메뉴 건너뛰기




Volumn 30, Issue 2, 2011, Pages 203-214

An imaging model incorporating ultrasonic transducer properties for three-dimensional optoacoustic tomography

Author keywords

Optoacoustic tomography (OAT); photoacoustic tomography (PCT); thermoacoustic tomography

Indexed keywords

DISCRETE FORM; IMAGE BLURRING; IMAGING MODALITY; IMAGING MODEL; ITERATIVE RECONSTRUCTION; MEASUREMENT DATA; MEASUREMENT GEOMETRY; NUMERICAL PROPERTIES; OPTOACOUSTIC TOMOGRAPHY; PHOTOACOUSTIC TOMOGRAPHY; RECONSTRUCTED IMAGE; RECONSTRUCTION ALGORITHMS; SPATIAL RESOLUTION; TEMPORAL RESPONSE; THERMOACOUSTIC TOMOGRAPHY; ULTRASOUND IMAGING; ULTRASOUND TRANSDUCERS;

EID: 79551582829     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2010.2072514     Document Type: Article
Times cited : (165)

References (44)
  • 2
    • 39449095684 scopus 로고    scopus 로고
    • Tutorial on photoacoustic microscopy and computed tomography
    • Jan./Feb.
    • L. V. Wang, "Tutorial on photoacoustic microscopy and computed tomography," IEEE J. Selected Topics Quantum Electron., vol. 14, no. 1, pp. 171-179, Jan./Feb. 2008.
    • (2008) IEEE J. Selected Topics Quantum Electron. , vol.14 , Issue.1 , pp. 171-179
    • Wang, L.V.1
  • 4
    • 33947692710 scopus 로고    scopus 로고
    • Explicit inversion formulae for the spherical mean radon transform
    • L. A. Kunyansky, "Explicit inversion formulae for the spherical mean radon transform," Inverse Problems, vol. 23, pp. 373-383, 2007.
    • (2007) Inverse Problems , vol.23 , pp. 373-383
    • Kunyansky, L.A.1
  • 5
    • 3042713885 scopus 로고    scopus 로고
    • Rakesh Determining a function from its mean values over a family of spheres
    • D. Finch, S. Patch, and Rakesh, "Determining a function from its mean values over a family of spheres," SIAM J. Math. Anal., vol. 35, pp. 1213-1240, 2004.
    • (2004) SIAM J. Math. Anal. , vol.35 , pp. 1213-1240
    • Finch, D.1    Patch, S.2
  • 6
    • 37649027576 scopus 로고    scopus 로고
    • Universal back-projection algorithm for pho-toacoustic computed tomography
    • Y. Xu and L. V. Wang, "Universal back-projection algorithm for pho-toacoustic computed tomography," Phys. Rev. E, vol. 71, 2005.
    • (2005) Phys. Rev. e , vol.71
    • Xu, Y.1    Wang, L.V.2
  • 7
    • 0036628476 scopus 로고    scopus 로고
    • Exact frequency-domain reconstruction for thermoacoustic tomography - I: Planar geometry
    • DOI 10.1109/TMI.2002.801172, PII 1011092002801172
    • Y. Xu, D. Feng, and L. V. Wang, "Exact frequency-domain reconstruction for thermoacoustic tomography: I. Planar geometry," IEEE Trans. Med. Imag., vol. 21, no. 7, pp. 823-828, Jul. 2002. (Pubitemid 35250495)
    • (2002) IEEE Transactions on Medical Imaging , vol.21 , Issue.7 , pp. 823-828
    • Xu, Y.1    Feng, D.2    Wang, L.V.3
  • 8
    • 17444373112 scopus 로고    scopus 로고
    • Half-time image reconstructionin thermoacoustic tomography
    • Feb.
    • M. A. Anastasio, J. Zhang, X. Pan, Y. Zou, G. Keng, and L. V. Wang, "Half-time image reconstructionin thermoacoustic tomography," IEEE Trans. Med. Imag., vol. 24, no. 2, pp. 199-210, Feb. 2005.
