메뉴 건너뛰기




Volumn 225, Issue 2, 2011, Pages 194-198

The fatigue life of contoured cobalt chrome posterior spinal fusion rods

Author keywords

cobalt chrome; fatigue; French Bender; rod contouring; spinal fixation

Indexed keywords

ARTHRODESIS; CURVED ROD; FATIGUE; FATIGUE LIFE; FRENCH BENDER; HIGH LOAD; INTRA-OPERATIVE; LOAD RATIO; MAXIMUM LOAD; MAXIMUM LOADING; NOTCH SENSITIVITY; PEDICLE SCREWS; POSTERIOR ARTHRODESIS; POSTERIOR SPINAL FUSIONS; ROD CONTOURING; SPINAL FIXATION; STATIC STRENGTH; TOTAL CURVATURE; VERTEBRECTOMY; COBALT CHROMES; COMPRESSION BENDING; CONTOURING;

EID: 79551531384     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM763     Document Type: Article
Times cited : (69)

References (16)
  • 1
    • 33845493696 scopus 로고    scopus 로고
    • Radiological risk factors of pseudoarthrosis and/or instrument breakage after PLF with the pedicle screw system in isthmic spondylolisthesis
    • Suda, K., Ito, M., Abumi, K., Haba, H., Taneichi, H., and Kaneda, K. Radiological risk factors of pseudoarthrosis and/or instrument breakage after PLF with the pedicle screw system in isthmic spondylolisthesis. J. Spinal Disord. Tech., 2006, 19(8), 541-546.
    • (2006) J. Spinal Disord. Tech. , vol.19 , Issue.8 , pp. 541-546
    • Suda, K.1    Ito, M.2    Abumi, K.3    Haba, H.4    Taneichi, H.5    Kaneda, K.6
  • 2
    • 0038353715 scopus 로고    scopus 로고
    • A 10-year follow-up evaluation of lumbar spine fusion with pedicle screw fixation
    • Glaser, J., Stanley, M., Sayre, H., Woody, J., Found, E., and Spratt, K. A 10-year follow-up evaluation of lumbar spine fusion with pedicle screw fixation. Spine, 2003, 28(13), 1390-1395.
    • (2003) Spine , vol.28 , Issue.13 , pp. 1390-1395
    • Glaser, J.1    Stanley, M.2    Sayre, H.3    Woody, J.4    Found, E.5    Spratt, K.6
  • 3
    • 35448999983 scopus 로고    scopus 로고
    • Comparison between posterior lumbar fusion with pedicle screws and posterior lumbar interbody fusion with pedicle screws in adult spondylolisthesis
    • Dantas, F. L., Prandini, M. N., and Ferreira, M. A. Comparison between posterior lumbar fusion with pedicle screws and posterior lumbar interbody fusion with pedicle screws in adult spondylolisthesis. Arq. Neuropsiquiat., 2007, 65(3B), 764-770.
    • (2007) Arq. Neuropsiquiat. , vol.65 , Issue.3 B , pp. 764-770
    • Dantas, F.L.1    Prandini, M.N.2    Ferreira, M.A.3
  • 4
    • 0035419317 scopus 로고    scopus 로고
    • Notch sensitivity of titanium alloy commercially pure titanium, and stainless steel spinal implants
    • Dick, J. C. and Bourgeault, C. A. Notch sensitivity of titanium alloy, commercially pure titanium, and stainless steel spinal implants. Spine, 2001, 26(15), 1668-1672.
    • (2001) Spine , vol.26 , Issue.15 , pp. 1668-1672
    • Dick, J.C.1    Bourgeault, C.A.2
  • 5
    • 33745725997 scopus 로고    scopus 로고
    • The effects of rod contouring on spinal construct fatigue strength
    • Lindsey, C., Deviren, V., Xu, Z., Yeh, R. F., and Puttlitz, C. M. The effects of rod contouring on spinal construct fatigue strength. Spine, 2006, 31(15), 1680-1687.
    • (2006) Spine , vol.31 , Issue.15 , pp. 1680-1687
    • Lindsey, C.1    Deviren, V.2    Xu, Z.3    Yeh, R.F.4    Puttlitz, C.M.5
  • 7
    • 73849155435 scopus 로고
    • Vitallium mold arthroplasty of the hip in rheumatoid arthritis
    • Solomon, L. and Aufranc, O. E. Vitallium mold arthroplasty of the hip in rheumatoid arthritis. Arthritis Rheum., 1962, 5, 37-54.
    • (1962) Arthritis Rheum. , vol.5 , pp. 37-54
    • Solomon, L.1    Aufranc, O.E.2
  • 8
    • 0015156744 scopus 로고
    • Vitallium mold arthroplasty and femoral prosthetic replacement in the surgical management of rheumatoid arthritis in the hip
