메뉴 건너뛰기




Volumn 186, Issue 2-3, 2011, Pages 1154-1162

Poly(vinyl) chloride membrane copper-selective electrode based on 1-phenyl-2-(2-hydroxyphenylhydrazo)butane-1,3-dione

Author keywords

1 Phenyl 2 (2 hydroxyphenylhydrazo)butane 1,3 dione; Alloy analysis; Azoderivatives of diketones; Copper ion selective electrode; Potentiometry; PVC

Indexed keywords

1-PHENYL-2-(2-HYDROXYPHENYLHYDRAZO)BUTANE-1,3-DIONE; AZO-DERIVATIVES; COPPER ION-SELECTIVE ELECTRODE; POTENTIOMETRY; PVC;

EID: 79751529177     PISSN: 03043894     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhazmat.2010.11.119     Document Type: Article
Times cited : (75)

References (101)
  • 4
    • 0027010290 scopus 로고
    • Specific membrane transport of copper(II) ion by a cooperative carrier composed of 1,7-diaza-15-crown-5 and palmitic acid
    • Dadfarnia S., Shamsipur M. Specific membrane transport of copper(II) ion by a cooperative carrier composed of 1,7-diaza-15-crown-5 and palmitic acid. J. Membr. Sci. 1992, 75:61-68.
    • (1992) J. Membr. Sci. , vol.75 , pp. 61-68
    • Dadfarnia, S.1    Shamsipur, M.2
  • 6
    • 0002394176 scopus 로고
    • The development of polymer matrix membranes for ion-selective electrodes
    • Moody G.J., Saad B.B., Thomas J.D.R. The development of polymer matrix membranes for ion-selective electrodes. Sel. Electrode Rev. 1988, 10:71-106.
    • (1988) Sel. Electrode Rev. , vol.10 , pp. 71-106
    • Moody, G.J.1    Saad, B.B.2    Thomas, J.D.R.3
  • 8
    • 0032812357 scopus 로고    scopus 로고
    • The use of 1-[pyridyl-(2)-azo]-naphthol-(2) in the presence of TX 100 and N,N′-diphenylbenzamidine for the spectrophotometric determination of copper in real samples
    • Thakur M., Deb M.K. The use of 1-[pyridyl-(2)-azo]-naphthol-(2) in the presence of TX 100 and N,N′-diphenylbenzamidine for the spectrophotometric determination of copper in real samples. Talanta 1999, 49:561-569.
    • (1999) Talanta , vol.49 , pp. 561-569
    • Thakur, M.1    Deb, M.K.2
  • 9
    • 0033306745 scopus 로고    scopus 로고
    • Spectrophotometric determination of copper in metallic alloy using a bidithiolene: a comparative study
    • Barreto S.R.G., Nozaki J., Barreto W.J. Spectrophotometric determination of copper in metallic alloy using a bidithiolene: a comparative study. Microchem. J. 1999, 62:223-228.
    • (1999) Microchem. J. , vol.62 , pp. 223-228
    • Barreto, S.R.G.1    Nozaki, J.2    Barreto, W.J.3
  • 10
    • 0030595016 scopus 로고    scopus 로고
    • Spectrophotometric determination of copper after extraction of its chelate with bis(acetylacetone)ethylenediimine
    • Chimpalee N., Chimpalee D., Lohwithee S., Nakwatchara L., Burns D.T. Spectrophotometric determination of copper after extraction of its chelate with bis(acetylacetone)ethylenediimine. Anal. Chim. Acta 1996, 329:315-318.
    • (1996) Anal. Chim. Acta , vol.329 , pp. 315-318
    • Chimpalee, N.1    Chimpalee, D.2    Lohwithee, S.3    Nakwatchara, L.4    Burns, D.T.5
  • 11
    • 0042826033 scopus 로고    scopus 로고
    • A new spectrophotometric reagent for copper: 3,3′-(1,3-propanediyldiimine)bis-[3-methyl-2-butanone]dioxime
    • Karabocek S., Nohut S., Dalman O., Guner S. A new spectrophotometric reagent for copper: 3,3′-(1,3-propanediyldiimine)bis-[3-methyl-2-butanone]dioxime. Anal. Chim. Acta 2000, 408:163-168.
    • (2000) Anal. Chim. Acta , vol.408 , pp. 163-168
    • Karabocek, S.1    Nohut, S.2    Dalman, O.3    Guner, S.4
  • 12
    • 0033538887 scopus 로고    scopus 로고
    • A spectrophotometric determination of Cu(II) with sequential injection analysis
    • Van Staden J.F., Botha A. A spectrophotometric determination of Cu(II) with sequential injection analysis. Talanta 1999, 49:1099-1108.
    • (1999) Talanta , vol.49 , pp. 1099-1108
    • Van Staden, J.F.1    Botha, A.2
  • 13
    • 17144386630 scopus 로고    scopus 로고
    • N-Aryl-3-amino-propionic acids as selective reagents for the determination of copper in metallurgical products
    • Neudachina L.K., O{cyrillic}shintseva Ye{cyrillic}.V., Skorik Y.A{cyrillic}., Vshivkova{cyrillic} A{cyrillic}.A{cyrillic}. N-Aryl-3-amino-propionic acids as selective reagents for the determination of copper in metallurgical products. J. Anal. Chem. 2005, 60:240-246.
    • (2005) J. Anal. Chem. , vol.60 , pp. 240-246
    • Neudachina, L.K.1    Oshintseva, Ye.V.2    Skorik, Y.A.3    Vshivkova, A.A.4
  • 14
    • 0031005107 scopus 로고    scopus 로고
    • Application of sequential injection analysis to anodic stripping voltammetry
    • Ivaska A., Kubiak W.W. Application of sequential injection analysis to anodic stripping voltammetry. Talanta 1997, 44:713-723.
    • (1997) Talanta , vol.44 , pp. 713-723
    • Ivaska, A.1    Kubiak, W.W.2
  • 15
    • 47649117031 scopus 로고    scopus 로고
    • Solid phase extraction of lead (II), copper (II), cadmium (II) and nickel (II) using gallic acid-modified silica gel prior to determination by flame atomic absorption spectrometry
    • Mashhadizadeh M.H., Pesteh M., Talakesh M., Sheikhshoaie I., Ardakani M.M., Karimi M.A. Solid phase extraction of lead (II), copper (II), cadmium (II) and nickel (II) using gallic acid-modified silica gel prior to determination by flame atomic absorption spectrometry. Spectrochim. Acta B 2008, 63:885-888.
