메뉴 건너뛰기




Volumn 38, Issue 2, 2011, Pages 553-555

It is STILL necessary to validate each individual IMRT treatment plan with dosimetric measurements before delivery

Author keywords

[No Author keywords available]

Indexed keywords

TREATMENT PLANS;

EID: 79551668416     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3512801     Document Type: Note
Times cited : (30)

References (9)
  • 1
    • 69649105188 scopus 로고    scopus 로고
    • Task Group 142 report: Quality assurance of medical accelerators
    • MPHYA6 0094-2405,. 10.1118/1.3190392
    • E. E. Klein, " Task Group 142 report: Quality assurance of medical accelerators.," Med. Phys. MPHYA6 0094-2405 36, 4197-4212 (2009). 10.1118/1.3190392
    • (2009) Med. Phys. , vol.36 , pp. 4197-4212
    • Klein, E.E.1
  • 2
    • 85027231275 scopus 로고    scopus 로고
    • AAPM 47th Annual AAPM Meeting, Seattle, WA, (unpublished), AAPM Virtual Library.
    • G. Sherouse, " Why, what and how much QA is necessary for IMRT?," AAPM 47th Annual AAPM Meeting, Seattle, WA, 2005 (unpublished), AAPM Virtual Library (http://www.blueskybroadcast.com/Client/AAPM-annual05/ trans/aapm-a41-sherouse.pdf).
    • (2005) Why, What and How Much QA Is Necessary for IMRT?
    • Sherouse, G.1
  • 3
    • 77954706609 scopus 로고    scopus 로고
    • The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors
    • MPHYA6 0094-2405,. 10.1118/1.3453576
    • A. Rangel, " The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors.," Med. Phys. MPHYA6 0094-2405 37, 3862-3867 (2010). 10.1118/1.3453576
    • (2010) Med. Phys. , vol.37 , pp. 3862-3867
    • Rangel, A.1
  • 6
    • 77953487894 scopus 로고    scopus 로고
    • On the insensitivity of single field planar dosimetry to IMRT inaccuracies
    • MPHYA6 0094-2405,. 10.1118/1.3425781
    • J. J. Kruse, " On the insensitivity of single field planar dosimetry to IMRT inaccuracies.," Med. Phys. MPHYA6 0094-2405 37, 2516-2524 (2010). 10.1118/1.3425781
    • (2010) Med. Phys. , vol.37 , pp. 2516-2524
    • Kruse, J.J.1
  • 7
    • 41749124562 scopus 로고    scopus 로고
    • Challenges in credentialing institutions and participants in advanced technology multi-institutional clinical trials
    • IOBPD3 0360-3016,. 10.1016/j.ijrob2007.08.083
    • G. S. Ibbott, " Challenges in credentialing institutions and participants in advanced technology multi-institutional clinical trials.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 71, S71-S75 (2008). 10.1016/j.ijrobp.2007.08.083
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.71
    • Ibbott, G.S.1
  • 8
    • 67049107499 scopus 로고    scopus 로고
    • Evaluation of safety in a radiation oncology setting using failure mode and effects analysis
    • IOBPD3 0360-3016,. 10.1016/j.ijrob2008.10.038
    • E. C. Ford, " Evaluation of safety in a radiation oncology setting using failure mode and effects analysis.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 74, 852-858 (2009). 10.1016/j.ijrobp.2008.10.038
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.74 , pp. 852-858
    • Ford, E.C.1
  • 9
    • 77953520249 scopus 로고    scopus 로고
    • Catching errors with in vivo EPID dosimetry
    • MPHYA6 0094-2405,. 10.1118/1.3397807
    • A. Mans, " Catching errors with in vivo EPID dosimetry.," Med. Phys. MPHYA6 0094-2405 37, 2638-2644 (2010). 10.1118/1.3397807
    • (2010) Med. Phys. , vol.37 , pp. 2638-2644
    • Mans, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.