메뉴 건너뛰기




Volumn 14, Issue 4, 2010, Pages 185-187

Use of the pro-seal laryngeal mask airway facilitates percutaneous dilatational tracheostomy in an intensive care unit

Author keywords

Laryngeal mask airway; percutaneous tracheostomy; pro seal laryngeal mask airway

Indexed keywords

ARTICLE; BREATHING; BRONCHOSCOPY; ENDOTRACHEAL TUBE; FIBEROSCOPE; GLOTTIS; HUMAN; INTENSIVE CARE UNIT; LARYNGEAL MASK; MAJOR CLINICAL STUDY; TIDAL VOLUME; TRACHEOSTOMY;

EID: 79551650124     PISSN: 09725229     EISSN: 1998359X     Source Type: Journal    
DOI: 10.4103/0972-5229.76082     Document Type: Article
Times cited : (6)

References (15)
  • 1
    • 0021875967 scopus 로고
    • Elective percutaneous dilatational tracheostomy: A new simple bedside procedure: Preliminary report
    • Ciaglia P, Firsching R, Syniec C. Elective percutaneous dilatational tracheostomy: A new simple bedside procedure: Preliminary report. Chest 1985;87:715-9.
    • (1985) Chest , vol.87 , pp. 715-719
    • Ciaglia, P.1    Firsching, R.2    Syniec, C.3
  • 2
    • 0033398051 scopus 로고    scopus 로고
    • Percutaneous tracheostomy in the intensive care unit
    • Mercer M, Manara AR. Percutaneous tracheostomy in the intensive care unit. Curr Opin Anaesthesiol 1999;12:701-6.
    • (1999) Curr Opin Anaesthesiol , vol.12 , pp. 701-706
    • Mercer, M.1    Manara, A.R.2
  • 3
    • 0032983980 scopus 로고    scopus 로고
    • Percutaneous dilatational tracheostomy under the microscope: Justification for intra-procedural bronchoscop
    • Reilly PM, Shapiro MB, Malcynski JT. Percutaneous dilatational tracheostomy under the microscope: justification for intra-procedural bronchoscop. Intensive Care Med 1999;25:3-4.
    • (1999) Intensive Care Med , vol.25 , pp. 3-4
    • Reilly, P.M.1    Shapiro, M.B.2    Malcynski, J.T.3
  • 4
    • 79551625546 scopus 로고    scopus 로고
    • Inadvertent entry of a guide wire through the Murphy's eye causing difficulty in passing a percutaneous tracheostomy tube with seldinger technique: A case Report
    • Channa AB, Hussain A, Nawaz S, Al-Kendi M. Inadvertent entry of a guide wire through the Murphy's eye causing difficulty in passing a percutaneous tracheostomy tube with seldinger technique: A case Report. Internet J Anesthesiol 1092-406X.
    • Internet J Anesthesiol
    • Channa, A.B.1    Hussain, A.2    Nawaz, S.3    Al-Kendi, M.4
  • 5
    • 0027979941 scopus 로고
    • The laryngeal mask airway: A method to improve visualisation of the trachea and larynx during fibreoptic assisted percutaneous tracheostomy
    • Dexter TJ. The laryngeal mask airway: A method to improve visualisation of the trachea and larynx during fibreoptic assisted percutaneous tracheostomy. Anaesth Intensive Care 1994;22:35-9.
    • (1994) Anaesth Intensive Care , vol.22 , pp. 35-39
    • Dexter, T.J.1
  • 6
    • 0030638747 scopus 로고    scopus 로고
    • The use of the laryngeal mask airway in suitable ICU patients undergoing percutaneous dilational tracheostomy
    • Zuleika M, Jacobs S, Mphanza T, Brohi F. The use of the laryngeal mask airway in suitable ICU patients undergoing percutaneous dilational tracheostomy. Intensive Care Med 1997;23:129-30.
    • (1997) Intensive Care Med , vol.23 , pp. 129-130
    • Zuleika, M.1    Jacobs, S.2    Mphanza, T.3    Brohi, F.4
  • 7
    • 0036163319 scopus 로고    scopus 로고
    • The use of the laryngeal mask airway as an alternative to the endotracheal tube during percutaneous dilatational tracheostomy
    • Dosemeci L, Yilmaz M, Gurpinar F, Ramazanoglu A. The use of the laryngeal mask airway as an alternative to the endotracheal tube during percutaneous dilatational tracheostomy. Intensive Care Med 2002;28:63-7.
    • (2002) Intensive Care Med , vol.28 , pp. 63-67
    • Dosemeci, L.1    Yilmaz, M.2    Gurpinar, F.3    Ramazanoglu, A.4
  • 8
    • 0031709888 scopus 로고    scopus 로고
    • Airway control during percutaneous dilatational tracheostomy: Pilot study with the intubating laryngeal mask airway
    • Veghese C, Rangasami J, Kapila A, Parke T. Airway control during percutaneous dilatational tracheostomy: Pilot study with the intubating laryngeal mask airway. Br J Anaesth 1998;81:608-9.
    • (1998) Br J Anaesth , vol.81 , pp. 608-609
    • Veghese, C.1    Rangasami, J.2    Kapila, A.3    Parke, T.4
  • 10
    • 0034110143 scopus 로고    scopus 로고
    • The LMA 'Pro-Seal' a laryngeal mask with an oesophageal vent
    • Brain AIJ, Verghese C, Strube PJ. The LMA 'Pro-Seal' a laryngeal mask with an oesophageal vent. Br J Anaesth 2000;84:650-4.
    • (2000) Br J Anaesth , vol.84 , pp. 650-654
    • Brain, A.I.J.1    Verghese, C.2    Strube, P.J.3
  • 11
    • 0036209037 scopus 로고    scopus 로고
    • A randomized crossover comparison of the ProSeal with the classic laryngeal mask airway in unparalysed anaesthetized patients
    • Cook TM, Nolan JP, Verghese C, Strube PJ, Lees M, Millar JM, et al. A randomized crossover comparison of the ProSeal with the classic laryngeal mask airway in unparalysed anaesthetized patients. Br J Anaesth 2002;88:527-33.
    • (2002) Br J Anaesth , vol.88 , pp. 527-533
    • Cook, T.M.1    Nolan, J.P.2    Verghese, C.3    Strube, P.J.4    Lees, M.5    Millar, J.M.6
  • 12
    • 21544449115 scopus 로고    scopus 로고
    • Estimating the mean and variance from the median, range, and the size of a sample
    • Hozo SP, Djulbegovic B, Hozo I. Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol 2005;5:13.
    • (2005) BMC Med Res Methodol , vol.5 , pp. 13
    • Hozo, S.P.1    Djulbegovic, B.2    Hozo, I.3
  • 13
    • 0033795102 scopus 로고    scopus 로고
    • Does the ProSeal laryngeal mask airway prevent aspiration of regurgitated fluid?
    • Keller C, Brimacombe J, Kleinsasser A, Loekinger A. Does the ProSeal laryngeal mask airway prevent aspiration of regurgitated fluid? Anesth Analg 2000;91:1017-20.
    • (2000) Anesth Analg , vol.91 , pp. 1017-1020
    • Keller, C.1    Brimacombe, J.2    Kleinsasser, A.3    Loekinger, A.4
  • 15
    • 0037285949 scopus 로고    scopus 로고
    • trad after vomiting: A case report
    • trad after vomiting: A case report. Can J Anesth 2003;50:78-80.
    • (2003) Can J Anesth , vol.50 , pp. 78-80
    • Mark, D.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.