메뉴 건너뛰기




Volumn 25, Issue 2, 2011, Pages 168-173

The UK national cyclodiode laser survey

Author keywords

ciliary body; glaucoma; laser coagulation; raised intraocular pressure

Indexed keywords

ARTICLE; CATARACT EXTRACTION; GLAUCOMA; HEALTH CARE SURVEY; HUMAN; LASER COAGULATION; MEDICAL PRACTICE; POSTOPERATIVE CARE; QUESTIONNAIRE; SURGICAL TECHNIQUE; TRANSSCLERAL DIODE LASER CYCLOPHOTOCOAGULATION; UNITED KINGDOM; UVEITIS; VISUAL ACUITY;

EID: 79951564770     PISSN: 0950222X     EISSN: 14765454     Source Type: Journal    
DOI: 10.1038/eye.2010.174     Document Type: Article
Times cited : (28)

References (25)
  • 1
    • 0000294325 scopus 로고
    • Cyclodiathermypuncture in cases of glaucoma
    • Vogt A. Cyclodiathermypuncture in cases of glaucoma. Br J Ophthalmol 1940; 24: 288-297.
    • (1940) Br J Ophthalmol , vol.24 , pp. 288-297
    • Vogt, A.1
  • 2
    • 0000898231 scopus 로고
    • Surgical intervention on the ciliary body; New trends for the relief of glaucoma
    • Bietti G. Surgical intervention on the ciliary body; new trends for the relief of glaucoma. JAMA 1950; 142: 889-897.
    • (1950) JAMA , vol.142 , pp. 889-897
    • Bietti, G.1
  • 3
    • 0025345589 scopus 로고
    • Evaluation of a protocol for transscleral neodymium: YAG cyclophotocoagulation in one hundred patients
    • Hampton C, Shields MB, Miller KN, Blasini M. Evaluation of a protocol for trans-scleral neodymium: YAG cyclophotocoagulation in one hundred patients. Ophthalmology 1990; 97: 910-917. (Pubitemid 20217942)
    • (1990) Ophthalmology , vol.97 , Issue.7 , pp. 910-917
    • Hampton, C.1    Shields, M.B.2    Miller, K.N.3    Blasini, M.4
  • 4
    • 0025198450 scopus 로고
    • Trans-scleral application of semiconductor diode laser
    • Peyman GA, Naguib KS, Gaasterland D. Trans-scleral application of semiconductor diode laser. Lasers Surg Med 1990; 10: 569-575.
    • (1990) Lasers Surg Med , vol.10 , pp. 569-575
    • Peyman, G.A.1    Naguib, K.S.2    Gaasterland, D.3
  • 5
    • 0025748614 scopus 로고
    • A comparison of neodymium:Yttrium aluminium garnet and diode laser trans-scleral cyclophotocoagulation and cyclocryotherapy
    • Assia EI, Hennis HL, Stewart WC, Legler UF, Carlson AN, Apple DJ. A comparison of neodymium:yttrium aluminium garnet and diode laser trans-scleral cyclophotocoagulation and cyclocryotherapy. Invest Ophthalmol Vis Sci 1991; 32: 2774-2778.
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 2774-2778
    • Assia, E.I.1    Hennis, H.L.2    Stewart, W.C.3    Legler, U.F.4    Carlson, A.N.5    Apple, D.J.6
  • 6
    • 0026598752 scopus 로고
    • Semiconductor diode laser trans-scleral cyclophotocoagulation in patients with glaucoma
    • Hennis HL, Stewart WC. Semiconductor diode laser trans-scleral cyclophotocoagulation in patients with glaucoma. Am J Ophthalmol 1992; 113: 81-85.
    • (1992) Am J Ophthalmol , vol.113 , pp. 81-85
    • Hennis, H.L.1    Stewart, W.C.2
  • 7
    • 0026075101 scopus 로고
    • Energy levels and probe placement in contact transscleral semiconductor diode laser cyclophotocoagulation in human cadaver eyes
    • Schuman JS, Noecker RJ, Puliafito CA, Jacobson JJ, Shepps GJ, Wang N. Energy levels and probe placement in contact transscleral semiconductor diode laser cyclophotocoagulation in human cadaver eyes. Arch Ophthalmol 1991; 109: 1534-1538.
