메뉴 건너뛰기




Volumn 10, Issue 3, 2011, Pages 247-259

Enhancing the defect localization capability of a guided wave SHM system applied to a complex structure

Author keywords

complex structures; guided waves; imaging; structural health monitoring

Indexed keywords

COMPENSATION METHOD; COMPLEX STRUCTURE; CURRENT SIGNAL; DEFECT LOCALIZATIONS; DEFECT LOCATION; DEFECT-FREE; GATE LOCATION; GUIDED WAVE; GUIDED WAVES; IMAGING; MULTIPLE IMAGE; SHADOWING EFFECTS; SHIPPING CONTAINERS; STRUCTURAL HEALTH; STRUCTURAL HEALTH MONITORING SYSTEMS; TEMPERATURE COMPENSATION; TRANSDUCER ARRAY;

EID: 79951642727     PISSN: 14759217     EISSN: 17413168     Source Type: Journal    
DOI: 10.1177/1475921710373294     Document Type: Article
Times cited : (48)

References (33)
  • 1
    • 5444253931 scopus 로고    scopus 로고
    • Sparse ultrasonic transducer array for structural health monitoring
    • In: Thompson DO and Chimenti DE (eds)New York: American Institute of Physics
    • Michaels TE and Michaels JE Sparse ultrasonic transducer array for structural health monitoring. In: Thompson DO and Chimenti DE (eds) Review of progress in quantitative nondestructive evaluation. Vol. 23, New York: American Institute of Physics, 2004, pp.1468-1475.
    • (2004) Review of Progress in Quantitative Nondestructive Evaluation , vol.23 , pp. 1468-1475
    • Michaels, T.E.1    Michaels, J.E.2
  • 2
    • 34547395399 scopus 로고    scopus 로고
    • Active health monitoring of an aircraft wing with embedded piezoelectric sensor/actuator network: I. Defect detection, localization and growth monitoring
    • Zhao X., Gao H., Zhang G., Ayhan B., Yan F., Kwan C.,et al.Active health monitoring of an aircraft wing with embedded piezoelectric sensor/actuator network: I. Defect detection, localization and growth monitoring. Smart Mater Struct 2007; 16: 1208-1217.
    • (2007) Smart Mater Struct , vol.16 , pp. 1208-1217
    • Zhao, X.1    Gao, H.2    Zhang, G.3    Ayhan, B.4    Yan, F.5    Kwan, C.6
  • 3
    • 36048953801 scopus 로고    scopus 로고
    • Single mode tunning effects on Lamb wave time reversal with piezoelectric wafer active sensors for structural health monitoring
    • Xu B. and Giurgiutiu V. Single mode tunning effects on Lamb wave time reversal with piezoelectric wafer active sensors for structural health monitoring. J Nondestr Eval 2007; 26: 123-134.
    • (2007) J Nondestr Eval , vol.26 , pp. 123-134
    • Xu, B.1    Giurgiutiu, V.2
  • 4
    • 39449104478 scopus 로고    scopus 로고
    • Pitch-catch active sensing methods in structural health monitoring
    • Ihn J-B. and Chang F-K. Pitch-catch active sensing methods in structural health monitoring. SHM 2008; 7(1): 5-19.
    • (2008) SHM , vol.7 , Issue.1 , pp. 5-19
    • Ihn, J.-B.1    Chang, F.-K.2
  • 5
    • 0035360962 scopus 로고    scopus 로고
    • Structural health monitoring system based on diffracted Lamb wave analysis by multi-resolution processing
    • Lemistre M. and Balageas D. Structural health monitoring system based on diffracted Lamb wave analysis by multi-resolution processing. Smart Mater Struct 2001; 10: 504-511.
    • (2001) Smart Mater Struct , vol.10 , pp. 504-511
    • Lemistre, M.1    Balageas, D.2
  • 6
    • 1642617202 scopus 로고    scopus 로고
    • Health monitoring of a composite wingbox structure
    • Grondel S., Assad J., Delabarre C., and Moulin E. Health monitoring of a composite wingbox structure. Ultrasonics 2004; 42: 819-824.
    • (2004) Ultrasonics , vol.42 , pp. 819-824
    • Grondel, S.1    Assad, J.2    Delabarre, C.3    Moulin, E.4
  • 7
    • 33846847345 scopus 로고    scopus 로고
    • Time reversal active sensing for health monitoring of a composite plate
    • Park HW, Sohn H., Law KH, and Farrar CR Time reversal active sensing for health monitoring of a composite plate. J Sound Vib 2007; 302: 50-66.
    • (2007) J Sound Vib , vol.302 , pp. 50-66
    • Park, H.W.1    Sohn, H.2    Law, K.H.3    Farrar, C.R.4
  • 8
    • 76049092806 scopus 로고    scopus 로고
    • Guided wave health monitoring of complex structures by sparse array systems: influence of temperature changes on performance
