메뉴 건너뛰기




Volumn 21, Issue 1, 2011, Pages 1110-1127

Characterization of aging transformer oil-pressboard insulation using some modern diagnostic techniques

Author keywords

aging by products; dielectric spectroscopy; infrared spectroscopy; recovery voltage measurement; spectrophotometry; turbidity

Indexed keywords

AGING BY-PRODUCTS; AGING OF TRANSFORMER; CELLULOSIC MATERIAL; CHEMICAL DIAGNOSTICS; CHEMICAL TECHNIQUES; CHEMICAL TESTS; CONTROLLED LABORATORIES; DECAY PRODUCTS; DIAGNOSTIC TECHNIQUES; DIAGNOSTIC TOOLS; ELECTRICAL DIAGNOSTICS; FOURIER TRANSFORM INFRARED; FREQUENCY DOMAINS; FTIR; INSULATION CONDITIONS; INSULATION DEGRADATION; OIL INSULATIONS; OIL PAPER INSULATION; POLARISATION/DEPOLARISATION CURRENT; PRACTICING ENGINEERS; PRESSBOARD INSULATION; RECOVERY VOLTAGE MEASUREMENT; RECOVERY VOLTAGE MEASUREMENTS; SOLID SUSPENSIONS; SPECTROSCOPY MEASUREMENTS; TRANSFORMER OIL; UTILITY PROFESSIONALS;

EID: 79551505079     PISSN: 1430144X     EISSN: 15463109     Source Type: Journal    
DOI: 10.1002/etep.499     Document Type: Article
Times cited : (81)

