메뉴 건너뛰기




Volumn 6, Issue 2, 2011, Pages 195-203

Elastic phantoms generated by microfluidics technology: Validation of an imaged-based approach for accurate measurement of the growth rate of lung nodules

Author keywords

Elastic phantoms; Growth rate; Lung cancer; Microfluidics; Validation

Indexed keywords

ACCURATE MEASUREMENT; APPEARANCE MODELS; COMPUTED TOMOGRAPHY; CONTROL GROUPS; DATA REGISTRATION; ELASTIC PHANTOMS; GROUND TRUTH; IN-VIVO; LOCAL ALIGNMENT; LOW DOSE; LUNG CANCER; LUNG NODULE; LUNG PHANTOM; MICROFLUIDICS TECHNOLOGY; NEW APPROACHES; NON-RIGID; POLYDIMETHYLSILOXANE PDMS; RELATIVE DEFORMATION; TRANSPARENT POLYMER; VALIDATION;

EID: 79551628217     PISSN: 18606768     EISSN: 18607314     Source Type: Journal    
DOI: 10.1002/biot.201000105     Document Type: Article
Times cited : (31)

References (33)
  • 1
    • 79551628108 scopus 로고    scopus 로고
    • American Cancer Society: Cancer Facts and Figures, 2006.
    • American Cancer Society: Cancer Facts and Figures, 2006.
  • 2
    • 9344257538 scopus 로고    scopus 로고
    • Managing the small pulmonary nodule discovered by CT.
    • Libby, D. M., Smith, J. P., Altorki, N. K., Pasmantier, M. W. et al., Managing the small pulmonary nodule discovered by CT. Chest 2004, 125, 1522-1530.
    • (2004) Chest , vol.125 , pp. 1522-1530
    • Libby, D.M.1    Smith, J.P.2    Altorki, N.K.3    Pasmantier, M.W.4
  • 3
    • 37349067412 scopus 로고    scopus 로고
    • Measurement methods for small pulmonary nodules.
    • Reeves, A. P., Measurement methods for small pulmonary nodules. Radiology 2008, 246, 333-334.
    • (2008) Radiology , vol.246 , pp. 333-334
    • Reeves, A.P.1
  • 4
    • 0034491707 scopus 로고    scopus 로고
    • Growth rate of small lung cancers detected on mass CT screening.
    • Hasegawa, M., Sone, S., Takashima, S., Li, F. et al., Growth rate of small lung cancers detected on mass CT screening. Br. J. Radiol. 2000, 73, 1252-1259.
    • (2000) Br. J. Radiol. , vol.73 , pp. 1252-1259
    • Hasegawa, M.1    Sone, S.2    Takashima, S.3    Li, F.4
  • 5
    • 33745953240 scopus 로고    scopus 로고
    • Measures of response: RECIST, WHO, and new alternatives.
    • Jaffe, C. C., Measures of response: RECIST, WHO, and new alternatives. J. Clin. Oncol. 2006, 24, 3245-3251.
    • (2006) J. Clin. Oncol. , vol.24 , pp. 3245-3251
    • Jaffe, C.C.1
  • 6
    • 0028300771 scopus 로고
    • Computerized detection of pulmonary nodules in computed tomography images.
    • Giger, M. L., Bae, K. T., MacMahon, H., Computerized detection of pulmonary nodules in computed tomography images. Invest. Radiol. 1994, 29, 459-465.
    • (1994) Invest. Radiol. , vol.29 , pp. 459-465
    • Giger, M.L.1    Bae, K.T.2    MacMahon, H.3
  • 7
    • 0001054136 scopus 로고    scopus 로고
    • Computer aided diagnosis system for lung cancer based on helical CT images.
    • Toshioka, S., Kanazawa, K., Niki, N., Satoh, H. et al., Computer aided diagnosis system for lung cancer based on helical CT images. Int. Soc. Opt. Eng. 1997, 3034, 975-984.
    • (1997) Int. Soc. Opt. Eng. , vol.3034 , pp. 975-984
    • Toshioka, S.1    Kanazawa, K.2    Niki, N.3    Satoh, H.4
  • 8
    • 0032981748 scopus 로고    scopus 로고
    • A pattern classification approach to characterizing solitary pulmonary nodules imaged on high resolution CT: Preliminary results.
    • McNitt-Gray, M. F., Hart, E. M., Wyckoff, N., Sayre, J. W. et al., A pattern classification approach to characterizing solitary pulmonary nodules imaged on high resolution CT: Preliminary results. Med. Phys. 1999, 26, 880-888.