    • (2005) IEEE Trans. Med. Imag. , vol.24 , Issue.2 , pp. 199-210
    • Anastasio, M.A.1    Zhang, J.2    Pan, X.3    Zou, Y.4    Keng, G.5    Wang, L.V.6
  • 9
    • 58149105384 scopus 로고    scopus 로고
    • Three-dimensional photoacoustic imaging by sparse-array detection and iterative image reconstruction
    • P. Ephrat, L. Keenliside, A. Seabrook, F. S. Prato, and J. J. L. Carson, "Three-dimensional photoacoustic imaging by sparse-array detection and iterative image reconstruction," J. Biomed. Opt. vol. 13, no. 5, 2008.
    • (2008) J. Biomed. Opt. , vol.13 , Issue.5
    • Ephrat, P.1    Keenliside, L.2    Seabrook, A.3    Prato, F.S.4    Carson, J.J.L.5
  • 10
    • 0036789225 scopus 로고    scopus 로고
    • Iterative reconstruction algorithm for optoacoustic imaging
    • G. Paltauf, J. A. Viator, S. A. Prahl, and S. L. Jacques, "Iterative reconstruction algorithm for optoacoustic imaging," J. Acoust. Soc. Am. vol. 112, no. 4, pp. 1536-1544, 2002.
    • (2002) J. Acoust. Soc. Am. , vol.112 , Issue.4 , pp. 1536-1544
    • Paltauf, G.1    Viator, J.A.2    Prahl, S.A.3    Jacques, S.L.4
  • 11
    • 70350770986 scopus 로고    scopus 로고
    • Effects of different imaging models on least-squares image reconstruction accuracy in photoacoustic tomography
    • Nov.
    • J. Zhang, M. Anastasio, P. La Riviere, and L. Wang, "Effects of different imaging models on least-squares image reconstruction accuracy in photoacoustic tomography," IEEE Tran. Med. Imag., vol. 28, no. 11, pp. 1781-1790, Nov. 2009.
    • (2009) IEEE Tran. Med. Imag. , vol.28 , Issue.11 , pp. 1781-1790
    • Zhang, J.1    Anastasio, M.2    La Riviere, P.3    Wang, L.4
  • 12
    • 34547265203 scopus 로고    scopus 로고
    • Ring-based ultrasonic virtual point detector with applications to photoacoustic tomography
    • X. Yang, M.-L. Li, and L. V. Wang, "Ring-based ultrasonic virtual point detector with applications to photoacoustic tomography," Appl. Phys. Lett. vol. 90, no. 25, 2007.
    • (2007) Appl. Phys. Lett. , vol.90 , Issue.25
    • Yang, X.1    Li, M.-L.2    Wang, L.V.3
  • 13
    • 0019585077 scopus 로고
    • Review of transient field theory for a baffled planar piston
    • G. R. Harris, "Review of transient field theory for a baffled planar piston," J. Acoustical Soc. Am. vol. 70, no. 1, pp. 10-20, 1981.
    • (1981) J. Acoustical Soc. Am. , vol.70 , Issue.1 , pp. 10-20
    • Harris, G.R.1
  • 14
    • 66249126840 scopus 로고    scopus 로고
    • Development of laser optoa-coustic and ultrasonic imaging system for breast cancer utilizing handheld array probe
    • A. A. Oraevsky and L. V. Wang, Eds.
    • S. A. Ermilov, M. P. Fronheiser, H.-P. Brecht, R. Su, A. Conjusteau, K. Mehta, P. Otto, and A. A. Oraevsky, "Development of laser optoa-coustic and ultrasonic imaging system for breast cancer utilizing handheld array probe," in Proc. SPIE, A. A. Oraevsky and L. V. Wang, Eds., 2009, vol. 7177, no. 1, p. 717703.
    • (2009) Proc. SPIE , vol.7177 , Issue.1 , pp. 717703
    • Ermilov, S.A.1    Fronheiser, M.P.2    Brecht, H.-P.3    Su, R.4    Conjusteau, A.5    Mehta, K.6    Otto, P.7    Oraevsky, A.A.8
  • 15
    • 28844438544 scopus 로고    scopus 로고
    • Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction
    • M. Xu and L. V. Wang, "Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction," Phys. Rev. E, vol. 67, 2003.