References (53)
  • 2
    • 0003190002 scopus 로고
    • Lifetime evaluation of transformers
    • IEEE Working Group 09 (Thermal aspects of transformers) of CIGRE Study Committee 12
    • IEEE Working Group 09 (Thermal aspects of transformers) of CIGRE Study Committee 12. Lifetime evaluation of transformers. Electra 1993; 150: 39-51.
    • (1993) Electra , vol.150 , pp. 39-51
  • 6
    • 42149108015 scopus 로고    scopus 로고
    • Understanding the impacts of moisture and thermal aging on transformer's insulation by dielectric response and molecular weight measurements
    • Saha TK, Purkait P,. Understanding the impacts of moisture and thermal aging on transformer's insulation by dielectric response and molecular weight measurements. IEEE Transactions on Dielectrics and Electrical Insulation 2008; 15 (2): 568-582.
    • (2008) IEEE Transactions on Dielectrics and Electrical Insulation , vol.15 , Issue.2 , pp. 568-582
    • Saha, T.K.1    Purkait, P.2
  • 9
    • 55849097464 scopus 로고    scopus 로고
    • Chemistry behind the life of a transformer
    • Shanghi R,. Chemistry behind the life of a transformer. Resonance 2003; 8 (6): 17-23.
    • (2003) Resonance , vol.8 , Issue.6 , pp. 17-23
    • Shanghi, R.1
  • 11
    • 0036646352 scopus 로고    scopus 로고
    • Suspended particles in the liquid insulation of aging power transformers
    • Ferguson R, Lobeiras A, Sabau J,. Suspended particles in the liquid insulation of aging power transformers. IEEE Electrical Insulation Magazine 2002; 18 (4): 17-23.
    • (2002) IEEE Electrical Insulation Magazine , vol.18 , Issue.4 , pp. 17-23
    • Ferguson, R.1    Lobeiras, A.2    Sabau, J.3
  • 14
    • 0030145819 scopus 로고    scopus 로고
    • Measuring and understanding the ageing of kraft insulating paper in power transformers
    • Ali M, Eley C, Emsley AM, Heywood R, Xaio X,. Measuring and understanding the ageing of kraft insulating paper in power transformers. IEEE Electrical Insulation Magazine 1996; 12 (3): 28-34.
    • (1996) IEEE Electrical Insulation Magazine , vol.12 , Issue.3 , pp. 28-34
    • Ali, M.1    Eley, C.2    Emsley, A.M.3    Heywood, R.4    Xaio, X.5
  • 15
    • 0034313980 scopus 로고    scopus 로고
    • Degradation of cellulosic insulation in power transformers. Part 4: Effects of ageing on the tensile strength of paper
    • Emsley AM, Heywood RJ, Ali M, Xiao X,. Degradation of cellulosic insulation in power transformers. Part 4: Effects of ageing on the tensile strength of paper. IEE Proceedings Science, Measurement and Technology 2000; 147 (6): 285-290.
    • (2000) IEE Proceedings Science, Measurement and Technology , vol.147 , Issue.6 , pp. 285-290
    • Emsley, A.M.1    Heywood, R.J.2    Ali, M.3    Xiao, X.4
  • 17
    • 0002416206 scopus 로고    scopus 로고
    • Furanic compounds analysis: A tool for predictive maintenance of oil-filled electrical equipment
    • Pablo ADe, Pahlavanpour B,. Furanic compounds analysis: a tool for predictive maintenance of oil-filled electrical equipment. Electra 1997; 175: 9-32.
    • (1997) Electra , vol.175 , pp. 9-32
    • Pablo, A.1    Pahlavanpour, B.2
  • 18
    • 39749085888 scopus 로고    scopus 로고
    • On the degradation evolution equations of cellulose
    • Ding HZ, Wang ZD,. On the degradation evolution equations of cellulose. Cellulose 2008; 15: 205-224.
    • (2008) Cellulose , vol.15 , pp. 205-224
    • Ding, H.Z.1    Wang, Z.D.2
  • 19
    • 17644395307 scopus 로고    scopus 로고
    • Aging of cellulose at transformer service temperatures. Part 1: Influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases, and furanic compounds in oil
    • Höhlein I, Kachler AJ,. Aging of cellulose at transformer service temperatures. Part 1: Influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases, and furanic compounds in oil. IEEE Electrical Insulation Magazine 2005; 21 (2): 15-21.
    • (2005) IEEE Electrical Insulation Magazine , vol.21 , Issue.2 , pp. 15-21
    • Höhlein, I.1    Kachler, A.J.2
  • 23
    • 77952030632 scopus 로고    scopus 로고
    • A comparative study of thermal aging of transformer insulation paper impregnated in natural ester and in mineral oil
    • Liao R, Liang S, Sun C, Yang L, Sun H,. A comparative study of thermal aging of transformer insulation paper impregnated in natural ester and in mineral oil. European Transactions on Electrical Power 2010; 20 (4): 518-533.
    • (2010) European Transactions on Electrical Power , vol.20 , Issue.4 , pp. 518-533
    • Liao, R.1    Liang, S.2    Sun, C.3    Yang, L.4    Sun, H.5
  • 26
    • 0242720703 scopus 로고    scopus 로고
    • Dielectric spectroscopy in time and frequency domain for HV power equipment. Part I: Theoretical considerations
    • Zaengl WS,. Dielectric spectroscopy in time and frequency domain for HV power equipment. Part I: theoretical considerations. IEEE Electrical Insulation Magazine 2003; 19 (5): 5-19.