    • Clarke T., Simonetti F., and Cawley P. Guided wave health monitoring of complex structures by sparse array systems: influence of temperature changes on performance. J Sound Vib 2010; 329(12): 2306-2322.
    • (2010) J Sound Vib , vol.329 , Issue.12 , pp. 2306-2322
    • Clarke, T.1    Simonetti, F.2    Cawley, P.3
  • 9
    • 73649147050 scopus 로고    scopus 로고
    • Evaluation of the damage detection capability of a sparse-array guided wave SHM system applied to a real structure
    • Clarke T., Cawley P., Wilcox P., and Croxford A. Evaluation of the damage detection capability of a sparse-array guided wave SHM system applied to a real structure. IEEE Trans Ultrason Ferroelectr Freq Control 2009; 56(12): 2666-2678.
    • (2009) IEEE Trans Ultrason Ferroelectr Freq Control , vol.56 , Issue.12 , pp. 2666-2678
    • Clarke, T.1    Cawley, P.2    Wilcox, P.3    Croxford, A.4
  • 11
    • 79955784599 scopus 로고    scopus 로고
    • Practical guided wave inspection and application to structural health monitoring
    • In: Proceedings of the 5th Australasian Congress on Applied Mechanics, Brisbane, Engineers Australia, Vol. 1
    • Cawley P. Practical guided wave inspection and application to structural health monitoring. In: Proceedings of the 5th Australasian Congress on Applied Mechanics, Brisbane, Engineers Australia, Vol. 1, 2007.
    • (2007)
    • Cawley, P.1
  • 12
    • 33646861493 scopus 로고    scopus 로고
    • An active diagnostic system for structural health monitoring of rocket engines
    • Qing XP, Chen H.-L, Beard SJ, and Kumar A. An active diagnostic system for structural health monitoring of rocket engines. J Intell Mater Syst Struct 2006; 17: 619-628.
    • (2006) J Intell Mater Syst Struct , vol.17 , pp. 619-628
    • Qing, X.P.1    Chen, H.2    Beard, S.J.3    Kumar, A.4
  • 13
    • 24144442483 scopus 로고    scopus 로고
    • Detection of structural damage from the local temporal coherence of diffuse ultrasonic signals
    • Michaels JE and Michaels TE Detection of structural damage from the local temporal coherence of diffuse ultrasonic signals. IEEE Trans Ultrason Ferroelectr Freq Control 2005; 52(10): 1769-1782.
    • (2005) IEEE Trans Ultrason Ferroelectr Freq Control , vol.52 , Issue.10 , pp. 1769-1782
    • Michaels, J.E.1    Michaels, T.E.2
  • 14
    • 36349001267 scopus 로고    scopus 로고
    • The fundamental axioms of structural health monitoring
    • Worden K., Farrar CR, Manson G., and Park G. The fundamental axioms of structural health monitoring. Proc R Soc A 2007; 463: 1639-1664.
    • (2007) Proc R Soc A , vol.463 , pp. 1639-1664
    • Worden, K.1    Farrar, C.R.2    Manson, G.3    Park, G.4
  • 15
    • 24144459831 scopus 로고    scopus 로고
    • A methodology for structural health monitoring with diffuse ultrasonic waves in the presence of temperature variations
    • Lu Y. and Michaels JE A methodology for structural health monitoring with diffuse ultrasonic waves in the presence of temperature variations. Ultrasonics 2005; 43: 717-731.
    • (2005) Ultrasonics , vol.43 , pp. 717-731
    • Lu, Y.1    Michaels, J.E.2
  • 17
    • 0033899434 scopus 로고    scopus 로고
    • Temperature dependence of diffuse field phase
    • Weaver RL and Lobkis OI Temperature dependence of diffuse field phase. Ultrasonics 2000; 38: 491-494.
    • (2000) Ultrasonics , vol.38 , pp. 491-494
    • Weaver, R.L.1    Lobkis, O.I.2
  • 18
    • 73649114424 scopus 로고    scopus 로고
    • Effects of liquid loading and degradation of adhesive joints on subtraction techniques for structural health monitoring
    • In: Thompson DO and Chimenti DE (eds)New York: American Institute of Physics
    • Cicero T., Cawley P., Lowe MJS, and Simonetti F. Effects of liquid loading and degradation of adhesive joints on subtraction techniques for structural health monitoring. In: Thompson DO and Chimenti DE (eds) Review of progress in quantitative nondestructive evaluation. Vol. 28: New York: American Institute of Physics, 2009, pp.1006-1013.
    • (2009) Review of Progress in Quantitative Nondestructive Evaluation , vol.28 , pp. 1006-1013
    • Cicero, T.1    Cawley, P.2    Lowe, M.J.S.3    Simonetti, F.4
  • 19
    • 65349102953 scopus 로고    scopus 로고