    • (2008) Spectrochim. Acta B , vol.63 , pp. 885-888
    • Mashhadizadeh, M.H.1    Pesteh, M.2    Talakesh, M.3    Sheikhshoaie, I.4    Ardakani, M.M.5    Karimi, M.A.6
  • 16
    • 21344459079 scopus 로고    scopus 로고
    • Synthesis and application of a functionalized resin for flow injection/F AAS copper determination in waters
    • Cassella R.J., Magalhaes O.I.B., Couto M.T., Lima E.L.S., Neves M.A.F.S., Coutinho F.M.B. Synthesis and application of a functionalized resin for flow injection/F AAS copper determination in waters. Talanta 2005, 67:121-128.
    • (2005) Talanta , vol.67 , pp. 121-128
    • Cassella, R.J.1    Magalhaes, O.I.B.2    Couto, M.T.3    Lima, E.L.S.4    Neves, M.A.F.S.5    Coutinho, F.M.B.6
  • 17
    • 0034473435 scopus 로고    scopus 로고
    • Flame AAS determination of copper in urine using a flow injection on-line preconcentration system based on a polyamine chelating ion exchange column
    • Almeida A.A., Jun X., Lima J.L.F.C. Flame AAS determination of copper in urine using a flow injection on-line preconcentration system based on a polyamine chelating ion exchange column. Atom. Spectrosc. 2000, 21:187-193.
    • (2000) Atom. Spectrosc. , vol.21 , pp. 187-193
    • Almeida, A.A.1    Jun, X.2    Lima, J.L.F.C.3
  • 18
    • 0037045274 scopus 로고    scopus 로고
    • Determination of copper, iron, lead and nickel in gasoline by electrothermal atomic absorption spectrometry using three component solutions
    • Campos R.C., Santos H.R., Grinberg P. Determination of copper, iron, lead and nickel in gasoline by electrothermal atomic absorption spectrometry using three component solutions. Spectrochim. Acta B 2002, 57:15-28.
    • (2002) Spectrochim. Acta B , vol.57 , pp. 15-28
    • Campos, R.C.1    Santos, H.R.2    Grinberg, P.3
  • 19
    • 0037010547 scopus 로고    scopus 로고
    • Application of factorial designs and Doehlert matrix in optimization of experimental variables associated with the preconcentration and determination of vanadium and copper in seawater by inductively coupled plasma optical emission spectrometry
    • Ferreira S.L.C., Queiroz A.S., Fernandes M.S., dos Santos H.C. Application of factorial designs and Doehlert matrix in optimization of experimental variables associated with the preconcentration and determination of vanadium and copper in seawater by inductively coupled plasma optical emission spectrometry. Spectrochim. Acta B 2002, 57:1939-1950.
    • (2002) Spectrochim. Acta B , vol.57 , pp. 1939-1950
    • Ferreira, S.L.C.1    Queiroz, A.S.2    Fernandes, M.S.3    dos Santos, H.C.4
  • 23
    • 0032563672 scopus 로고    scopus 로고
    • Simultaneous determination of trace amounts of nickel, copper and mercury by liquid chromatography coupled with flow-injection online derivatization and preconcentration
    • Ali A., Shen H., Yin X. Simultaneous determination of trace amounts of nickel, copper and mercury by liquid chromatography coupled with flow-injection online derivatization and preconcentration. Anal. Chim. Acta 1998, 369:215-223.
    • (1998) Anal. Chim. Acta , vol.369 , pp. 215-223
    • Ali, A.1    Shen, H.2    Yin, X.3
  • 25
    • 33947331392 scopus 로고    scopus 로고
    • Voltammetric determination of Cu(II) in natural waters and human hair at a meso-2,3-dimercaptosuccinic acid self-assembled gold electrode
    • Mohadesi A., Taher M.A. Voltammetric determination of Cu(II) in natural waters and human hair at a meso-2,3-dimercaptosuccinic acid self-assembled gold electrode. Talanta 2007, 72:95-100.
    • (2007) Talanta , vol.72 , pp. 95-100
    • Mohadesi, A.1    Taher, M.A.2
  • 27
    • 0032099044 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    • Buhlmann P., Pretsch E., Bakker E. Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors. Chem. Rev. 1998, 98:1593-1687.
    • (1998) Chem. Rev. , vol.98 , pp. 1593-1687
    • Buhlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 28
    • 0024106504 scopus 로고
    • Copper(II)-selective electrode using thiuram disulfide neutral carriers
    • Kamata S., Bhale A., Fukunaga Y., Murata H. Copper(II)-selective electrode using thiuram disulfide neutral carriers. Anal. Chem. 1988, 60:2464-2467.
    • (1988) Anal. Chem. , vol.60 , pp. 2464-2467
    • Kamata, S.1    Bhale, A.2    Fukunaga, Y.3    Murata, H.4
  • 29
    • 0023737682 scopus 로고
    • Copper(II)-selective electrodes based on macrocyclic polythiaethers
    • Kamata S., Yamasaki Y., Higo M., Bhalen A., Fukanaga Y. Copper(II)-selective electrodes based on macrocyclic polythiaethers. Analyst 1988, 113:45-47.
    • (1988) Analyst , vol.113 , pp. 45-47
    • Kamata, S.1    Yamasaki, Y.2    Higo, M.3    Bhalen, A.4    Fukanaga, Y.5
  • 30
    • 0000560649 scopus 로고
    • Transition metal ion-selective membrane electrodes based on complexing compounds with heteroatoms part 11. Complexing compounds containing sulphur atoms
    • Brzozka Z. Transition metal ion-selective membrane electrodes based on complexing compounds with heteroatoms part 11. Complexing compounds containing sulphur atoms. Analyst 1988, 113:1803-1805.
