. 2005;59: 1219-1223; discussion 1223.
    • (2005) J Trauma. , vol.59 , pp. 1219-1223
    • Im, G.I.1    Tae, S.K.2
  • 3
    • 0033881832 scopus 로고    scopus 로고
    • Interlocking intramedullary nailing in distal tibial fractures
    • Tyllianakis M, Megas P, Giannikas D, Lambiris E. Interlocking intramedullary nailing in distal tibial fractures. Orthopedics. 2000;23:805-808. (Pubitemid 30641676)
    • (2000) Orthopedics , vol.23 , Issue.8 , pp. 805-808
    • Tyllianakis, M.1    Megas, P.2    Giannikas, D.3    Lambiris, E.4
  • 4
    • 35348834164 scopus 로고    scopus 로고
    • Treatment of distal tibial fractures: Plate versus nail: A retrospective outcome analysis of matched pairs of patients
    • DOI 10.1007/s00264-006-0237-1
    • Janssen KW, Biert J, van Kampen A. Treatment of distal tibial fractures: Plate versus nail: A retrospective outcome analysis of matched pairs of patients. Int Orthop. 2007;31:709-714. (Pubitemid 47573359)
    • (2007) International Orthopaedics , vol.31 , Issue.5 , pp. 709-714
    • Janssen, K.W.1    Biert, J.2    Van Kampen, A.3
  • 5
    • 43049088134 scopus 로고    scopus 로고
    • Radiographic and clinical comparisons of distal tibia shaft fractures (4 to 11 cm proximal to the plafond): Plating versus intramedullary nailing
    • DOI 10.1097/BOT.0b013e31816ed974, PII 0000513120080500000004
    • Vallier HA, Le TT, Bedi A. Radiographic and clinical comparisons of distal tibia shaft fractures (4 to 11 cm proximal to the plafond): Plating versus intramedullary nailing. J Orthop Trauma. 2008;22:307-311. (Pubitemid 351630243)
    • (2008) Journal of Orthopaedic Trauma , vol.22 , Issue.5 , pp. 307-311
    • Vallier, H.A.1    Le, T.T.2    Bedi, A.3
  • 8
    • 67649653924 scopus 로고    scopus 로고
    • Micromotion at the fracture site after tibial nailing with four unreamed small-diameter nails-a biomechanical study using a distal tibia fracture model
    • Schüller M, Weninger P, Tschegg E, Jamek M, Redl H, Stanzl-Tschegg S. Micromotion at the fracture site after tibial nailing with four unreamed small-diameter nails-a biomechanical study using a distal tibia fracture model. J Trauma. 2009;66:1391-1397.
    • (2009) J Trauma. , vol.66 , pp. 1391-1397
    • Schüller, M.1    Weninger, P.2    Tschegg, E.3    Jamek, M.4    Redl, H.5    Stanzl-Tschegg, S.6
  • 10
    • 0027342530 scopus 로고
    • Influences of some design parameters on the biomechanics of the unreamed tibial intramedullary nail
    • Henley MB, Meier M, Tencer AF. Influences of some design parameters on the biomechanics of the unreamed tibial intramedullary nail. J Orthop Trauma. 1993;7:311-319.
    • (1993) J Orthop Trauma. , vol.7 , pp. 311-319
    • Henley, M.B.1    Meier, M.2    Tencer, A.F.3
  • 11
    • 0036142402 scopus 로고    scopus 로고
    • Modified tibial nails for treating distal tibia fractures
    • DOI 10.1097/00005131-200201000-00004
    • Gorczyca JT, McKale J, Pugh K, Pienkowski D. Modified tibial nails for treating distal tibia fractures. J Orthop Trauma. 2002;16: 18-22. (Pubitemid 34055934)
    • (2002) Journal of Orthopaedic Trauma , vol.16 , Issue.1 , pp. 18-22
    • Gorczyca, J.T.1    McKale, J.2    Pugh, K.3    Pienkowski, D.4
  • 12
    • 24644484024 scopus 로고    scopus 로고
    • Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing: Study of a displaced osteotomy model in sheep tibiae
    • DOI 10.2106/JBJS.D.02268
    • Kaspar K, Schell H, Seebeck P, et al. Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing. Study of a displaced osteotomy model in sheep tibiae. J Bone Joint Surg Am. 2005;87:2028-2037. (Pubitemid 41279135)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.I9 , pp. 2028-2037
    • Kaspar, K.1    Schell, H.2    Seebeck, P.3    Thompson, M.S.4    Schutz, M.5    Haas, N.P.6    Duda, G.N.7
  • 13
    • 66449103000 scopus 로고    scopus 로고
    • Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: A biomechanical study
    • Horn J, Linke B, Höntzsch D, Gueorguiev B, Schwieger K. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: A biomechanical study. Injury. 2009;40:767-771.
    • (2009) Injury. , vol.40 , pp. 767-771
    • Horn, J.1    Linke, B.2    Höntzsch, D.3    Gueorguiev, B.4    Schwieger, K.5
  • 14
    • 56349100149 scopus 로고    scopus 로고
    • Stiffness analysis of tibia-implant system under cyclic loading
    • Tschegg E, Herndler S, Weninger P, et al. Stiffness analysis of tibia-implant system under cyclic loading. Mater Sci Eng. 2008;28: 1203-1208.
    • (2008) Mater Sci Eng. , vol.28 , pp. 1203-1208
    • Tschegg, E.1    Herndler, S.2    Weninger, P.3
  • 15
    • 0031924426 scopus 로고    scopus 로고
    • Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants
    • DOI 10.1007/s005860050045
    • Wilke HJ, Wenger K, Claes L. Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J. 1998;7:148-154. (Pubitemid 28223601)
    • (1998) European Spine Journal , vol.7 , Issue.2 , pp. 148-154
    • Wilke, H.-J.1    Wenger, K.2    Claes, L.3
  • 16
    • 0036739510 scopus 로고    scopus 로고
    • Malrotation after locked intramedullary tibial nailing: Three case reports and review of the literature
    • Kahn KM, Beals RK. Malrotation after locked intramedullary tibial nailing: Three case reports and review of the literature. J Trauma. 2002;53:549-552.
    • (2002) J Trauma. , vol.53 , pp. 549-552
    • Kahn, K.M.1    Beals, R.K.2
  • 17
    • 33646828978 scopus 로고    scopus 로고
    • Treatment of distal tibia fractures without articular involvement: A systematic review of 1125 fractures
    • DOI 10.1097/01.bot.0000202997.45274.a1, PII 0000513120060100000018
    • Zelle BA, Bhandari M, Espiritu M, Koval KJ, Zlowodzki M; Evidence- Based Orthopaedic Trauma Working Group. Treatment of distal tibia fractures without articular involvement: A systematic review of 1125 fractures. J Orthop Trauma. 2006;20:76-79. (Pubitemid 44378203)
    • (2006) Journal of Orthopaedic Trauma , vol.20 , Issue.1 , pp. 76-79
    • Zelle, B.A.1    Bhandari, M.2    Espiritu, M.3    Koval, K.J.4    Zlowodzki, M.5
  • 18
    • 17044435463 scopus 로고    scopus 로고
    • Interlocking nails for displaced metaphyseal fractures of the distal tibia
    • Fan CY, Chiang CC, Chuang TY, Chiu FY, Chen TH. Interlocking nails for displaced metaphyseal fractures of the distal tibia. Injury. 2005;36:669-674.
    • (2005) Injury. , vol.36 , pp. 669-674
    • Fan, C.Y.1    Chiang, C.C.2    Chuang, T.Y.3    Chiu, F.Y.4    Chen, T.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.