    • Simultaneous ultrasonic monitoring of crack growth and dynamic loads during full scale fatigue tests of aircraft wings
    • In: Thompson DO and Chimenti DE (eds)New York: American Institute of Physics
    • Michaels TE, Michaels JE, and Cobb AC Simultaneous ultrasonic monitoring of crack growth and dynamic loads during full scale fatigue tests of aircraft wings. In: Thompson DO and Chimenti DE (eds) Review of progress in quantitative nondestructive evaluation. Vol. 28: New York: American Institute of Physics, 2009, pp.1458-1465.
    • (2009) Review of Progress in Quantitative Nondestructive Evaluation , vol.28 , pp. 1458-1465
    • Michaels, T.E.1    Michaels, J.E.2    Cobb, A.C.3
  • 20
    • 44349092520 scopus 로고    scopus 로고
    • Quantification of environmental compensation strategies for guided wave structural health monitoring
    • In: Kundu T (ed.) Proceedings of SPIE, San Diego, USA
    • Croxford AJ, Wilcox PD, Lu Y., Michaels J., and Drinkwater BW Quantification of environmental compensation strategies for guided wave structural health monitoring. In: Kundu T (ed.) Proceedings of SPIE, San Diego, USA, Vol. 6935, H9350-H9350, 2008.
    • (2008) , vol.6935 , pp. 9350-9350
    • Croxford, A.J.1    Wilcox, P.D.2    Lu, Y.3    Michaels, J.4    Drinkwater, B.W.5
  • 21
    • 0012738252 scopus 로고    scopus 로고
    • The low frequency reflection characteristics of the fundamental antisymmetric Lamb wave a0 from a rectangular notch in a plate
    • Lowe MJS, Cawley P., Kao J-Y., and Diligent O. The low frequency reflection characteristics of the fundamental antisymmetric Lamb wave a0 from a rectangular notch in a plate. J Acoust Soc Am 2002; 112: 2612-2622.
    • (2002) J Acoust Soc Am , vol.112 , pp. 2612-2622
    • Lowe, M.J.S.1    Cawley, P.2    Kao, J.-Y.3    Diligent, O.4
  • 22
    • 0012229181 scopus 로고    scopus 로고
    • The low frequency reflection and scattering of the S0 Lamb mode from a circular through thickness hole in a plate: finite element, analytical and experimental studies
    • Diligent O., Grahn T., Bostrom A., Cawley P., and Lowe MJS. The low frequency reflection and scattering of the S0 Lamb mode from a circular through thickness hole in a plate: finite element, analytical and experimental studies. J Acoust Soc Am 2002; 112: 2589-2601.
    • (2002) J Acoust Soc Am , vol.112 , pp. 2589-2601
    • Diligent, O.1    Grahn, T.2    Bostrom, A.3    Cawley, P.4    Lowe, M.J.S.5
  • 23
    • 7644229506 scopus 로고    scopus 로고
    • Reflection of the S0 Lamb mode from a part-depth circular defect in a plate when the incident wave is created by a small source
    • In: Thompson DO and Chimenti DE (eds)New York: American Institute of Physics
    • Diligent O., Lowe MJS, Cawley P., and Wilcox P. Reflection of the S0 Lamb mode from a part-depth circular defect in a plate when the incident wave is created by a small source. In: Thompson DO and Chimenti DE (eds) Review of progress in quantitative nondestructive evaluation. Vol. 22, New York: American Institute of Physics, 2003, pp.197-204.
    • (2003) Review of Progress in Quantitative Nondestructive Evaluation , vol.22 , pp. 197-204
    • Diligent, O.1    Lowe, M.J.S.2    Cawley, P.3    Wilcox, P.4
  • 24
    • 0037380009 scopus 로고    scopus 로고
    • Scattering of the fundamental shear horizontal mode from steps and notches in plates
    • Demma A., Cawley P., and Lowe MJS. Scattering of the fundamental shear horizontal mode from steps and notches in plates. J Acoust Soc Am 2003; 113: 1880-1891.
    • (2003) J Acoust Soc Am , vol.113 , pp. 1880-1891
    • Demma, A.1    Cawley, P.2    Lowe, M.J.S.3
  • 25
    • 40849111724 scopus 로고    scopus 로고
    • A comparison of temperature compensation methods for guided wave structural health monitoring
    • In: Thompson DO and Chimenti DE (eds)New York: American Institute of Physics
    • Wilcox PD, Croxford AJ, Michaels JE, Lu Y., and Drinkwater BW A comparison of temperature compensation methods for guided wave structural health monitoring. In: Thompson DO and Chimenti DE (eds) Review of progress in quantitative nondestructive evaluation. Vol. 27, New York: American Institute of Physics, 2008, pp.1453-1460.