    • (1991) Arch Ophthalmol , vol.109 , pp. 1534-1538
    • Schuman, J.S.1    Noecker, R.J.2    Puliafito, C.A.3    Jacobson, J.J.4    Shepps, G.J.5    Wang, N.6
  • 8
    • 0025831279 scopus 로고
    • Transscleral cyclophotocoagulation using a semiconductor diode laser in cadaver eyes
    • Hennis HL, Assia E, Stewart WC, Legler UF, Apple DJ. Transscleral cyclophotocoagulation using a semiconductor diode laser in cadaver eyes. Ophthalmic Surg 1991; 22: 274-278.
    • (1991) Ophthalmic Surg , vol.22 , pp. 274-278
    • Hennis, H.L.1    Assia, E.2    Stewart, W.C.3    Legler, U.F.4    Apple, D.J.5
  • 9
    • 0141525369 scopus 로고    scopus 로고
    • A two centre study of the dose-response relation for transscleral diode laser cyclophotocoagulation in refractory glaucoma
    • DOI 10.1136/bjo.87.10.1252
    • Murphy CC, Burnett CA, Spry PG, Broadway DC, Diamond JP. A two centre study of the dose-response relation for transscleral diode laser cyclophotocoagulation in refractory glaucoma. Br J Ophthalmol 2003; 87: 1252-1257. (Pubitemid 37193917)
    • (2003) British Journal of Ophthalmology , vol.87 , Issue.10 , pp. 1252-1257
    • Murphy, C.C.1    Burnett, C.A.M.2    Spry, P.G.D.3    Broadway, D.C.4    Diamond, J.P.5
  • 10
    • 0033057148 scopus 로고    scopus 로고
    • Cyclodiode results of a standard protocol
    • Spencer AF, Vernon SA. Cyclodiode results of a standard protocol. Br J Ophthalmol 1999; 83: 311-316.
    • (1999) Br J Ophthalmol , vol.83 , pp. 311-316
    • Spencer, A.F.1    Vernon, S.A.2
  • 12
    • 0025282525 scopus 로고
    • Probe placement and power levels in contact transscleral neodymium:YAG cyclophotocoagulation
    • Allingham RR, de Kater AW, Bellows AR, Hsu J. Probe placement and power levels in contract trans-scleral neodymium:YAG cyclophotocoagulation. Arch Ophthalmol 1990; 108: 738-742. (Pubitemid 20168838)
    • (1990) Archives of Ophthalmology , vol.108 , Issue.5 , pp. 738-742
    • Allingham, R.R.1    De Kater, A.W.2    Bellows, A.R.3    Hsu, J.4
  • 13
    • 0024554486 scopus 로고
    • A technique for precise placement of laser applications in transscleral Nd:YAG cyclophotocoagulation
    • Fiore PM, Latina MA. A technique for precise placement of laser applications in transscleral Nd:YAG cyclophotocoagulation. Am J Ophthalmol 1989; 107: 292-293. (Pubitemid 19073681)
    • (1989) American Journal of Ophthalmology , vol.107 , Issue.3 , pp. 292-293
    • Fiore, P.M.1    Latina, M.A.2
  • 14
    • 65349104723 scopus 로고    scopus 로고
    • Ciliary body position variability in glaucoma patients assessed by scleral transillumination
    • Agrawal P, Martin KR. Ciliary body position variability in glaucoma patients assessed by scleral transillumination. Eye 2008; 22: 1499-1503.
    • (2008) Eye , vol.22 , pp. 1499-1503
    • Agrawal, P.1    Martin, K.R.2
  • 15
    • 0029922301 scopus 로고    scopus 로고
    • Endoscopic flourescein angiography of the ciliary body in glaucoma management
    • Uram M. Endoscopic flourescein angiography of the ciliary body in glaucoma management. Ophthalmic Surg Lasers 1996; 27: 174-178.
    • (1996) Ophthalmic Surg Lasers , vol.27 , pp. 174-178
    • Uram, M.1
  • 16
    • 0343831919 scopus 로고    scopus 로고
    • Audible pops during cyclodiode procedures