    • (1988) Analyst , vol.113 , pp. 1803-1805
    • Brzozka, Z.1
  • 31
    • 37049079895 scopus 로고
    • Copper(II)-selective membrane electrodes based on o-xylylene bis(dithiocarbamates) as neutral carriers
    • Kamata S., Murata H., Kubo Y., Bhale A. Copper(II)-selective membrane electrodes based on o-xylylene bis(dithiocarbamates) as neutral carriers. Analyst 1989, 114:1029-1031.
    • (1989) Analyst , vol.114 , pp. 1029-1031
    • Kamata, S.1    Murata, H.2    Kubo, Y.3    Bhale, A.4
  • 32
    • 0000784569 scopus 로고
    • Transduction of selective recognition of heavy metal ions by chemically modified field effect transistors (CHEMFETs)
    • Cobber P.L.H.M., Gherkin R.J.M., Boomer J.B., Barged P., Vroom W., Reinhoudt D.N. Transduction of selective recognition of heavy metal ions by chemically modified field effect transistors (CHEMFETs). J. Am. Chem. Soc. 1992, 114:10573-10582.
    • (1992) J. Am. Chem. Soc. , vol.114 , pp. 10573-10582
    • Cobber, P.L.H.M.1    Gherkin, R.J.M.2    Boomer, J.B.3    Barged, P.4    Vroom, W.5    Reinhoudt, D.N.6
  • 33
    • 0001189032 scopus 로고    scopus 로고
    • Copper(II)-selective membrane electrode based on a recently synthesized naphthol-derivative Schiff's base
    • Alizadeh N., Ershad S., Naeimi H., Sharghi H., Shamsipur M. Copper(II)-selective membrane electrode based on a recently synthesized naphthol-derivative Schiff's base. Fresenius J. Anal. Chem. 1999, 365:511-515.
    • (1999) Fresenius J. Anal. Chem. , vol.365 , pp. 511-515
    • Alizadeh, N.1    Ershad, S.2    Naeimi, H.3    Sharghi, H.4    Shamsipur, M.5
  • 34
    • 0344629238 scopus 로고    scopus 로고
    • Copper potentiometric sensors based on copper complexes containing thiohydrazone and thiosemicarbazone ligands
    • Gismera M.J., Mendiola M.A., Procopio J.R., Sevilla M.T. Copper potentiometric sensors based on copper complexes containing thiohydrazone and thiosemicarbazone ligands. Anal. Chim. Acta 1999, 385:143-149.
    • (1999) Anal. Chim. Acta , vol.385 , pp. 143-149
    • Gismera, M.J.1    Mendiola, M.A.2    Procopio, J.R.3    Sevilla, M.T.4
  • 35
    • 0001626956 scopus 로고    scopus 로고
    • Copper(II)-selective membrane electrode based on a recently synthesized macrocyclic diamide
    • Shamsipur M., Rouhani S., Ganjali M.R., Eshghi H., Sharghi H. Copper(II)-selective membrane electrode based on a recently synthesized macrocyclic diamide. Microchem. J. 1999, 63:202-210.
    • (1999) Microchem. J. , vol.63 , pp. 202-210
    • Shamsipur, M.1    Rouhani, S.2    Ganjali, M.R.3    Eshghi, H.4    Sharghi, H.5
  • 36
    • 0035944967 scopus 로고    scopus 로고
    • Copper(II)-selective membrane electrodes based on some recently synthesized mixed aza-thioether crowns containing a 1,10-phenanthroline sub-unit
    • Shamsipur M., Javanbakht M., Mousavi M.F., Ganjali M.R., Lippolis V., Garau A., Tei L. Copper(II)-selective membrane electrodes based on some recently synthesized mixed aza-thioether crowns containing a 1,10-phenanthroline sub-unit. Talanta 2001, 55:1047-1054.
    • (2001) Talanta , vol.55 , pp. 1047-1054
    • Shamsipur, M.1    Javanbakht, M.2    Mousavi, M.F.3    Ganjali, M.R.4    Lippolis, V.5    Garau, A.6    Tei, L.7
  • 37
    • 3042688108 scopus 로고    scopus 로고
    • Characteristics of lariat crown ether-copper(II) ion-selective electrodes
    • Su C.C., Ueng C.H., Liu L.K. Characteristics of lariat crown ether-copper(II) ion-selective electrodes. J. Chin. Chem. Soc. 2001, 48:733-738.
    • (2001) J. Chin. Chem. Soc. , vol.48 , pp. 733-738
    • Su, C.C.1    Ueng, C.H.2    Liu, L.K.3
  • 40
    • 0035972879 scopus 로고    scopus 로고
    • Copper(II)-selective electrode using 2,2′-dithiodianiline as neutral carrier
    • Gholivand M.B., Nozari N. Copper(II)-selective electrode using 2,2′-dithiodianiline as neutral carrier. Talanta 2001, 54:597-602.
    • (2001) Talanta , vol.54 , pp. 597-602
    • Gholivand, M.B.1    Nozari, N.2
  • 41
    • 0035958328 scopus 로고    scopus 로고
    • Effect of concentration of ion exchanger, plasticizer and molecular weight of cyanocopolymers on selectivity and sensitivity of Cu(II) ion selective electrodes
    • Gupta K.C., D'Arc M.J. Effect of concentration of ion exchanger, plasticizer and molecular weight of cyanocopolymers on selectivity and sensitivity of Cu(II) ion selective electrodes. Anal. Chim. Acta 2001, 437:199-216.
    • (2001) Anal. Chim. Acta , vol.437 , pp. 199-216
    • Gupta, K.C.1    D'Arc, M.J.2
  • 42
    • 0037170688 scopus 로고    scopus 로고
    • Copper(II)-selective electrode based on dithioacetal
    • Abbaspur A., Kamyabi M.A. Copper(II)-selective electrode based on dithioacetal. Anal. Chim. Acta 2002, 455:225-231.
    • (2002) Anal. Chim. Acta , vol.455 , pp. 225-231
    • Abbaspur, A.1    Kamyabi, M.A.2
  • 43
    • 0037145577 scopus 로고    scopus 로고
    • Novel copper(II)-selective sensor based on a new hexadentates Schiff's base
    • Ganjali M.R., Emami M., Salavati-Niasari M. Novel copper(II)-selective sensor based on a new hexadentates Schiff's base. Bull. Korean Chem. Soc. 2002, 23:1394-1398.