    • (2008) Review of Progress in Quantitative Nondestructive Evaluation , vol.27 , pp. 1453-1460
    • Wilcox, P.D.1    Croxford, A.J.2    Michaels, J.E.3    Lu, Y.4    Drinkwater, B.W.5
  • 26
    • 33748519607 scopus 로고    scopus 로고
    • Guided wave tomography on an aircraft wing with leave in place sensors
    • In: Thompson DO and Chimenti DE (eds)New York: American Institute of Physics
    • Gao H., Shi Y., and Rose JL Guided wave tomography on an aircraft wing with leave in place sensors. In: Thompson DO and Chimenti DE (eds) Review of progress in quantitative nondestructive evaluation. Vol. 760, New York: American Institute of Physics, 2005, pp.1788-1794.
    • (2005) Review of Progress in Quantitative Nondestructive Evaluation , vol.760 , pp. 1788-1794
    • Gao, H.1    Shi, Y.2    Rose, J.L.3
  • 27
    • 35648983375 scopus 로고    scopus 로고
    • Strategies for overcoming the effect of temperature on guided wave structural health monitoring
    • In: Proceeding of SPIE, San Diego, USA
    • Croxford AJ, Wilcox PD, Konstantinidis G., and Drinkwater BW Strategies for overcoming the effect of temperature on guided wave structural health monitoring. In: Proceeding of SPIE, San Diego, USA, Vol. 6532T, 2007, pp.11-19.
    • (2007) , vol.6532 , pp. 11-19
    • Croxford, A.J.1    Wilcox, P.D.2    Konstantinidis, G.3    Drinkwater, B.W.4
  • 28
    • 2142772678 scopus 로고    scopus 로고
    • A synthetic time-reversal imaging method for structural health monitoring
    • Wang CH, Rose JL, and Chang F.-K. A synthetic time-reversal imaging method for structural health monitoring. Smart Mater Struct 2004; 13: 415-423.
    • (2004) Smart Mater Struct , vol.13 , pp. 415-423
    • Wang, C.H.1    Rose, J.L.2    Chang, F.K.3
  • 29
    • 34547395399 scopus 로고    scopus 로고
    • Active health monitoring of an aircraft wing with embedded piezoelectric sensor/actuator network: I. Defect detection, localization and growth monitoring
    • Zhao X., Gao H., Zhang G., Ayhan B., Yan F., Kwan C.,et al.Active health monitoring of an aircraft wing with embedded piezoelectric sensor/actuator network: I. Defect detection, localization and growth monitoring. Smart Mater Struct 2007; 16: 1208-1217.
    • (2007) Smart Mater Struct , vol.16 , pp. 1208-1217
    • Zhao, X.1    Gao, H.2    Zhang, G.3    Ayhan, B.4    Yan, F.5    Kwan, C.6
  • 30
    • 45749126556 scopus 로고    scopus 로고
    • Detection, localization and characterization of damage in plates with an in situ array of spatially distributed ultrasonic sensors
    • Michaels J. Detection, localization and characterization of damage in plates with an in situ array of spatially distributed ultrasonic sensors. Smart Mater Struct 2008; 17: 035035.
    • (2008) Smart Mater Struct , vol.17 , pp. 035035
    • Michaels, J.1
  • 31
    • 78649757615 scopus 로고    scopus 로고
    • Imaging algorithms for locating damage via in situ ultrasonic sensors
    • Atlanta, GA, USA
    • Michaels JE, Croxford AJ, and Wilcox PD Imaging algorithms for locating damage via in situ ultrasonic sensors. In: IEEE Sensors Application Symposium, Atlanta, GA, USA, 2008, pp.63-67.
    • (2008) IEEE Sensors Application Symposium , pp. 63-67
    • Michaels, J.E.1    Croxford, A.J.2    Wilcox, P.D.3
  • 32
    • 77953517802 scopus 로고    scopus 로고
    • Structural health monitoring of stiffened plates using guided ultrasonic waves
    • In: Thompson DO and Chimenti DE (eds)New York: American Institute of Physics
    • Fromme P. Structural health monitoring of stiffened plates using guided ultrasonic waves. In: Thompson DO and Chimenti DE (eds) Review of progress in quantitative nondestructive evaluation. Vol. 27, New York: American Institute of Physics, 2008, pp.78-85.
    • (2008) Review of Progress in Quantitative Nondestructive Evaluation , vol.27 , pp. 78-85
    • Fromme, P.1
  • 33
    • 34249904418 scopus 로고    scopus 로고
    • Guided wave signal processing and image fusion for in situ damage localization in plates
    • Michaels JE and Michaels TE Guided wave signal processing and image fusion for in situ damage localization in plates. Wave Motion 2007; 44: 482-492.
    • (2007) Wave Motion , vol.44 , pp. 482-492
    • Michaels, J.E.1    Michaels, T.E.2