메뉴 건너뛰기




Volumn 4, Issue 3, 2011, Pages 417-422

Fatigue endurance of Ti-6Al-4V alloy with electro-eroded surface for improved bone in-growth

Author keywords

Bone in growth; Electric discharge machining; Fatigue endurance

Indexed keywords

CRACK NUCLEATION; DUPLEX MICROSTRUCTURES; ELECTROPOLISHED; FATIGUE ENDURANCES; FATIGUE-CRACK NUCLEATION; HIGH CYCLE FATIGUE; HIGH-PEAK CURRENTS; MICROCRACK GROWTH; MICROSTRUCTURAL EFFECT; NOTCH SENSITIVITY; OSTEOINTEGRATION; RESIDUAL TENSILE STRESS; ROTATING BEAM; SEM; TI-6AL-4V; TI-6AL-4V ALLOY;

EID: 79751536256     PISSN: 17516161     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jmbbm.2010.12.001     Document Type: Article
Times cited : (43)

References (24)
  • 1
    • 0011173192 scopus 로고    scopus 로고
    • Phase transformations during cooling in α+β titanium alloys
    • Ahmed T., Rack H.J. Phase transformations during cooling in α+β titanium alloys. Mater. Sci. Eng. A 1998, 243:206-211.
    • (1998) Mater. Sci. Eng. A , vol.243 , pp. 206-211
    • Ahmed, T.1    Rack, H.J.2
  • 2
    • 0036533256 scopus 로고    scopus 로고
    • Improvement in the morphology of Ti-based surfaces: a new process to increase in vitro human osteoblast response
    • Bigerelle M., Anselme K., Noel B., Ruderman I., Hardouin P., Iost A. Improvement in the morphology of Ti-based surfaces: a new process to increase in vitro human osteoblast response. Biomaterials 2002, 23:1563-1577.
    • (2002) Biomaterials , vol.23 , pp. 1563-1577
    • Bigerelle, M.1    Anselme, K.2    Noel, B.3    Ruderman, I.4    Hardouin, P.5    Iost, A.6
  • 3
    • 65549114954 scopus 로고    scopus 로고
    • Comparative in vivo evaluation of porous and dense duplex titanium and hydroxyapatite coatings with high roughnesses in different implantation environments
    • Borsari V., Fini M., Giaversi G., Tschon M., Chiesa R., Chiusoli L., Salito A., Rimondini L., Giardino R. Comparative in vivo evaluation of porous and dense duplex titanium and hydroxyapatite coatings with high roughnesses in different implantation environments. J. Biomed. Mater. Res. Part A 2009, 89:550-560.
    • (2009) J. Biomed. Mater. Res. Part A , vol.89 , pp. 550-560
    • Borsari, V.1    Fini, M.2    Giaversi, G.3    Tschon, M.4    Chiesa, R.5    Chiusoli, L.6    Salito, A.7    Rimondini, L.8    Giardino, R.9
  • 5
    • 84875686716 scopus 로고    scopus 로고
    • Ti based biomaterials, the ultimate choice for orthopaedic implants-a review
    • Geetha M., Singh A.K., Asokamani R., Gogia A.K. Ti based biomaterials, the ultimate choice for orthopaedic implants-a review. Prog. Mater. Sci. 2009, 54:397-425.
    • (2009) Prog. Mater. Sci. , vol.54 , pp. 397-425
    • Geetha, M.1    Singh, A.K.2    Asokamani, R.3    Gogia, A.K.4
  • 6
    • 29144451919 scopus 로고    scopus 로고
    • Physical and biological characterizations of a novel multiphase anodic spark deposition coating to enhance implant osseointegration
    • Giordano C., Chiesa R., Sandrini E., Cigada A., Giavaresi G., Fini M., Giardino R. Physical and biological characterizations of a novel multiphase anodic spark deposition coating to enhance implant osseointegration. J. Mater. Sci., Mater. Med. 2005, 16:1221-1229.