    • (1999) Med. Phys. , vol.26 , pp. 880-888
    • McNitt-Gray, M.F.1    Hart, E.M.2    Wyckoff, N.3    Sayre, J.W.4
  • 9
    • 0032981298 scopus 로고    scopus 로고
    • Two-dimensional multi-criterion segmentation of pulmonary nodules on helical CT images.
    • Zhao, B., Yankelevitz, D. F., Reeves, A. P., Henschke, C. I., Two-dimensional multi-criterion segmentation of pulmonary nodules on helical CT images. Med. Phys. 1999, 26, 889-895.
    • (1999) Med. Phys. , vol.26 , pp. 889-895
    • Zhao, B.1    Yankelevitz, D.F.2    Reeves, A.P.3    Henschke, C.I.4
  • 10
    • 0032765011 scopus 로고    scopus 로고
    • Small pulmonary nodules: Evaluation with repeat CT-preliminary experience.
    • Yankelevitz, D. F., Gupta, R., Zhao, B., Henschke, C. I., Small pulmonary nodules: Evaluation with repeat CT-preliminary experience. Radiology 1999, 212, 561-566.
    • (1999) Radiology , vol.212 , pp. 561-566
    • Yankelevitz, D.F.1    Gupta, R.2    Zhao, B.3    Henschke, C.I.4
  • 11
    • 0034538087 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation.
    • Yankelevitz, D. F., Reeves, A. P., Kostis, W. J., Zhao, B. et al., Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation. Radiology 2000, 217, 251-256.
    • (2000) Radiology , vol.217 , pp. 251-256
    • Yankelevitz, D.F.1    Reeves, A.P.2    Kostis, W.J.3    Zhao, B.4
  • 12
    • 57649227433 scopus 로고    scopus 로고
    • Shape analysis of pulmonary nodules based on thin section CT images.
    • Kawata, Y., Niki, N., Ohmatsu, H., Eguchi, K. et al., Shape analysis of pulmonary nodules based on thin section CT images. Med. Imaging: Image Process. SPIE 1997, 3034, 964-974.
    • (1997) Med. Imaging: Image Process. SPIE , vol.3034 , pp. 964-974
    • Kawata, Y.1    Niki, N.2    Ohmatsu, H.3    Eguchi, K.4
  • 13
    • 2142812310 scopus 로고    scopus 로고
    • Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT.
    • Kostis, W. J., Yankelevitz, D. F., Reeves, A. P., Fluture, S. C. et al., Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT. Radiology 2004, 231, 446-452.
    • (2004) Radiology , vol.231 , pp. 446-452
    • Kostis, W.J.1    Yankelevitz, D.F.2    Reeves, A.P.3    Fluture, S.C.4
  • 15
    • 0033690008 scopus 로고    scopus 로고
    • Tracking interval changes of pulmonary nodules using a sequence of three-dimensional thoracic images.
    • Kawata, Y., Niki, N., Omatsu, H., Kusumoto, M. et al., Tracking interval changes of pulmonary nodules using a sequence of three-dimensional thoracic images. Med. Imaging: Image Process. SPIE 2000, 3979, 86-96.
    • (2000) Med. Imaging: Image Process. SPIE , vol.3979 , pp. 86-96
    • Kawata, Y.1    Niki, N.2    Omatsu, H.3    Kusumoto, M.4
  • 16
    • 17944373384 scopus 로고    scopus 로고
    • Analysis of evolving processes in pulmonary nodules using a sequence of three-dimensional thoracic images.
    • Kawata, Y., Niki, N., Omatsu, H., Kusumoto, M. et al., Analysis of evolving processes in pulmonary nodules using a sequence of three-dimensional thoracic images. Med. Imaging: Image Process. SPIE 2001, 4322, 1890-1901.
    • (2001) Med. Imaging: Image Process. SPIE , vol.4322 , pp. 1890-1901
    • Kawata, Y.1    Niki, N.2    Omatsu, H.3    Kusumoto, M.4
  • 17
    • 79551632121 scopus 로고    scopus 로고