    • (2002) Bull. Korean Chem. Soc. , vol.23 , pp. 1394-1398
    • Ganjali, M.R.1    Emami, M.2    Salavati-Niasari, M.3
  • 44
    • 0036670287 scopus 로고    scopus 로고
    • A 9,10-anthraquinone derivative having two propenyl arms as a neutral ionophore for highly selective and sensitive membrane sensor for copper(II) ion
    • Shamsipur M., Avanes A., Javanbakht M., Ganjali M.R., Sharghi H. A 9,10-anthraquinone derivative having two propenyl arms as a neutral ionophore for highly selective and sensitive membrane sensor for copper(II) ion. Anal. Sci. 2002, 18:875-879.
    • (2002) Anal. Sci. , vol.18 , pp. 875-879
    • Shamsipur, M.1    Avanes, A.2    Javanbakht, M.3    Ganjali, M.R.4    Sharghi, H.5
  • 45
    • 0037144295 scopus 로고    scopus 로고
    • Highly selective Cu(II) PVC membrane electrode based on 3,6,9,14-tetrathiabicyclo[9. 2. 1]tetradeca-11,13-diene as a suitable neutral ionophore
    • Mashhadizadeh M.H., Mostafavi A., Razavi R., Shamsipur M. Highly selective Cu(II) PVC membrane electrode based on 3,6,9,14-tetrathiabicyclo[9. 2. 1]tetradeca-11,13-diene as a suitable neutral ionophore. Sens. Actuators B 2002, 86:222-228.
    • (2002) Sens. Actuators B , vol.86 , pp. 222-228
    • Mashhadizadeh, M.H.1    Mostafavi, A.2    Razavi, R.3    Shamsipur, M.4
  • 46
    • 0036208490 scopus 로고    scopus 로고
    • Coated-wire copper(II)-selective electrode based on phenylglyoxal-α-monoxime ionophore
    • Firooz A.R., Mazloum M., Safari J., Amini M.K. Coated-wire copper(II)-selective electrode based on phenylglyoxal-α-monoxime ionophore. Anal. Bioanal. Chem. 2002, 372:718-722.
    • (2002) Anal. Bioanal. Chem. , vol.372 , pp. 718-722
    • Firooz, A.R.1    Mazloum, M.2    Safari, J.3    Amini, M.K.4
  • 47
    • 0141761152 scopus 로고    scopus 로고
    • Copper(II)-selective membrane electrode based on hydrotris(3-isopropylpyrazolyl)methane in a poly(vinyl chloride) matrix
    • Yoshimoto S., Mukai H., Kitano T., Sohrin Y. Copper(II)-selective membrane electrode based on hydrotris(3-isopropylpyrazolyl)methane in a poly(vinyl chloride) matrix. Anal. Chim. Acta 2003, 494:207-213.
    • (2003) Anal. Chim. Acta , vol.494 , pp. 207-213
    • Yoshimoto, S.1    Mukai, H.2    Kitano, T.3    Sohrin, Y.4
  • 48
    • 0037327917 scopus 로고    scopus 로고
    • Novel PVC-based copper(II) membrane sensor based on 2-(1′-(4′-(1′-hydroxy-2″-naphthyl) methyleneamino)butyl iminomethyl)-1-naphthol
    • Ganjali M.R., Golmohammadi M., Yousefi M., Norouzi P., Salavati-Niasari M., Javanbakht M. Novel PVC-based copper(II) membrane sensor based on 2-(1′-(4′-(1′-hydroxy-2″-naphthyl) methyleneamino)butyl iminomethyl)-1-naphthol. Anal. Sci. 2003, 19:223-227.
    • (2003) Anal. Sci. , vol.19 , pp. 223-227
    • Ganjali, M.R.1    Golmohammadi, M.2    Yousefi, M.3    Norouzi, P.4    Salavati-Niasari, M.5    Javanbakht, M.6
  • 50
    • 0041666353 scopus 로고    scopus 로고
    • Highly selective copper membrane electrode using C-p-nitrophenyl-N-phenylnitrone
    • Ardakani M.M., Safaei-Ghomi J., Mehdipoor M. Highly selective copper membrane electrode using C-p-nitrophenyl-N-phenylnitrone. New J. Chem. 2003, 27:1140-1143.
    • (2003) New J. Chem. , vol.27 , pp. 1140-1143
    • Ardakani, M.M.1    Safaei-Ghomi, J.2    Mehdipoor, M.3
  • 51
    • 4143084077 scopus 로고    scopus 로고
    • Copper(II) selective electrochemical sensor based on Schiff Base complexes
    • Singh L.P., Bhatnagar J.M. Copper(II) selective electrochemical sensor based on Schiff Base complexes. Talanta 2004, 64:313-319.
    • (2004) Talanta , vol.64 , pp. 313-319
    • Singh, L.P.1    Bhatnagar, J.M.2
  • 52
    • 7044264395 scopus 로고    scopus 로고
    • Highly selective coated-wire copper-selective electrode based on N, N′-ethylene bis(p-tert-butyl salicyl aldiminato)
    • Ardakani M.M., Salavati-Niasari M., Pourhakkak P. Highly selective coated-wire copper-selective electrode based on N, N′-ethylene bis(p-tert-butyl salicyl aldiminato). Bull. Electrochem. 2004, 20:213-217.
    • (2004) Bull. Electrochem. , vol.20 , pp. 213-217
    • Ardakani, M.M.1    Salavati-Niasari, M.2    Pourhakkak, P.3
  • 53
    • 13244296388 scopus 로고    scopus 로고
    • A copper ion-selective electrode with high selectivity prepared by sol-gel and coated wire techniques
    • Ardakani M.M., Salavati-Niasari M., Kashani M.K., Ghoreishi S.M. A copper ion-selective electrode with high selectivity prepared by sol-gel and coated wire techniques. Anal. Bioanal. Chem. 2004, 378:1659-1665.
    • (2004) Anal. Bioanal. Chem. , vol.378 , pp. 1659-1665
    • Ardakani, M.M.1    Salavati-Niasari, M.2    Kashani, M.K.3    Ghoreishi, S.M.4
  • 54
    • 10644291880 scopus 로고    scopus 로고
    • Copper-selective PVC membrane electrodes based on salens as carriers
    • Fakhari A.R., Raji T.A., Naeimi H. Copper-selective PVC membrane electrodes based on salens as carriers. Sens. Actuators B 2005, 104:317-323.
