-
1
-
-
0014973737
-
Newer materials and techniques in prosthetic resin materials
-
Woelfel JB. Newer materials and techniques in prosthetic resin materials. Dent Clin North Am 1971; 15: 67-79.
-
(1971)
Dent Clin North Am
, vol.15
, pp. 67-79
-
-
Woelfel, J.B.1
-
2
-
-
0024762618
-
Resin denture bases: Review of accuracy and methods of polymerization
-
Takamata T, Setcos JC. Resin denture bases: review of accuracy and methods of polymerization. Int J Prosthodont 1989; 2: 555-562.
-
(1989)
Int J Prosthodont
, vol.2
, pp. 555-562
-
-
Takamata, T.1
Setcos, J.C.2
-
4
-
-
0025515361
-
Effects of denture teeth on the dimensional accuracy of acrylic resin denture bases
-
Baemmert RJ, Lang BR, Barco MT, Jr., Billy EJ. Effects of denture teeth on the dimensional accuracy of acrylic resin denture bases. Int J Prosthodont 1990; 3: 528-537.
-
(1990)
Int J Prosthodont
, vol.3
, pp. 528-537
-
-
Baemmert, R.J.1
Lang, B.R.2
Barco Jr., M.T.3
Billy, E.J.4
-
5
-
-
0027622687
-
The influence of teeth on denture base processing accuracy
-
Jackson AD, Lang BR, Wang RF. The influence of teeth on denture base processing accuracy. Int J Prosthodont 1993; 6: 333-340.
-
(1993)
Int J Prosthodont
, vol.6
, pp. 333-340
-
-
Jackson, A.D.1
Lang, B.R.2
Wang, R.F.3
-
6
-
-
0020984549
-
Evaluation of dimensional changes in complete dentures processed by injection-pressing and the pack-andpress technique
-
Garfunkel E. Evaluation of dimensional changes in complete dentures processed by injection-pressing and the pack-andpress technique. J Prosthet Dent 1983; 50: 757-761.
-
(1983)
J Prosthet Dent
, vol.50
, pp. 757-761
-
-
Garfunkel, E.1
-
7
-
-
0002387805
-
Dimensional accuracy of various denture-base materials
-
Anthony DH, Peyton FA. Dimensional accuracy of various denture-base materials. J Prosthet Dent 1962; 12: 67-81.
-
(1962)
J Prosthet Dent
, vol.12
, pp. 67-81
-
-
Anthony, D.H.1
Peyton, F.A.2
-
8
-
-
0034626005
-
The physical mechanisms of complete denture retention
-
Darvell BW, Clark RK. The physical mechanisms of complete denture retention. Br Dent J 2000; 189: 248-252.
-
(2000)
Br Dent J
, vol.189
, pp. 248-252
-
-
Darvell, B.W.1
Clark, R.K.2
-
9
-
-
0142199087
-
Injection molding of plastics for dentures
-
Pryor WJ. Injection molding of plastics for dentures. J Am Dent Assoc 1942; 29: 1400-1408.
-
(1942)
J Am Dent Assoc
, vol.29
, pp. 1400-1408
-
-
Pryor, W.J.1
-
10
-
-
0014072561
-
The fluid resin technique of denture base formation
-
Fairchild JM. The fluid resin technique of denture base formation. J Calif Dent Assoc 1967; 43: 127-128.
-
(1967)
J Calif Dent Assoc
, vol.43
, pp. 127-128
-
-
Fairchild, J.M.1
-
11
-
-
0024709169
-
Adaptation of acrylic resin dentures as influenced by the activation mode of polymerization
-
Takamata T, Setcos JC, Phillips RW, Boone ME. Adaptation of acrylic resin dentures as influenced by the activation mode of polymerization. J Am Dent Assoc 1989; 119: 271-276.
-
(1989)
J Am Dent Assoc
, vol.119
, pp. 271-276
-
-
Takamata, T.1
Setcos, J.C.2
Phillips, R.W.3
Boone, M.E.4
-
12
-
-
0027343697
-
Posterior palatal seal adaptation: Influence of processing technique, palate shape and immersion
-
Sykora O, Sutow EJ. Posterior palatal seal adaptation: influence of processing technique, palate shape and immersion. J Oral Rehabil 1993; 20: 19-31.
-
(1993)
J Oral Rehabil
, vol.20
, pp. 19-31
-
-
Sykora, O.1
Sutow, E.J.2
-
13
-
-
0035751231
-
A comparison of palatal adaptation in acrylic resin denture bases using conventional and anchored polymerization techniques
-
Laughlin GA, Eick JD, Glaros AG, Young L, Moore DJ. A comparison of palatal adaptation in acrylic resin denture bases using conventional and anchored polymerization techniques. J Prosthodont 2001; 10: 204-211.