    • Zheng, Y., Steiner, K., Bauer, T., Yu, J., et al., Lung nodule growth analysis from 3D CT Data with a Coupled Segmentation and registration framework. IEEE Int. Conf. Comput. Vis. ICCV 2009, 1-8.
    • Zheng, Y., Steiner, K., Bauer, T., Yu, J., et al., Lung nodule growth analysis from 3D CT Data with a Coupled Segmentation and registration framework. IEEE Int. Conf. Comput. Vis. ICCV 2009, 1-8.
  • 18
    • 70449403418 scopus 로고    scopus 로고
    • Jirapatnakul, A. C., Reeves, A. P., Biancardi, A. M., Yankelevitz, D. F., et al., Semi-automated measurement of pulmonary nodule growth without explicit segmentation. IEEE Int. Symp. BioMed. Imaging ISBI 2009, 855-858.
    • Jirapatnakul, A. C., Reeves, A. P., Biancardi, A. M., Yankelevitz, D. F., et al., Semi-automated measurement of pulmonary nodule growth without explicit segmentation. IEEE Int. Symp. BioMed. Imaging ISBI 2009, 855-858.
  • 19
    • 0842345498 scopus 로고    scopus 로고
    • Volumetric measurements of pulmonary nodules at multi-row detector CT: In-vivo reproducibility.
    • Wormanns, D., Kohl, G., Klotz, E., Marheine, A. et al., Volumetric measurements of pulmonary nodules at multi-row detector CT: In-vivo reproducibility. Eur Radiol. 2004, 14, 86-92.
    • (2004) Eur Radiol. , vol.14 , pp. 86-92
    • Wormanns, D.1    Kohl, G.2    Klotz, E.3    Marheine, A.4
  • 20
    • 2142700841 scopus 로고    scopus 로고
    • Pulmonary Nodules: Preliminary experience with three-dimensional evaluation.
    • Revel, M., Lefort, C., Bissery, A., Bienvenu, M. et al., Pulmonary Nodules: Preliminary experience with three-dimensional evaluation. Radiology 2004, 231, 459-466.
    • (2004) Radiology , vol.231 , pp. 459-466
    • Revel, M.1    Lefort, C.2    Bissery, A.3    Bienvenu, M.4
  • 21
    • 0036099035 scopus 로고    scopus 로고
    • Volumetric growth rate of stage I lung cancer prior to treatment: Serial CT scanning.
    • Winer-Muram, H. T., Jennings, S. G., Tarver, R. D., Aisen, A. M. et al., Volumetric growth rate of stage I lung cancer prior to treatment: Serial CT scanning. Radiology 2002, 223, 798-805.
    • (2002) Radiology , vol.223 , pp. 798-805
    • Winer-Muram, H.T.1    Jennings, S.G.2    Tarver, R.D.3    Aisen, A.M.4
  • 22
    • 33750380261 scopus 로고    scopus 로고
    • Distribution of stage I lung cancer growth rates determined with serial volumetric CT measurements.
    • Jennings, S. G., Winer-Muram, H. T., Tann, M., Ying, J., Dowdeswell, I., Distribution of stage I lung cancer growth rates determined with serial volumetric CT measurements. Radiology 2006, 241, 554-563.
    • (2006) Radiology , vol.241 , pp. 554-563
    • Jennings, S.G.1    Winer-Muram, H.T.2    Tann, M.3    Ying, J.4    Dowdeswell, I.5
  • 23
    • 67049145084 scopus 로고    scopus 로고
    • Pulmonary nodules: Volume repeatability at multidetector CT lung cancer screening.
    • Marchianò, A., Calabrò, E., Civelli, E., Tolla, G. D. et al., Pulmonary nodules: Volume repeatability at multidetector CT lung cancer screening. Radiology 2009, 251, 919-925.
    • (2009) Radiology , vol.251 , pp. 919-925
    • Marchianò, A.1    Calabrò, E.2    Civelli, E.3    Tolla, G.D.4
  • 24
    • 18844382442 scopus 로고    scopus 로고
    • Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy.
    • Goo, J., Tongdee, T., Tongdee, R., Yeo, K. et al., Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy. Radiology 2005, 235, 850-856.
    • (2005) Radiology , vol.235 , pp. 850-856
    • Goo, J.1    Tongdee, T.2    Tongdee, R.3    Yeo, K.4
  • 25