    • (2005) Sens. Actuators B , vol.104 , pp. 317-323
    • Fakhari, A.R.1    Raji, T.A.2    Naeimi, H.3
  • 55
    • 29744435953 scopus 로고    scopus 로고
    • Highly selective and sensitive copper(II) membrane sensors based on 6-methyl-4-(1-phenylmethylidene) amino-3-thioxo-1,2,4-triazin-5-one as a new neutral ionophore
    • Zamani H.A., Rajadzadeh G., Ganjali M.R., Mola-Khatami S. Highly selective and sensitive copper(II) membrane sensors based on 6-methyl-4-(1-phenylmethylidene) amino-3-thioxo-1,2,4-triazin-5-one as a new neutral ionophore. Electroanalysis 2005, 17:2260-2265.
    • (2005) Electroanalysis , vol.17 , pp. 2260-2265
    • Zamani, H.A.1    Rajadzadeh, G.2    Ganjali, M.R.3    Mola-Khatami, S.4
  • 57
    • 30744467160 scopus 로고    scopus 로고
    • Synthesis of 4-amino-6-methyl-1,2,4-triazin-5-one-3-thione and its application in construction of a highly copper(II) ion-selective electrochemical sensor
    • Zamani H.A., Rajabzadeh G., Firouz A., Ariaii-Rad A.A. Synthesis of 4-amino-6-methyl-1,2,4-triazin-5-one-3-thione and its application in construction of a highly copper(II) ion-selective electrochemical sensor. J. Brazil. Chem. Soc. 2005, 16:1061-1067.
    • (2005) J. Brazil. Chem. Soc. , vol.16 , pp. 1061-1067
    • Zamani, H.A.1    Rajabzadeh, G.2    Firouz, A.3    Ariaii-Rad, A.A.4
  • 58
    • 22744456393 scopus 로고    scopus 로고
    • Development of a new copper(II) ion-selective poly(vinyl chloride) membrane electrode based on 2-mercaptobenzoxazole
    • Akhond M., Ghaedi M., Tashkhourian J. Development of a new copper(II) ion-selective poly(vinyl chloride) membrane electrode based on 2-mercaptobenzoxazole. Bull. Korean Chem. Soc. 2005, 26:882-886.
    • (2005) Bull. Korean Chem. Soc. , vol.26 , pp. 882-886
    • Akhond, M.1    Ghaedi, M.2    Tashkhourian, J.3
  • 59
    • 33745959605 scopus 로고    scopus 로고
    • Copper selective electrode based on 1,8-bis(2-hydroxynaphthaldiminato)3,6-dioxaoctane
    • Ardakani M.M., Mirhoseini S.H., Salavati-Niasari M. Copper selective electrode based on 1,8-bis(2-hydroxynaphthaldiminato)3,6-dioxaoctane. Acta Chim. Slov. 2006, 53:197-203.
    • (2006) Acta Chim. Slov. , vol.53 , pp. 197-203
    • Ardakani, M.M.1    Mirhoseini, S.H.2    Salavati-Niasari, M.3
  • 60
    • 33749026060 scopus 로고    scopus 로고
    • Determination of copper in black, red pepper and the waste water samples by a highly selective sensitive Cu(II) microelectrode based on a new hexadentates Schiff's base
    • Norouzi P., Ganjali M.R., Faridbod F., Salavati-Niasari M. Determination of copper in black, red pepper and the waste water samples by a highly selective sensitive Cu(II) microelectrode based on a new hexadentates Schiff's base. Bull. Korean Chem. Soc. 2006, 27:1439-1444.
    • (2006) Bull. Korean Chem. Soc. , vol.27 , pp. 1439-1444
    • Norouzi, P.1    Ganjali, M.R.2    Faridbod, F.3    Salavati-Niasari, M.4
  • 61
    • 33645354833 scopus 로고    scopus 로고
    • Copper(II) ion selective liquid membrane electrode based on new Schiff base carrier
    • Sadeghi S., Vardini M.T., Naeimi H. Copper(II) ion selective liquid membrane electrode based on new Schiff base carrier. Annali Di Chim. 2006, 96:65-74.
    • (2006) Annali Di Chim. , vol.96 , pp. 65-74
    • Sadeghi, S.1    Vardini, M.T.2    Naeimi, H.3
  • 62
    • 34548641084 scopus 로고    scopus 로고
    • Novel copper(II)-selective membrane electrode based on a new synthesized Schiff base
    • Akhond M., Najafi M.B., Sharghi H., Tashkhourian J., Naiemi H. Novel copper(II)-selective membrane electrode based on a new synthesized Schiff base. J. Chin. Chem. Soc. 2007, 54:331-337.
    • (2007) J. Chin. Chem. Soc. , vol.54 , pp. 331-337
    • Akhond, M.1    Najafi, M.B.2    Sharghi, H.3    Tashkhourian, J.4    Naiemi, H.5
  • 63
    • 44949171643 scopus 로고    scopus 로고
    • A copper(II)-selective PVC membrane electrode based on a macrocyclic ligand,1,2,5,6,8,11-hexaazacyclododeca-7,12-dione-2,4,8,10-tetraene
    • Chandra S., Singh C.K., Agarwal H., Agarwal R.K. A copper(II)-selective PVC membrane electrode based on a macrocyclic ligand,1,2,5,6,8,11-hexaazacyclododeca-7,12-dione-2,4,8,10-tetraene. Anal. Sci. 2007, 23:683-687.
    • (2007) Anal. Sci. , vol.23 , pp. 683-687
    • Chandra, S.1    Singh, C.K.2    Agarwal, H.3    Agarwal, R.K.4
  • 64
    • 43049177902 scopus 로고    scopus 로고
    • Copper(II) ion selective electrode based on a newly synthesized Schiff-base chelate
    • Jain A.K., Singh R.K., Jain S., Raisoni J. Copper(II) ion selective electrode based on a newly synthesized Schiff-base chelate. Trans. Met. Chem. 2008, 33:243-249.