    • (2005) J. Mater. Sci., Mater. Med. , vol.16 , pp. 1221-1229
    • Giordano, C.1    Chiesa, R.2    Sandrini, E.3    Cigada, A.4    Giavaresi, G.5    Fini, M.6    Giardino, R.7
  • 7
    • 34547834202 scopus 로고    scopus 로고
    • Electrical discharge machining of titanium alloy
    • Hascalik A., Caydas U. Electrical discharge machining of titanium alloy. Appl. Surf. Sci. 2007, 253:9007-9016.
    • (2007) Appl. Surf. Sci. , vol.253 , pp. 9007-9016
    • Hascalik, A.1    Caydas, U.2
  • 8
    • 9144249321 scopus 로고    scopus 로고
    • Biomaterials in total joint replacement
    • Katti K.S. Biomaterials in total joint replacement. Colloids. Surf. B 2004, 39:133-142.
    • (2004) Colloids. Surf. B , vol.39 , pp. 133-142
    • Katti, K.S.1
  • 9
    • 0037461446 scopus 로고    scopus 로고
    • Plasma spraying of functionally graded hydroxyapatite/Ti-6Al-4V coatings
    • Khor K.A., Gu Y.W., Quek C.H., Cheang P. Plasma spraying of functionally graded hydroxyapatite/Ti-6Al-4V coatings. Surf. Coat. Technol. 2003, 168:195-201.
    • (2003) Surf. Coat. Technol. , vol.168 , pp. 195-201
    • Khor, K.A.1    Gu, Y.W.2    Quek, C.H.3    Cheang, P.4
  • 10
    • 64249113833 scopus 로고    scopus 로고
    • Surface modification by electrical discharge machining: a review
    • Kumar S., Singh R., Singh T.P., Sethi B.L. Surface modification by electrical discharge machining: a review. J. Mater. Process. Technol. 2009, 209:3675-3687.
    • (2009) J. Mater. Process. Technol. , vol.209 , pp. 3675-3687
    • Kumar, S.1    Singh, R.2    Singh, T.P.3    Sethi, B.L.4
  • 11
    • 0742305201 scopus 로고    scopus 로고
    • Study of surface integrity using small area EDM process with a copper-tungsten electrode
    • Lee H.T., Hsu F.C., Tai T.Y. Study of surface integrity using small area EDM process with a copper-tungsten electrode. Mater. Sci. Eng. A 2004, 364:346-356.
    • (2004) Mater. Sci. Eng. A , vol.364 , pp. 346-356
    • Lee, H.T.1    Hsu, F.C.2    Tai, T.Y.3
  • 12
    • 0041953575 scopus 로고    scopus 로고
    • Wiley-VCH Verlag, C. Leyens, M. Peters (Eds.)
    • Titanium and Titanium Alloys 2003, Wiley-VCH Verlag. C. Leyens, M. Peters (Eds.).
    • (2003) Titanium and Titanium Alloys
  • 13
    • 1842560233 scopus 로고    scopus 로고
    • Applications of plasma coatings in artificial joints: an overview
    • Liang H., Shi B., Fairchild A., Cale T. Applications of plasma coatings in artificial joints: an overview. Vacuum 2004, 73:317-326.
    • (2004) Vacuum , vol.73 , pp. 317-326
    • Liang, H.1    Shi, B.2    Fairchild, A.3    Cale, T.4
  • 14
    • 12344298672 scopus 로고    scopus 로고
    • Surface modification of titanium, titanium alloys and related materials for biomedical applications
    • Liu X., Chu P.K., Ding C. Surface modification of titanium, titanium alloys and related materials for biomedical applications. Mater. Sci. Eng. R 2004, 47:49-121.
    • (2004) Mater. Sci. Eng. R , vol.47 , pp. 49-121
    • Liu, X.1    Chu, P.K.2    Ding, C.3
  • 15
    • 0032170254 scopus 로고    scopus 로고
    • Titanium alloys in total joint replacement-a materials science perspective
    • Long M., Rack H.J. Titanium alloys in total joint replacement-a materials science perspective. Biomaterials 1998, 19:1621-1639.