    • (2003) Phys. Rev. e , vol.67
    • Xu, M.1    Wang, L.V.2
  • 16
    • 36749078796 scopus 로고    scopus 로고
    • Application of inverse source concepts to photoacoustic tomography
    • M. A. Anastasio, J. Zhang, D. Modgil, and P. La Riviere, "Application of inverse source concepts to photoacoustic tomography," Inverse Problems, vol. 23, pp. S21-S35, 2007.
    • (2007) Inverse Problems , vol.23
    • Anastasio, M.A.1    Zhang, J.2    Modgil, D.3    La Riviere, P.4
  • 17
    • 0032860847 scopus 로고    scopus 로고
    • Thermoacoustic computed tomography-Technical considerations
    • R. Kruger, D. Reinecke, and G. Kruger, "Thermoacoustic computed tomography-Technical considerations," Med. Phys., vol. 26, pp. 1832-1837, 1999.
    • (1999) Med. Phys. , vol.26 , pp. 1832-1837
    • Kruger, R.1    Reinecke, D.2    Kruger, G.3
  • 18
    • 77951542976 scopus 로고    scopus 로고
    • Effect of sensor directionality on photoacoustic imaging: A study using the K-Wave
    • B. T. Cox and B. E. TreebyA. A. Oraevsky and L. V. Wang, Effect of sensor directionality on photoacoustic imaging: A study using the K-Wave Toolbox SPIE, 2010, vol. 7564, no. 1.
    • (2010) Toolbox SPIE , vol.7564 , Issue.1
    • Cox, B.T.1    Treeby, B.E.2    Oraevsky, A.A.3    Wang, L.V.4
  • 19
    • 77951593059 scopus 로고    scopus 로고
    • Reconstruction of photoacoustic tomography with finite-aperture detectors: De-convolution of the spatial impulse response
    • M.-L. Li, C.-C. Cheng, A. A. Oraevsky, and L. V. Wang, "Reconstruction of photoacoustic tomography with finite-aperture detectors: De-convolution of the spatial impulse response," in Proc. SPIE, 2010, vol. 7564, no. 1, p. 75642S.
    • (2010) Proc. SPIE , vol.7564 , Issue.1
    • Li, M.-L.1    Cheng, C.-C.2    Oraevsky, A.A.3    Wang, L.V.4
  • 20
    • 33644891080 scopus 로고    scopus 로고
    • Improved in vivo photoacoustic microscopy based on a virtual-detector concept
    • M.-L. Li, H. F. Zhang, K. Maslov, G. Stoica, and L. V. Wang, "Improved in vivo photoacoustic microscopy based on a virtual-detector concept," Opt. Lett. vol. 31, no. 4, pp. 474-476, 2006.
    • (2006) Opt. Lett. , vol.31 , Issue.4 , pp. 474-476
    • Li, M.-L.1    Zhang, H.F.2    Maslov, K.3    Stoica, G.4    Wang, L.V.5
  • 21
    • 48349114728 scopus 로고    scopus 로고
    • High-numerical-aperture-based virtual point detectors for photoacoustic tomography
    • C. Li and L. V. Wang, "High-numerical-aperture-based virtual point detectors for photoacoustic tomography," Appl. Phys. Lett. vol. 93, no. 3, 2008.
    • (2008) Appl. Phys. Lett. , vol.93 , Issue.3
    • Li, C.1    Wang, L.V.2
  • 22
    • 6344282855 scopus 로고    scopus 로고
    • Thermoa-coustic computed tomography with large planar receivers
    • M. Haltmeier, O. Scherzer, P. Burgholzer, and G. Paltauf, "Thermoa-coustic computed tomography with large planar receivers," Inverse Problems vol. 20, no. 5, pp. 1663-1673, 2004.
    • (2004) Inverse Problems , vol.20 , Issue.5 , pp. 1663-1673
    • Haltmeier, M.1    Scherzer, O.2    Burgholzer, P.3    Paltauf, G.4
  • 23
    • 66549117497 scopus 로고    scopus 로고
    • Characterization of integrating ultrasound detectors for photoacoustic tomography
    • G. Paltauf, R. Nuster, and P. Burgholzer, "Characterization of integrating ultrasound detectors for photoacoustic tomography," J. Appl. Phys. vol. 105, no. 10, 2009.