    • (2008) Trans. Met. Chem. , vol.33 , pp. 243-249
    • Jain, A.K.1    Singh, R.K.2    Jain, S.3    Raisoni, J.4
  • 65
    • 15444379562 scopus 로고    scopus 로고
    • Azoderivative of 2-thenoyltrifluoroacetone as a reagent for the photometric determination of copper(II)
    • Aliyeva R.A., Chyragov F.M., Mahmudov K.T. Azoderivative of 2-thenoyltrifluoroacetone as a reagent for the photometric determination of copper(II). J. Anal. Chem. 2005, 60:137-141.
    • (2005) J. Anal. Chem. , vol.60 , pp. 137-141
    • Aliyeva, R.A.1    Chyragov, F.M.2    Mahmudov, K.T.3
  • 67
    • 33745661413 scopus 로고    scopus 로고
    • Study of interaction in the system copper(II)-3-(2-hydroxy-3-sulfo-5-nitrophenylazo)pentadion-2,4 cationic surface-active substances
    • Gadjieva S.R., Mahmudov K.T., Chyragov F.M. Study of interaction in the system copper(II)-3-(2-hydroxy-3-sulfo-5-nitrophenylazo)pentadion-2,4 cationic surface-active substances. J. Anal. Chem. 2006, 61:634-637.
    • (2006) J. Anal. Chem. , vol.61 , pp. 634-637
    • Gadjieva, S.R.1    Mahmudov, K.T.2    Chyragov, F.M.3
  • 68
    • 35649010041 scopus 로고    scopus 로고
    • Complexation of copper(II) with azoderivatives of benzoylacetone
    • Gadjieva S.R., Chyragov F.M., Mahmudov K.T. Complexation of copper(II) with azoderivatives of benzoylacetone. J. Anal. Chem. 2007, 62:1028-1031.
    • (2007) J. Anal. Chem. , vol.62 , pp. 1028-1031
    • Gadjieva, S.R.1    Chyragov, F.M.2    Mahmudov, K.T.3
  • 69
    • 43049129211 scopus 로고    scopus 로고
    • Photometric determination of copper(II) in nickel alloys using azoderivatives of ethylacetoacetate
    • Mahmudov K.T., Aliyeva R.A., Gadjieva S.R., Chyragov F.M. Photometric determination of copper(II) in nickel alloys using azoderivatives of ethylacetoacetate. J. Anal. Chem. 2008, 63:435-438.
    • (2008) J. Anal. Chem. , vol.63 , pp. 435-438
    • Mahmudov, K.T.1    Aliyeva, R.A.2    Gadjieva, S.R.3    Chyragov, F.M.4
  • 70
    • 78650193245 scopus 로고    scopus 로고
    • Ion pairs of 5,5-dimethyl-2-(2-hydroxy-3,5-disulfophenylhydrazo)cyclohexane-1,3-dione with cationic surface-active substances as analytical reagent for determination of copper(II)
    • Mahmudov K.T., Maharramov A.M., Aliyeva R.A., Aliyev I.A., Kopylovich M.N., Pombeiro A.J.L. Ion pairs of 5,5-dimethyl-2-(2-hydroxy-3,5-disulfophenylhydrazo)cyclohexane-1,3-dione with cationic surface-active substances as analytical reagent for determination of copper(II). Anal. Lett. 2010, 43:2923-2938.
    • (2010) Anal. Lett. , vol.43 , pp. 2923-2938
    • Mahmudov, K.T.1    Maharramov, A.M.2    Aliyeva, R.A.3    Aliyev, I.A.4    Kopylovich, M.N.5    Pombeiro, A.J.L.6
  • 71
    • 74149085794 scopus 로고    scopus 로고
    • New copper(II) dimer with 3-(2-hydroxy-4-nitrophenylhydrazo)pentane-2,4-dione and its catalytic activity in cyclohexane and benzyl alcohol oxidations
    • Mahmudov K.T., Kopylovich M.N., Guedes da Silva M.F.C., Figiel P.J., Karabach Y.Y., Pombeiro A.J.L. New copper(II) dimer with 3-(2-hydroxy-4-nitrophenylhydrazo)pentane-2,4-dione and its catalytic activity in cyclohexane and benzyl alcohol oxidations. J. Mol. Catal. A Chem. 2010, 318:44-50.
    • (2010) J. Mol. Catal. A Chem. , vol.318 , pp. 44-50
    • Mahmudov, K.T.1    Kopylovich, M.N.2    Guedes da Silva, M.F.C.3    Figiel, P.J.4    Karabach, Y.Y.5    Pombeiro, A.J.L.6
  • 73
    • 9344221615 scopus 로고    scopus 로고
    • Dissociation constants of 2-tenyl-trifluoroacetone azoderivative and stability constants of its complexes
    • Aliyeva R.A., Chyragov F.M., Mahmudov K.T. Dissociation constants of 2-tenyl-trifluoroacetone azoderivative and stability constants of its complexes. Russ. J. Inorg. Chem. 2004, 49:1458-1460.
    • (2004) Russ. J. Inorg. Chem. , vol.49 , pp. 1458-1460
    • Aliyeva, R.A.1    Chyragov, F.M.2    Mahmudov, K.T.3
  • 74
    • 65449179193 scopus 로고    scopus 로고
    • Quantum-chemical calculations of the tautomeric forms of azoderivatives of acetylacetone and determination of the stability constants of their complexes with rare-earth metals
    • Aliyeva R.A., Pashaev F.H., Gasanov A.G., Mahmudov K.T. Quantum-chemical calculations of the tautomeric forms of azoderivatives of acetylacetone and determination of the stability constants of their complexes with rare-earth metals. Russ. J. Coord. Chem. 2009, 35:241-246.
    • (2009) Russ. J. Coord. Chem. , vol.35 , pp. 241-246
    • Aliyeva, R.A.1    Pashaev, F.H.2    Gasanov, A.G.3    Mahmudov, K.T.4
  • 75
    • 9344248981 scopus 로고    scopus 로고
    • Determination of dissociation constants of some azoderivatives of acetylacetone and stability constants of their complexes
    • Gadjieva S.R., Mahmudov K.T. Determination of dissociation constants of some azoderivatives of acetylacetone and stability constants of their complexes. Russ. J. Inorg. Chem. 2004, 49:1291-1294.