    • (1998) Biomaterials , vol.19 , pp. 1621-1639
    • Long, M.1    Rack, H.J.2
  • 17
    • 85163279081 scopus 로고    scopus 로고
    • Effects of supra- and sub-transus heat treatments on fatigue performance of Ti-6Al-4V. In: Ti-2007 Science and Technology. The Japan Institute of Metals
    • Mueller, J., Rack, H.J., Wagner, L., 2007. Effects of supra- and sub-transus heat treatments on fatigue performance of Ti-6Al-4V. In: Ti-2007 Science and Technology. The Japan Institute of Metals. pp. 383-386.
    • (2007) , pp. 383-386
    • Mueller, J.1    Rack, H.J.2    Wagner, L.3
  • 18
    • 0036494613 scopus 로고    scopus 로고
    • Influence of and microstructure on high cycle fatigue of Ti-6Al-4V: bimodal vs. lamellar structure
    • A
    • Nalla R.K., Boyce B.L., Campbell J.P., Peters J.O., Ritchie R.O. Influence of and microstructure on high cycle fatigue of Ti-6Al-4V: bimodal vs. lamellar structure. Metall. Mater. Trans. 2002, 33A:899-918.
    • (2002) Metall. Mater. Trans. , vol.33 , pp. 899-918
    • Nalla, R.K.1    Boyce, B.L.2    Campbell, J.P.3    Peters, J.O.4    Ritchie, R.O.5
  • 19
    • 33947267578 scopus 로고    scopus 로고
    • Fatigue characteristics of metallic biomaterials
    • Niinomi M. Fatigue characteristics of metallic biomaterials. Int. J. Fatigue 2007, 29:992-1000.
    • (2007) Int. J. Fatigue , vol.29 , pp. 992-1000
    • Niinomi, M.1
  • 20
    • 0034316784 scopus 로고    scopus 로고
    • Long crack growth behaviour of implant material Ti-5Al-2.5Fe in air and simulated body environment related to microstructure
    • Niinomi M., Saga A., Fukunaga K. Long crack growth behaviour of implant material Ti-5Al-2.5Fe in air and simulated body environment related to microstructure. Int. J. Fatigue 2000, 22:887-897.
    • (2000) Int. J. Fatigue , vol.22 , pp. 887-897
    • Niinomi, M.1    Saga, A.2    Fukunaga, K.3
  • 21
    • 76549097925 scopus 로고    scopus 로고
    • Effect of electrical-discharging on formation of nanoporous bicompatible layer on titanium
    • Peng P.W., Ou K.L., Lin H.C., Pan Y.N., Wang C.H. Effect of electrical-discharging on formation of nanoporous bicompatible layer on titanium. J. Alloys Compd. 2010, 492:625-630.
    • (2010) J. Alloys Compd. , vol.492 , pp. 625-630
    • Peng, P.W.1    Ou, K.L.2    Lin, H.C.3    Pan, Y.N.4    Wang, C.H.5
  • 22
    • 33746759403 scopus 로고    scopus 로고
    • Titanium alloys for biomedical applications
    • Rack H.J., Qazi J.I. Titanium alloys for biomedical applications. Mater. Sci. Eng. C 2006, 26:1269-1277.
    • (2006) Mater. Sci. Eng. C , vol.26 , pp. 1269-1277
    • Rack, H.J.1    Qazi, J.I.2
  • 24
    • 34547113311 scopus 로고    scopus 로고
    • Characteristics of hydroxyapatita coated titanium porous coatings on Ti-6Al-4V substrates by plasma sprayed method
    • Yang C.Y., Chen C.R., Chang E., Lee T.M. Characteristics of hydroxyapatita coated titanium porous coatings on Ti-6Al-4V substrates by plasma sprayed method. J. Biomed. Mater. Res. Part B 2007, 82:450-459.
    • (2007) J. Biomed. Mater. Res. Part B , vol.82 , pp. 450-459
    • Yang, C.Y.1    Chen, C.R.2    Chang, E.3    Lee, T.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.