-
(2001)
J Prosthodont
, vol.10
, pp. 204-211
-
-
Laughlin, G.A.1
Eick, J.D.2
Glaros, A.G.3
Young, L.4
Moore, D.J.5
-
15
-
-
0036731266
-
Effect of a new tension system, used in acrylic resin flasking, on the dimensional stability of denture bases
-
Consani RL, Domitti SS, Consani S. Effect of a new tension system, used in acrylic resin flasking, on the dimensional stability of denture bases. J Prosthet Dent 2002; 88: 285-289.
-
(2002)
J Prosthet Dent
, vol.88
, pp. 285-289
-
-
Consani, R.L.1
Domitti, S.S.2
Consani, S.3
-
16
-
-
10044284354
-
Dimensional accuracy of acrylic resin maxillary denture base polymerized by a new injection pressing method
-
Ono T, Kita S, Nokubi T. Dimensional accuracy of acrylic resin maxillary denture base polymerized by a new injection pressing method. Dent Mater J 2004; 23: 348-352.
-
(2004)
Dent Mater J
, vol.23
, pp. 348-352
-
-
Ono, T.1
Kita, S.2
Nokubi, T.3
-
18
-
-
0018499166
-
The effect of relining on the accuracy and stability of maxillary complete dentures--an in vitro and in vivo study
-
Barco MT Jr, Moore BK, Swartz ML, Boone ME, Dykema RW, Phillips RW. The effect of relining on the accuracy and stability of maxillary complete dentures--an in vitro and in vivo study. J Prosthet Dent 1979; 42: 17-22.
-
(1979)
J Prosthet Dent
, vol.42
, pp. 17-22
-
-
Barco Jr., M.T.1
Moore, B.K.2
Swartz, M.L.3
Boone, M.E.4
Dykema, R.W.5
Phillips, R.W.6
-
19
-
-
47949104745
-
Cumulative effect of disinfection procedures on microhardness and tridimensional stability of a poly(methyl methacrylate) denture base resin
-
Sartori EA, Schmidt CB, Mota EG, Hirakata LM, Shinkai RS. Cumulative effect of disinfection procedures on microhardness and tridimensional stability of a poly(methyl methacrylate) denture base resin. J Biomed Mater Res B 2008; 86: 360-364.
-
(2008)
J Biomed Mater Res B
, vol.86
, pp. 360-364
-
-
Sartori, E.A.1
Schmidt, C.B.2
Mota, E.G.3
Hirakata, L.M.4
Shinkai, R.S.5
-
20
-
-
0035495581
-
A pilot clinical evaluation of a new injection denture base system
-
Haug SP, Duke P, Dixon SE, Menegotto LD, Zentz RR, Moore BK. A pilot clinical evaluation of a new injection denture base system. Compend Contin Educ Dent 2001; 22: 847-852, 854, 856.
-
(2001)
Compend Contin Educ Dent
, vol.22
-
-
Haug, S.P.1
Duke, P.2
Dixon, S.E.3
Menegotto, L.D.4
Zentz, R.R.5
Moore, B.K.6
-
21
-
-
0017483395
-
The comparison of denture-base processing techniques. Part II. Dimensional changes due to processing
-
Becker CM, Smith DE, Nicholls JI. The comparison of denture-base processing techniques. Part II. Dimensional changes due to processing. J Prosthet Dent 1977; 37: 450-459.
-
(1977)
J Prosthet Dent
, vol.37
, pp. 450-459
-
-
Becker, C.M.1
Smith, D.E.2
Nicholls, J.I.3
-
24
-
-
79951502448
-
Adaptation and Stability of Denture Bases Processed by means of an Induction-heating Technique
-
Matsumura H, Taira Y, Yoshida K, Tanaka T, Atsuta M. Adaptation and Stability of Denture Bases Processed by means of an Induction-heating Technique. J Jap Prosthodont Soc 1995; 39: 511-516.
-
(1995)
J Jap Prosthodont Soc
, vol.39
, pp. 511-516
-
-
Matsumura, H.1
Taira, Y.2
Yoshida, K.3
Tanaka, T.4
Atsuta, M.5
-
25
-
-
0031066082
-
Improved fit of maxillary complete dentures processed on high expansion stone casts
-
Sykora O, Sutow EJ. Improved fit of maxillary complete dentures processed on high expansion stone casts. J Prosthet Dent 1997; 77: 205-208.