    • (2004) Russ. J. Inorg. Chem. , vol.49 , pp. 1291-1294
    • Gadjieva, S.R.1    Mahmudov, K.T.2
  • 76
    • 9344250513 scopus 로고    scopus 로고
    • Thermodynamic characterization of metal complexation with 3-(5-sulfonaphthylazo) pentanedione-2,4 in aqueous solution
    • Aliyeva R.A., Chyragov F.M., Babanly I.M., Mahmudov K.T., Babanly M.B. Thermodynamic characterization of metal complexation with 3-(5-sulfonaphthylazo) pentanedione-2,4 in aqueous solution. Russ. J. Inorg. Chem. 2004, 49:1461-1464.
    • (2004) Russ. J. Inorg. Chem. , vol.49 , pp. 1461-1464
    • Aliyeva, R.A.1    Chyragov, F.M.2    Babanly, I.M.3    Mahmudov, K.T.4    Babanly, M.B.5
  • 77
    • 14844364012 scopus 로고    scopus 로고
    • Thermodynamic characterization of complexation of some metals with 3-(4-sulfophenylazo)pentanedione-2,4 in aqueous solution
    • Aliyeva R.A., Chyragov F.M., Mahmudov K.T., Babanly M.B. Thermodynamic characterization of complexation of some metals with 3-(4-sulfophenylazo)pentanedione-2,4 in aqueous solution. Russ. J. Inorg. Chem. 2005, 50:131-134.
    • (2005) Russ. J. Inorg. Chem. , vol.50 , pp. 131-134
    • Aliyeva, R.A.1    Chyragov, F.M.2    Mahmudov, K.T.3    Babanly, M.B.4
  • 78
    • 33645740874 scopus 로고    scopus 로고
    • Quantum-chemical calculations of the tautomeric forms of 3-phenylazopentane-2,4-dione and the thermodynamic parameters of complexation between its isomers and some metals in aqueous ethanol
    • Gadjieva S.R., Mursalov T.M., Mahmudov K.T., Chyragov F.M. Quantum-chemical calculations of the tautomeric forms of 3-phenylazopentane-2,4-dione and the thermodynamic parameters of complexation between its isomers and some metals in aqueous ethanol. Russ. J. Coord. Chem. 2006, 32:304-308.
    • (2006) Russ. J. Coord. Chem. , vol.32 , pp. 304-308
    • Gadjieva, S.R.1    Mursalov, T.M.2    Mahmudov, K.T.3    Chyragov, F.M.4
  • 79
    • 8744250308 scopus 로고    scopus 로고
    • Dissociation constants for sulfoarylazo derivatives of acetylacetone and stability constants for their complexes
    • Aliyeva R.A., Chyragov F.M., Mahmudov K.T. Dissociation constants for sulfoarylazo derivatives of acetylacetone and stability constants for their complexes. Russ. J. Inorg. Chem. 2004, 49:1111-1113.
    • (2004) Russ. J. Inorg. Chem. , vol.49 , pp. 1111-1113
    • Aliyeva, R.A.1    Chyragov, F.M.2    Mahmudov, K.T.3
  • 80
    • 47249130913 scopus 로고    scopus 로고
    • Thermochemical characteristics of complexation of some ions with 3-(4-bromophenylazo) pentan-2,4-dione in aqueous ethanol
    • Gadjieva S.R., Mahmudov K.T., Pashaev F.H., Gasanov A.G., Chyragov F.M. Thermochemical characteristics of complexation of some ions with 3-(4-bromophenylazo) pentan-2,4-dione in aqueous ethanol. Russ. J. Coord. Chem. 2008, 34:536-541.
    • (2008) Russ. J. Coord. Chem. , vol.34 , pp. 536-541
    • Gadjieva, S.R.1    Mahmudov, K.T.2    Pashaev, F.H.3    Gasanov, A.G.4    Chyragov, F.M.5
  • 81
    • 70349574159 scopus 로고    scopus 로고
    • Copper(II) complex with 3-(2-hydroxy-3-sulfo-5-nitrophenylhydrazo)pentane-2,4-dione: synthesis and structure
    • Maharramov A.M., Aliyeva R.A., Mahmudov K.T., Kurbanov A.V., Askerov R.K. Copper(II) complex with 3-(2-hydroxy-3-sulfo-5-nitrophenylhydrazo)pentane-2,4-dione: synthesis and structure. Russ. J. Coord. Chem. 2009, 35:704-709.
    • (2009) Russ. J. Coord. Chem. , vol.35 , pp. 704-709
    • Maharramov, A.M.1    Aliyeva, R.A.2    Mahmudov, K.T.3    Kurbanov, A.V.4    Askerov, R.K.5
  • 82
    • 33947484873 scopus 로고
    • Azohydrazone conversion. II. The coupling of diazonium ion with β-diketones
    • Yao H.C. Azohydrazone conversion. II. The coupling of diazonium ion with β-diketones. J. Org. Chem. 1964, 29:2959-2962.
    • (1964) J. Org. Chem. , vol.29 , pp. 2959-2962
    • Yao, H.C.1
  • 83
    • 0011898823 scopus 로고
    • Single ion activity at high ionic strengths with ion-selective electrodes and the Debye-Hueckel equation
    • Uemasul I., Umezawa Y. Single ion activity at high ionic strengths with ion-selective electrodes and the Debye-Hueckel equation. Anal. Chem. 1983, 55:386-388.
    • (1983) Anal. Chem. , vol.55 , pp. 386-388
    • Uemasul, I.1    Umezawa, Y.2
  • 84
    • 0027933954 scopus 로고
    • Optimum composition of neutral carrier based pH electrodes
    • Bakker E., Xu A., Preitsch E. Optimum composition of neutral carrier based pH electrodes. Anal. Chim. Acta 1994, 295:253-262.
    • (1994) Anal. Chim. Acta , vol.295 , pp. 253-262
    • Bakker, E.1    Xu, A.2    Preitsch, E.3
  • 85
    • 0002441594 scopus 로고
    • Properties of PVC based membranes used in ion-selective electrodes
    • Armstrong R.D., Harvani G. Properties of PVC based membranes used in ion-selective electrodes. Electrochim. Acta 1990, 35:1-7.