    • 0042931348 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volume measurement at chest CT-phantom study.
    • Ko, J. P., Rusinek H., Jacobs, E. L., Babb, J. S, et al., Small pulmonary nodules: Volume measurement at chest CT-phantom study. Radiology 2003, 228, 864-870.
    • (2003) Radiology , vol.228 , pp. 864-870
    • Ko, J.P.1    Rusinek, H.2    Jacobs, E.L.3    Babb, J.S.4
  • 26
    • 3042682023 scopus 로고    scopus 로고
    • Theoretical prediction of lung nodule measurement accuracy under different acquisition and reconstruction conditions.
    • Jiang, H., Kelly, K., Theoretical prediction of lung nodule measurement accuracy under different acquisition and reconstruction conditions. Med. Imaging: Physiol. Funct. Struct. Med. Images 2004, 5369, 406-412.
    • (2004) Med. Imaging: Physiol. Funct. Struct. Med. Images , vol.5369 , pp. 406-412
    • Jiang, H.1    Kelly, K.2
  • 27
    • 64949119251 scopus 로고    scopus 로고
    • Noncalcified lung nodules: Volumetric assessment with thoracic CT.
    • Gavrielides, M. A., Kinnard, L. M., Myers, K. J., Petrick, N., Noncalcified lung nodules: Volumetric assessment with thoracic CT. Radiology 2009, 251, 26-37.
    • (2009) Radiology , vol.251 , pp. 26-37
    • Gavrielides, M.A.1    Kinnard, L.M.2    Myers, K.J.3    Petrick, N.4
  • 28
    • 51949107060 scopus 로고    scopus 로고
    • El-Baz, A., Gimel'farb, G., Image segmentation with a parametric deformable model using shape and appearance priors. IEEE Conf. Comput. Vis. Pattern Recog. CVPR 2008, 1-8.
    • El-Baz, A., Gimel'farb, G., Image segmentation with a parametric deformable model using shape and appearance priors. IEEE Conf. Comput. Vis. Pattern Recog. CVPR 2008, 1-8.
  • 29
    • 59149087264 scopus 로고    scopus 로고
    • Automatic analysis of 3D low dose CT images for early diagnosis of lung cancer.
    • El-Baz, A., Gimel'farb, G., Falk, R., Abo El-Ghar, M., Automatic analysis of 3D low dose CT images for early diagnosis of lung cancer. Pattern Recog. J. 2009, 42, 1041-1051.
    • (2009) Pattern Recog. J. , vol.42 , pp. 1041-1051
    • El-Baz, A.1    Gimel'farb, G.2    Falk, R.3    Abo El-Ghar, M.4
  • 30
    • 79551646565 scopus 로고    scopus 로고
    • Gimel'farb, G., Image textures and Gibbs random fields. Kluwer: Dordrecht, 1999.
    • Gimel'farb, G., Image textures and Gibbs random fields. Kluwer: Dordrecht, 1999.
  • 31
    • 77953178238 scopus 로고    scopus 로고
    • El-Baz, A., Gimel'farb, G., Robust image segmentation using learned priors. IEEE Int. Conf. Comput. Vis. ICCV 2009, 857-864.
    • El-Baz, A., Gimel'farb, G., Robust image segmentation using learned priors. IEEE Int. Conf. Comput. Vis. ICCV 2009, 857-864.
  • 32
    • 48149107192 scopus 로고    scopus 로고
    • EM based approximation of empirical distributions with linear combinations of discrete Gaussians.
    • El-Baz, A., Gimel'farb, G., EM based approximation of empirical distributions with linear combinations of discrete Gaussians. IEEE Int. Conf. Image Process. 2007, 4, 373-376.
    • (2007) IEEE Int. Conf. Image Process. , vol.4 , pp. 373-376
    • El-Baz, A.1    Gimel'farb, G.2
  • 33
    • 0029966538 scopus 로고    scopus 로고
    • Fast marching level set method for monotonically advancing fronts.
    • Sethian, J., Fast marching level set method for monotonically advancing fronts. Proc. Natl. Acad. Sci. USA 1996, 93, 1591-1595.
    • (1996) Proc. Natl. Acad. Sci. USA , vol.93 , pp. 1591-1595
    • Sethian, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.