-
(1997)
J Prosthet Dent
, vol.77
, pp. 205-208
-
-
Sykora, O.1
Sutow, E.J.2
-
26
-
-
0347479305
-
Dimensional stability and dehydration of a thermoplastic polycarbonate-based and two PMMA-based denture resins
-
Pronych GJ, Sutow EJ, Sykora O. Dimensional stability and dehydration of a thermoplastic polycarbonate-based and two PMMA-based denture resins. J Oral Rehabil 2003; 30: 1157-1161.
-
(2003)
J Oral Rehabil
, vol.30
, pp. 1157-1161
-
-
Pronych, G.J.1
Sutow, E.J.2
Sykora, O.3
-
27
-
-
0024661515
-
Moire topography for measuring the dimensional accuracy of resin complete denture bases
-
Frejlich S, Dirckx JJ, Goodacre CJ, Swartz ML, Andres CJ. Moire topography for measuring the dimensional accuracy of resin complete denture bases. Int J Prosthodont 1989; 2: 272-279.
-
(1989)
Int J Prosthodont
, vol.2
, pp. 272-279
-
-
Frejlich, S.1
Dirckx, J.J.2
Goodacre, C.J.3
Swartz, M.L.4
Andres, C.J.5
-
28
-
-
0024812029
-
Comparison of changes in vertical dimension between compression and injection molded complete denture
-
Strohaver RA. Comparison of changes in vertical dimension between compression and injection molded complete denture. J Prosthet Dent 1989; 62: 716-718.
-
(1989)
J Prosthet Dent
, vol.62
, pp. 716-718
-
-
Strohaver, R.A.1
-
29
-
-
0033192648
-
Comparison of accuracy between compression- and injection-molded complete dentures
-
Nogueira SS, Ogle RE, Davis EL. Comparison of accuracy between compression- and injection-molded complete dentures. J Prosthet Dent 1999; 82: 291-300.
-
(1999)
J Prosthet Dent
, vol.82
, pp. 291-300
-
-
Nogueira, S.S.1
Ogle, R.E.2
Davis, E.L.3
-
30
-
-
0037608739
-
Dimensional change in complete dentures fabricated by injection molding and microwave processing
-
Keenan PL, Radford DR, Clark RK. Dimensional change in complete dentures fabricated by injection molding and microwave processing. J Prosthet Dent 2003; 89: 37-44.
-
(2003)
J Prosthet Dent
, vol.89
, pp. 37-44
-
-
Keenan, P.L.1
Radford, D.R.2
Clark, R.K.3
-
31
-
-
0026872136
-
Relative fit of new denture resins polymerized by heat, light and microwave energy
-
Smith LT, Powers JM. Relative fit of new denture resins polymerized by heat, light and microwave energy. Am J Dent 1992; 5: 140-142.
-
(1992)
Am J Dent
, vol.5
, pp. 140-142
-
-
Smith, L.T.1
Powers, J.M.2
-
32
-
-
0017468445
-
The comparison of denture-base processing techniques. Part I. Material characteristics
-
Becker CM, Smith DE, Nicholls JI. The comparison of denture-base processing techniques. Part I. Material characteristics. J Prosthet Dent 1977; 37: 330-338.
-
(1977)
J Prosthet Dent
, vol.37
, pp. 330-338
-
-
Becker, C.M.1
Smith, D.E.2
Nicholls, J.I.3
-
34
-
-
34347342665
-
Internal adaptation and some physical properties of methacrylate-based denture base resins polymerized by different techniques
-
Ganzarolli SM, de Mello JA, Shinkai RS, Del Bel Cury AA. Internal adaptation and some physical properties of methacrylate-based denture base resins polymerized by different techniques. J Biomed Mater Res B 2007; 82: 169-173.
-
(2007)
J Biomed Mater Res B
, vol.82
, pp. 169-173
-
-
Ganzarolli, S.M.1
de Mello, J.A.2
Shinkai, R.S.3
Del Bel Cury, A.A.4
-
35
-
-
60649116074
-
Contemporary techniques for denture fabrication
-
McCord JF. Contemporary techniques for denture fabrication. J Prosthodont 2009; 18: 106-111.
-
(2009)
J Prosthodont
, vol.18
, pp. 106-111
-
-
McCord, J.F.1
-
36
-
-
74249089843
-
Micro-CT evaluation of the marginal fit of different In- Ceram alumina copings
-
Pelekanos S, Koumanou M, Koutayas SO, Zinelis S, Eliades G. Micro-CT evaluation of the marginal fit of different In- Ceram alumina copings. Eur J Esthet Dent 2009; 4: 278-292.
-
(2009)
Eur J Esthet Dent
, vol.4
, pp. 278-292
-
-
Pelekanos, S.1
Koumanou, M.2
Koutayas, S.O.3
Zinelis, S.4
Eliades, G.5
|