    • (1990) Electrochim. Acta , vol.35 , pp. 1-7
    • Armstrong, R.D.1    Harvani, G.2
  • 86
    • 0000581279 scopus 로고
    • Chemically modified field effect transistors: the effect of ion-pair association on the membrane potentials
    • Cobben P.L.H.M., Egberink R.J.M., Bomer J.G., Bergveld P., Reinhoudt D.N. Chemically modified field effect transistors: the effect of ion-pair association on the membrane potentials. J. Electroanal. Chem. 1994, 368:193-208.
    • (1994) J. Electroanal. Chem. , vol.368 , pp. 193-208
    • Cobben, P.L.H.M.1    Egberink, R.J.M.2    Bomer, J.G.3    Bergveld, P.4    Reinhoudt, D.N.5
  • 88
    • 0039397277 scopus 로고
    • Theory and applications of ion-selective electrodes part II
    • Koryta J. Theory and applications of ion-selective electrodes part II. Anal. Chim. Acta 1972, 91:1-85.
    • (1972) Anal. Chim. Acta , vol.91 , pp. 1-85
    • Koryta, J.1
  • 89
    • 4544366331 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    • Bakker E., Buhlmann P., Pretsch E. Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics. Chem. Rev. 1997, 97:3083-3132.
    • (1997) Chem. Rev. , vol.97 , pp. 3083-3132
    • Bakker, E.1    Buhlmann, P.2    Pretsch, E.3
  • 90
    • 46549096850 scopus 로고
    • Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral carriers
    • Ammann D., Pretsch E., Simon W., Lindler E., Bezegh A., Pungor E. Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral carriers. Anal. Chim. Acta 1985, 171:119-129.
    • (1985) Anal. Chim. Acta , vol.171 , pp. 119-129
    • Ammann, D.1    Pretsch, E.2    Simon, W.3    Lindler, E.4    Bezegh, A.5    Pungor, E.6
  • 91
    • 0034000551 scopus 로고    scopus 로고
    • Lead-selective membrane potentiometric sensor based on a recently synthesized dimethyl benzo tetrathia fulvalene
    • Fathi M.R., Darviche F., Ganjali M.R. Lead-selective membrane potentiometric sensor based on a recently synthesized dimethyl benzo tetrathia fulvalene. Anal. Lett. 2000, 33:1025-1035.
    • (2000) Anal. Lett. , vol.33 , pp. 1025-1035
    • Fathi, M.R.1    Darviche, F.2    Ganjali, M.R.3
  • 92
    • 0032146532 scopus 로고    scopus 로고
    • Lead ion selective PVC membrane electrode based on 5,5′-dithiobis-(2-nitrobenzoic acid)
    • Rouhollahi A., Ganjali M.R., Shamsipur M. Lead ion selective PVC membrane electrode based on 5,5′-dithiobis-(2-nitrobenzoic acid). Talanta 1998, 46:1341-1346.
    • (1998) Talanta , vol.46 , pp. 1341-1346
    • Rouhollahi, A.1    Ganjali, M.R.2    Shamsipur, M.3
  • 93
    • 84996008912 scopus 로고
    • Distribution equilibria of five beta-diketones and their complexes of copper(III) and iron(III) in 4-methyl-2-pentanone-aqueous perchlorate solution systems
    • Sekine T., Inaba K., Morimoto T. Distribution equilibria of five beta-diketones and their complexes of copper(III) and iron(III) in 4-methyl-2-pentanone-aqueous perchlorate solution systems. Anal. Sci. 1986, 2:535-540.
    • (1986) Anal. Sci. , vol.2 , pp. 535-540
    • Sekine, T.1    Inaba, K.2    Morimoto, T.3
  • 94
    • 84930167786 scopus 로고
    • Recommendations for nomenclature of ionselective electrodes (IUPAC Recommendations 1994)
    • Buck R.P., Lindner E. Recommendations for nomenclature of ionselective electrodes (IUPAC Recommendations 1994). Pure Appl. Chem. 1994, 66:2527-2536.
    • (1994) Pure Appl. Chem. , vol.66 , pp. 2527-2536
    • Buck, R.P.1    Lindner, E.2
  • 95
    • 84956088296 scopus 로고
    • Commission on analytical nomenclature. Recommendations for Nomenclature of ion selective electrodes
    • Analytical Chemistry Devision I.U.P.A.C.
    • Analytical Chemistry Devision IUPAC. Commission on analytical nomenclature. Recommendations for Nomenclature of ion selective electrodes. Pure Appl. Chem. 1976, 48:127-132.
    • (1976) Pure Appl. Chem. , vol.48 , pp. 127-132
  • 97
    • 17844399370 scopus 로고
    • Determination of selectivity coefficients of ion-selective electrodes by a matched-potential method
    • Gadzepko V.P., Christian G.D. Determination of selectivity coefficients of ion-selective electrodes by a matched-potential method. Anal. Chim. Acta 1984, 164:279-282.
    • (1984) Anal. Chim. Acta , vol.164 , pp. 279-282
    • Gadzepko, V.P.1    Christian, G.D.2
  • 99
    • 0002232006 scopus 로고    scopus 로고
    • Selectivity of liquid membrane ion-selective electrodes
    • Bakker E. Selectivity of liquid membrane ion-selective electrodes. Electroanalysis 1997, 9:7-12.
    • (1997) Electroanalysis , vol.9 , pp. 7-12
    • Bakker, E.1
  • 100
    • 33947298243 scopus 로고
    • Selectivity studies on liquid membrane, ion-selective electrodes
    • Srinivasan K., Rechnitz G.A. Selectivity studies on liquid membrane, ion-selective electrodes. Anal. Chem. 1969, 41:1203-1208.
    • (1969) Anal. Chem. , vol.41 , pp. 1203-1208
    • Srinivasan, K.1    Rechnitz, G.A.2
  • 101
    • 37049082025 scopus 로고
    • Mercury(II) and silver(I) ion-selective electrodes based on dithiacrown ethers
    • Lai M.T., Shih J.S. Mercury(II) and silver(I) ion-selective electrodes based on dithiacrown ethers. Analyst 1986, 111:891-896.
    • (1986) Analyst , vol.111 , pp. 891-896
    • Lai, M.T.1    Shih, J.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.