    • Bryan, R. S. and Bickel, W. H. Vitallium mold arthroplasty and femoral prosthetic replacement in the surgical management of rheumatoid arthritis in the hip. Orthop. Clin. North Am., 1971, 2(3), 687-695.
    • (1971) Orthop. Clin. North Am. , vol.2 , Issue.3 , pp. 687-695
    • Bryan, R.S.1    Bickel, W.H.2
  • 9
    • 34548811025 scopus 로고    scopus 로고
    • Vitallium cup arthroplasty: Case report of a 57-year follow-up
    • Anderson, J. T. and Gluck, J. L. Vitallium cup arthroplasty: case report of a 57-year follow-up. Am. J. Orthop., 2007, 36(4), E50-E52.
    • (2007) Am. J. Orthop. , vol.36 , Issue.4
    • Anderson, J.T.1    Gluck, J.L.2
  • 10
    • 0029996966 scopus 로고    scopus 로고
    • Smith-Petersen vitallium mould arthroplasty: A 45-year follow-up
    • Mahalingam, K. and Reidy, D. Smith-Petersen vitallium mould arthroplasty: a 45-year follow-up. J. Bone Joint Surg. Br., 1996, 78(3), 496-497.
    • (1996) J. Bone Joint Surg. Br. , vol.78 , Issue.3 , pp. 496-497
    • Mahalingam, K.1    Reidy, D.2
  • 11
    • 76549174224 scopus 로고
    • A new long-stem intramedullary vitallium hip prosthesis; preliminary report
    • Matchett, F. A new long-stem intramedullary vitallium hip prosthesis; preliminary report. J. Bone Joint Surg. Am., 1965, 47, 43-64.
    • (1965) J. Bone Joint Surg. Am. , vol.47 , pp. 43-64
    • Matchett, F.1
  • 12
    • 77049129205 scopus 로고
    • Vitallium cup arthroplasty for selected hip disabilities
    • Matchett, F. Vitallium cup arthroplasty for selected hip disabilities. Rocky Mt. Med. J., 1952, 49(12), 1045-1049.
    • (1952) Rocky Mt. Med. J. , vol.49 , Issue.12 , pp. 1045-1049
    • Matchett, F.1
  • 13
    • 0031060065 scopus 로고    scopus 로고
    • Loads on an internal spinal fixation device during walking
    • Rohlmann, A., Bergmann, G., and Graichen, F. Loads on an internal spinal fixation device during walking. J. Biomech., 1997, 30(1), 41-47.
    • (1997) J. Biomech. , vol.30 , Issue.1 , pp. 41-47
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3
  • 14
    • 0035918853 scopus 로고    scopus 로고
    • Comparison of intradiscal pressures and spinal fixator loads for different body positions and exercises
    • Rohlmann, A., Claes, L. E., Bergmannt, G., Graichen, F., Neef, P., and Wilke, H. J. Comparison of intradiscal pressures and spinal fixator loads for different body positions and exercises. Ergonomics, 2001, 44(8), 781-794.
    • (2001) Ergonomics , vol.44 , Issue.8 , pp. 781-794
    • Rohlmann, A.1    Claes, L.E.2    Bergmannt, G.3    Graichen, F.4    Neef, P.5    Wilke, H.J.6
  • 15
    • 0020617104 scopus 로고
    • Corrosion of titanium/cobalt-chromium alloy couples
    • Kummer, F. J. and Rose, R. M. Corrosion of titanium/cobalt-chromium alloy couples. J. Bone Joint Surg. Am., 1983, 65(8), 1125-1126.
    • (1983) J. Bone Joint Surg. Am. , vol.65 , Issue.8 , pp. 1125-1126
    • Kummer, F.J.1    Rose, R.M.2
  • 16
    • 24744452628 scopus 로고    scopus 로고
    • Microvascular response of striated muscle to common arthroplasty-alloys: A comparative in vivo study with CoCrMo Ti-6Al-4V, and Ti-6Al-7Nb
    • Kraft, C. N., Burian, B., Diedrich, O., Gessmann, J., Wimmer, M. A., and Pennekamp, P. H. Microvascular response of striated muscle to common arthroplasty-alloys: a comparative in vivo study with CoCrMo, Ti-6Al-4V, and Ti-6Al-7Nb. J. Biomed. Mater. Res. A, 2005, 75(1), 31-40.
    • (2005) J. Biomed. Mater. Res. A , vol.75 , Issue.1 , pp. 31-40
    • Kraft, C.N.1    Burian, B.2    Diedrich, O.3    Gessmann, J.4    Wimmer, M.A.5    Pennekamp, P.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.