    • (2009) J. Appl. Phys. , vol.105 , Issue.10
    • Paltauf, G.1    Nuster, R.2    Burgholzer, P.3
  • 24
    • 0038586601 scopus 로고    scopus 로고
    • Thermoacoustic computed tomography using a conventional linear transducer array
    • R. A. Kruger, J. William, L. Kiser, D. R. Reinecke, and G. A. Kruger, "Thermoacoustic computed tomography using a conventional linear transducer array," Med. Phys. vol. 30, no. 5, pp. 856-860, 2003.
    • (2003) Med. Phys. , vol.30 , Issue.5 , pp. 856-860
    • Kruger, R.A.1    William, J.2    Kiser, L.3    Reinecke, D.R.4    Kruger, G.A.5
  • 25
    • 3943068419 scopus 로고    scopus 로고
    • Photoacoustic and ultrasonic coimage with a linear transducer array
    • Y. Zeng, D. Xing, Y. Wang, B. Yin, and Q. Chen, "Photoacoustic and ultrasonic coimage with a linear transducer array," Opt. Lett., vol. 29, pp. 1760-1762, 2004.
    • (2004) Opt. Lett. , vol.29 , pp. 1760-1762
    • Zeng, Y.1    Xing, D.2    Wang, Y.3    Yin, B.4    Chen, Q.5
  • 26
    • 42249105556 scopus 로고    scopus 로고
    • Improving limited-view reconstructionin photoacoustic tomography by incorporating a priori boundary information
    • A. A. Oraevsky and L. V. Wang, Eds.
    • M. A. Anastasio, K. Wang, J. Zhang, G. A. Kruger, D. Reinecke, and R. A.Kruger, "Improving limited-view reconstructionin photoacoustic tomography by incorporating a priori boundary information," in Proc. SPIE, A. A. Oraevsky and L. V. Wang, Eds., 2008, vol. 6856, no. 1, p. 68561B.
    • (2008) Proc. SPIE , vol.6856 , Issue.1
    • Anastasio, M.A.1    Wang, K.2    Zhang, J.3    Kruger, G.A.4    Reinecke, D.5    Kruger, R.A.6
  • 28
    • 33646434247 scopus 로고    scopus 로고
    • Photoacoustic imaging in biomedicine
    • M. Xu and L. V. Wang, "Photoacoustic imaging in biomedicine," Rev. Sci. Instrum., vol. 77, 2006.
    • (2006) Rev. Sci. Instrum. , vol.77
    • Xu, M.1    Wang, L.V.2
  • 31
    • 41149180636 scopus 로고    scopus 로고
    • Mathematics of thermoacoustic tomography
    • P. Kuchment and L. Kunyansky, "Mathematics of thermoacoustic tomography," Eur. J. Appl. Math., vol. 19, no. 02, pp. 191-224, 2008.
    • (2008) Eur. J. Appl. Math. , vol.19 , Issue.2 , pp. 191-224
    • Kuchment, P.1    Kunyansky, L.2
  • 32
    • 0015592271 scopus 로고
    • High-speed method for computing the exact solution for the pressure variations in the nearfield of a baffled piston
    • J. C. Lockwood and J. G. Willette, "High-speed method for computing the exact solution for the pressure variations in the nearfield of a baffled piston," J. Acoust. Soc. Am. vol. 53, no. 3, pp. 735-741, 1973.
    • (1973) J. Acoust. Soc. Am. , vol.53 , Issue.3 , pp. 735-741
    • Lockwood, J.C.1    Willette, J.G.2
  • 33
    • 84955033020 scopus 로고
    • Transient radiation from pistons in an infinite planar baffle
    • P. R. Stepanishen, "Transient radiation from pistons in an infinite planar baffle," J. Acoust. Soc. Am. vol. 49, no. 5B, pp. 1629-1638, 1971.
    • (1971) J. Acoust. Soc. Am. , vol.49 , Issue.5 B , pp. 1629-1638
    • Stepanishen, P.R.1
  • 34
    • 0036401568 scopus 로고    scopus 로고
    • Detection of optoacoustic transients with a rectangular transducer of finite dimensions
    • V. G. Andreev, A. A. Karabutov, A. E. Ponomaryov, and A. A. Oraevsky, A. A. Oraevsky, Ed., Detection of optoacoustic transients with a rectangular transducer of finite dimensions Proc. SPIE, 2002, vol. 4618, no. 1, pp. 153-162.
