메뉴 건너뛰기




Volumn 98, Issue 4, 2011, Pages

Silicon nanowires for high-specificity and high-selectivity sensors under low-frequency scanning

Author keywords

[No Author keywords available]

Indexed keywords

FREQUENCY SCANNING; HIGH SPECIFICITY; LOW FREQUENCY; REFERENCE CHANNELS; SCANNING FREQUENCY; SI NANOWIRE; SIGNAL AMPLITUDE; SILICON NANOWIRES; SINGLE-CRYSTALLINE;

EID: 79551649143     PISSN: 00036951     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.3549067     Document Type: Article
Times cited : (5)

References (24)
  • 3
  • 4
    • 0035902938 scopus 로고    scopus 로고
    • Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species
    • DOI 10.1126/science.1062711
    • Y. Cui, Q. Wei, H. Park, and C. M. Lieber, Science 0036-8075 293, 1289 (2001). 10.1126/science.1062711 (Pubitemid 32777412)
    • (2001) Science , vol.293 , Issue.5533 , pp. 1289-1292
    • Cui, Y.1    Wei, Q.2    Park, H.3    Lieber, C.M.4
  • 6
    • 15544374415 scopus 로고    scopus 로고
    • Chemical detection with a single-walled carbon nanotube capacitor
    • DOI 10.1126/science.1109128
    • E. S. Snow, F. K. Perkins, E. J. Houser, S. C. Badescu, and T. L. Reinecke, Science 0036-8075 307, 1942 (2005). 10.1126/science.1109128 (Pubitemid 40404700)
    • (2005) Science , vol.307 , Issue.5717 , pp. 1942-1945
    • Snow, E.S.1    Perkins, F.K.2    Houser, E.J.3    Badescu, S.C.4    Reinecke, T.L.5
  • 7
    • 0033689922 scopus 로고    scopus 로고
    • 0935-9648, 10.1002/1521-4095(200006)12:12<878::AID-ADMA878>3.0. CO;2-X
    • M. P. Zach and R. M. Penner, Adv. Mater. 0935-9648 12, 878 (2000). 10.1002/1521-4095(200006)12:12<878::AID-ADMA878>3.0.CO;2-X
    • (2000) Adv. Mater. , vol.12 , pp. 878
    • Zach, M.P.1    Penner, R.M.2
  • 8
    • 33845644646 scopus 로고    scopus 로고
    • Scaling properties of gold nanocluster chemiresistor sensors
    • DOI 10.1109/JSEN.2006.884447
    • M. G. Ancona, A. W. Snow, E. E. Foos, W. Kruppa, and R. Bass, IEEE Sens. J. 1530-437X 6, 1403 (2006). 10.1109/JSEN.2006.884447 (Pubitemid 44955715)
    • (2006) IEEE Sensors Journal , vol.6 , Issue.6 , pp. 1403-1413
    • Ancona, M.G.1    Snow, A.W.2    Foos, E.E.3    Kruppa, W.4    Bass, R.5
  • 10
    • 0032498174 scopus 로고    scopus 로고
    • A laser ablation method for the synthesis of crystalline semiconductor nanowires
    • DOI 10.1126/science.279.5348.208
    • A. Morales and C. M. Lieber, Science 0036-8075 279, 208 (1998). 10.1126/science.279.5348.208 (Pubitemid 28103874)
    • (1998) Science , vol.279 , Issue.5348 , pp. 208-211
    • Morales, A.M.1    Lieber, C.M.2
  • 11
    • 0037459371 scopus 로고    scopus 로고
    • Small-diameter silicon nanowire surfaces
    • DOI 10.1126/science.1080313
    • D. D. D. Ma, C. S. Lee, F. C. K. Au, D. S. Y. Tong, and S. -T. Lee Science 0036-8075 299, 1874 (2003). 10.1126/science.1080313 (Pubitemid 36356653)
    • (2003) Science , vol.299 , Issue.5614 , pp. 1874-1877
    • Ma, D.D.D.1    Lee, C.S.2    Au, F.C.K.3    Tong, S.Y.4    Lee, S.T.5
  • 12
    • 1442275478 scopus 로고    scopus 로고
    • Sequence-Specific Label-Free DNA Sensors Based on Silicon Nanowires
    • DOI 10.1021/nl034958e
    • Z. Li, Y. Chen, T. I. Kamins, K. Nauka, and R. S. Williams, Nano Lett. 1530-6984 4, 245 (2004). 10.1021/nl034958e (Pubitemid 38292895)
    • (2004) Nano Letters , vol.4 , Issue.2 , pp. 245-247
    • Li, Z.1    Chen, Y.2    Li, X.3    Kamins, T.I.4    Nauka, K.5    Williams, R.S.6
  • 17
    • 24644479720 scopus 로고    scopus 로고
    • Silicon nanowire sensors for bioanalytical applications: Glucose and hydrogen peroxide detection
    • DOI 10.1002/adfm.200500080
    • M. -W. Shao, Y. -Y Shan, N. -B. Wong, and S. -T. Lee, Adv. Funct. Mater. 1616-301X 15, 1478 (2005). 10.1002/adfm.200500080 (Pubitemid 41284828)
    • (2005) Advanced Functional Materials , vol.15 , Issue.9 , pp. 1478-1482
    • Shao, M.-W.1    Shan, Y.-Y.2    Wong, N.-B.3    Lee, S.-T.4
  • 18
    • 79551621034 scopus 로고    scopus 로고
    • See supplementary material at E-APPLAB-98-008105 for experimental details, H-SiNW characterization and sensor setup, more low-frequency scanning text results for water detection, derivation, and analysis of the equivalent circuit, and the detailed theoretical calculation and analysis for peak width and dipole difference
    • See supplementary material at http://dx.doi.org/10.1063/1.3549067 E-APPLAB-98-008105 for experimental details, H-SiNW characterization and sensor setup, more low-frequency scanning text results for water detection, derivation, and analysis of the equivalent circuit, and the detailed theoretical calculation and analysis for peak width and dipole difference.
  • 19
    • 79551645707 scopus 로고    scopus 로고
    • Virtual instrument see
    • Virtual instrument see: http://www.virtins.com.
  • 20
    • 0042281899 scopus 로고    scopus 로고
    • 0924-4247, 10.1016/S0924-4247(03)00231-0
    • D. G. Yarkin, Sens. Actuators, A 0924-4247 107, 1 (2003). 10.1016/S0924-4247(03)00231-0
    • (2003) Sens. Actuators, A , vol.107 , pp. 1
    • Yarkin, D.G.1
  • 22
    • 0000730460 scopus 로고    scopus 로고
    • 0556-2805, 10.1103/PhysRevB.53.R10441
    • P. Ordejón, E. Artacho, and J. M. Soler, Phys. Rev. B 0556-2805 53, R10441 (1996). 10.1103/PhysRevB.53.R10441
    • (1996) Phys. Rev. B , vol.53 , pp. 10441
    • Ordejón, P.1    Artacho, E.2    Soler, J.M.3
  • 23
    • 10644250257 scopus 로고
    • 0031-899X, 10.1103/PhysRev.136.B864
    • P. Hohenberg and W. Kohn, Phys. Rev. 0031-899X 136, B864 (1964). 10.1103/PhysRev.136.B864
    • (1964) Phys. Rev. , vol.136 , pp. 864
    • Hohenberg, P.1    Kohn, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.