    • Rebolleda G, Munoz FJ, Murube J. Audible pops during cyclodiode procedures. J Glaucoma 1999; 8: 177-183. (Pubitemid 32435876)
    • (1999) Journal of Glaucoma , vol.8 , Issue.3 , pp. 177-183
    • Rebolleda, G.1    Munoz, F.J.2    Murube, J.3
  • 17
    • 40949154808 scopus 로고    scopus 로고
    • Lower energy levels adequate for effective transcleral diode laser cyclophotocoagulation in Asian eyes with refractory glaucoma
    • DOI 10.1038/sj.eye.6702653, PII 6702653
    • Kaushik A, Pandav SS, Jain R, Bansal S, Gupta A. Lower energy levels adequate for effective transscleral diode laser cyclophotocoagulation in Asian eyes with refractory glaucoma. Eye 2008; 22: 398-405. (Pubitemid 351404466)
    • (2008) Eye , vol.22 , Issue.3 , pp. 398-405
    • Kaushik, S.1    Pandav, S.S.2    Jain, R.3    Bansal, S.4    Gupta, A.5
  • 18
    • 33745869710 scopus 로고    scopus 로고
    • Diode laser cycloablation in adult glaucoma: Long-term results of a standard protocol and review of current literature
    • DOI 10.1111/j.1442-9071.2006.01241.x
    • Vernon SA, Koppens JM, Menon GJ, Negi AK. Diode laser cycloablation in adult glaucoma: long-term results of a standard protocol and review of current literature. Clin Experiment Ophthalmol 2006; 34: 411-420. (Pubitemid 44027226)
    • (2006) Clinical and Experimental Ophthalmology , vol.34 , Issue.5 , pp. 411-420
    • Vernon, S.A.1    Koppens, J.M.2    Menon, G.J.3    Negi, A.K.4
  • 20
    • 79951562161 scopus 로고
    • The ciliary body
    • Leon C, Leon J (eds). Medsi/Mcgraw-Hill: Paris, France
    • Leon C, Leon J. The ciliary body. In: Leon C, Leon J (eds). Endoscopic Chirurgicale Oculaire. Medsi/Mcgraw-Hill: Paris, France, 1990, pp 42-47.
    • (1990) Endoscopic Chirurgicale Oculaire , pp. 42-47
    • Leon, C.1    Leon, J.2
  • 21
    • 0027095992 scopus 로고
    • Initial experience with a new method of laser transscleral cyclophotocoagulation for ciliary ablation in severe glaucoma
    • Gaasterland DE, Pollack IP. Initial experience with a new method of laser transscleral cyclophotocoagulation for ciliary ablation in severe glaucoma. Trans Am Ophthalmol Soc 1992; 90: 225-243.
    • (1992) Trans Am Ophthalmol Soc , vol.90 , pp. 225-243
    • Gaasterland, D.E.1    Pollack, I.P.2
  • 22
    • 0029841073 scopus 로고    scopus 로고
    • Long-term outcome of initial ciliary ablation with contact diode laser transscleral cyclophotocoagulation for severe glaucoma
    • Kosoko O, Gaasterland DE, Pollack IP, Enger CL. The Diode Laser Ciliary Ablation Study Group. Long-term outcome of initial ciliary ablation with contact diode laser transscleral cyclophotocoagulation for severe glaucoma. Ophthalmology 1996; 103: 1294-1302. (Pubitemid 26282514)
    • (1996) Ophthalmology , vol.103 , Issue.8 , pp. 1294-1302
    • Kosoko, O.1    Gaasterland, D.E.2    Pollack, I.P.3    Enger, C.L.4
  • 23
    • 0000138312 scopus 로고    scopus 로고
    • Five-year follow-up of the fluorouracil filtering surgery study
    • The Fluorouracil Filtering Surgery Study Group
    • Five-year follow-up of the Fluorouracil Filtering Surgery Study. The Fluorouracil Filtering Surgery Study Group. Am J Ophthalmol 1996; 121: 349-366.
    • (1996) Am J Ophthalmol , vol.121 , pp. 349-366


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.