    • (2002) Proc. SPIE , vol.4618 , Issue.1 , pp. 153-162
    • Andreev, V.G.1    Karabutov, A.A.2    Ponomaryov, A.E.3    Oraevsky, A.A.4    Oraevsky, A.A.5
  • 35
    • 0038137178 scopus 로고    scopus 로고
    • Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response
    • K. P. Kostli and P. C. Beard, "Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response," Appl. Opt., vol. 42, pp. 1899-1908, 2003.
    • (2003) Appl. Opt. , vol.42 , pp. 1899-1908
    • Kostli, K.P.1    Beard, P.C.2
  • 36
    • 0026544838 scopus 로고
    • Alternatives to voxels for image representation in iterative reconstruction algorithms
    • R. M. Lewitt, "Alternatives to voxels for image representation in iterative reconstruction algorithms," Phys. Med. Biol., vol. 37, pp. 705-, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 705
    • Lewitt, R.M.1
  • 37
    • 0000831287 scopus 로고
    • Properties of photoacoustic waves in one, two, and three dimensions
    • G. Diebold and T. Sun, "Properties of photoacoustic waves in one, two, and three dimensions," Acustica, vol. 80, no. 4, pp. 339-351, 1994.
    • (1994) Acustica , vol.80 , Issue.4 , pp. 339-351
    • Diebold, G.1    Sun, T.2
  • 38
    • 1842550440 scopus 로고
    • Photoacoustic monopole radiation in one, two, and three dimensions
    • G. Diebold, T. Sun, and M. Khan, "Photoacoustic monopole radiation in one, two, and three dimensions," Phys. Rev. Lett., vol. 67, no. 24, pp. 3384-3387, 1991.
    • (1991) Phys. Rev. Lett. , vol.67 , Issue.24 , pp. 3384-3387
    • Diebold, G.1    Sun, T.2    Khan, M.3
  • 39
    • 70349662097 scopus 로고    scopus 로고
    • Measurement of the spectral directivity of optoa-coustic and ultrasonic transducers with a laser ultrasonic source
    • Sep.
    • A. Conjusteau, S. A. Ermilov, R. Su, H.-P. Brecht, M. P. Fronheiser, and A. A. Oraevsky, "Measurement of the spectral directivity of optoa-coustic and ultrasonic transducers with a laser ultrasonic source," Rev. Sci. Instrum., vol. 80, no. 9, Sep. 2009.
    • (2009) Rev. Sci. Instrum. , vol.80 , Issue.9
    • Conjusteau, A.1    Ermilov, S.A.2    Su, R.3    Brecht, H.-P.4    Fronheiser, M.P.5    Oraevsky, A.A.6
  • 40
    • 0030241912 scopus 로고    scopus 로고
    • Spatial resolution properties of pe-nalized-likelihood image reconstruction methods: Space-invariant tomographs
    • Sep.
    • J. A. Fessler and W. L. Rogers, "Spatial resolution properties of pe-nalized-likelihood image reconstruction methods: Space-invariant tomographs," IEEE Trans. Image Process., vol. 5, no. 9, pp. 1346-1358, Sep. 1996.
    • (1996) IEEE Trans. Image Process. , vol.5 , Issue.9 , pp. 1346-1358
    • Fessler, J.A.1    Rogers, W.L.2
  • 42
    • 79551580187 scopus 로고    scopus 로고
    • Cumulative Gaussian curve fitter for boundary parameterization
    • Aug.
    • D. C. Wang, R. J. Tamburo, and G. D. Stetten, "Cumulative Gaussian curve fitter for boundary parameterization," in Insight J., Aug. 2005.
    • (2005) Insight J.
    • Wang, D.C.1    Tamburo, R.J.2    Stetten, G.D.3
  • 44
    • 15044352366 scopus 로고    scopus 로고
    • Osirix: An open-source software for navigating in multidimensional dicom images
    • A. Rosset, L. Spadola, and O. Ratib, "Osirix: An open-source software for navigating in multidimensional dicom images," J. Digital Imag., vol. 17, no. 3, pp. 205-216, 2004.
    • (2004) J. Digital Imag. , vol.17 , Issue.3 , pp. 205-216
    • Rosset, A.1    Spadola, L.2    Ratib, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.