    • (2003) IEEE Electrical Insulation Magazine , vol.19 , Issue.5 , pp. 5-19
    • Zaengl, W.S.1
  • 27
    • 1242330865 scopus 로고    scopus 로고
    • Application of dielectric spectroscopy in time and frequency domain for HV power equipment
    • Zaengl WS,. Application of dielectric spectroscopy in time and frequency domain for HV power equipment. IEEE Electrical Insulation Magazine 2003; 19 (6): 9-22.
    • (2003) IEEE Electrical Insulation Magazine , vol.19 , Issue.6 , pp. 9-22
    • Zaengl, W.S.1
  • 31
    • 27144558772 scopus 로고    scopus 로고
    • Correlation between time and frequency domain polarization measurements for transformer moisture assessment
    • September 26-29th 2004, Brisbane, Australia
    • Saha TK, Middleton R, Thomas A,. Correlation between time and frequency domain polarization measurements for transformer moisture assessment. Australasian Universities Power Engineering Conference (AUPEC), September 26-29th 2004, Brisbane, Australia.
    • Australasian Universities Power Engineering Conference (AUPEC)
    • Saha, T.K.1    Middleton, R.2    Thomas, A.3
  • 32
    • 0344465271 scopus 로고    scopus 로고
    • Review of modern diagnostic techniques for assessing insulation condition in aged transformers
    • Saha TK,. Review of modern diagnostic techniques for assessing insulation condition in aged transformers. IEEE Transactions on Dielectrics and Electrical Insulation 2003; 10, 903-917.
    • (2003) IEEE Transactions on Dielectrics and Electrical Insulation , vol.10 , pp. 903-917
    • Saha, T.K.1
  • 34
    • 0141883203 scopus 로고    scopus 로고
    • Review of time-domain polarization measurements for assessing insulation condition in aged transformers
    • Saha TK,. Review of time-domain polarization measurements for assessing insulation condition in aged transformers. IEEE Transactions on Power Delivery 2003; 18: 1293-1301.
    • (2003) IEEE Transactions on Power Delivery , vol.18 , pp. 1293-1301
    • Saha, T.K.1
  • 36
    • 79953655525 scopus 로고    scopus 로고
    • The latest on-site non-destructive technique for insulation analysis of electrical power apparatus
    • 8-10th November 2004, Sacramento, USA
    • Supatra AB,. The latest on-site non-destructive technique for insulation analysis of electrical power apparatus. Weidmann-ACTI Annual Technical Conference, 8-10th November 2004, Sacramento, USA.
    • Weidmann-ACTI Annual Technical Conference
    • Supatra, A.B.1
  • 37
    • 0036076082 scopus 로고    scopus 로고
    • Insulation diagnostics on power transformers using the polarization and depolarization current analysis
    • USA
    • Leibfried T, Kachler AJ,. Insulation diagnostics on power transformers using the polarization and depolarization current analysis. IEEE International Symposium Electrical Insulation, USA, 2002; 170-173.
    • (2002) IEEE International Symposium Electrical Insulation , pp. 170-173
    • Leibfried, T.1    Kachler, A.J.2
  • 38
    • 63049103447 scopus 로고    scopus 로고
    • On the usability of dielectric spectroscopy techniques as quality control tool
    • BouaÏcha A, Fofana I, Farzaneh M, et al,. On the usability of dielectric spectroscopy techniques as quality control tool. IEEE Electrical Insulation Magazine 2009; 25 (1): 6-14.
    • (2009) IEEE Electrical Insulation Magazine , vol.25 , Issue.1 , pp. 6-14
    • Bouaïcha, A.1    Fofana, I.2    Farzaneh, M.3
  • 43
    • 0023292028 scopus 로고
    • Influence of oxidation on the electrical properties of inhibited naphthenic and paraffinic transformer oils
    • Lamarre C, Crine JP, Duval M,. Influence of oxidation on the electrical properties of inhibited naphthenic and paraffinic transformer oils. IEEE Transactions on Electrical Insulation 1987; 22 (1): 57-62.
    • (1987) IEEE Transactions on Electrical Insulation , vol.22 , Issue.1 , pp. 57-62
    • Lamarre, C.1    Crine, J.P.2    Duval, M.3
  • 49
    • 0035838482 scopus 로고    scopus 로고
    • Detection of trace levels of water in oil by photoacostic spectroscopy
    • Foster NS, Amonette JE, Autrey T, Ho JT,. Detection of trace levels of water in oil by photoacostic spectroscopy. Sensors and Actuators B 2001; 77 (3): 620-624.
    • (2001) Sensors and Actuators B , vol.77 , Issue.3 , pp. 620-624
    • Foster, N.S.1    Amonette, J.E.2    Autrey, T.3    Ho, J.T.4
  • 51
    • 33947517131 scopus 로고    scopus 로고
    • An automated FTIR method for the routine quantitative determination of moisture in lubricants
    • Van de Voort FR, Cocciardia R, Sedman J, Juneau S,. An automated FTIR method for the routine quantitative determination of moisture in lubricants. Talanta 2007; 72 (1): 289-295.
    • (2007) Talanta , vol.72 , Issue.1 , pp. 289-295
    • Van De Voort, F.R.1    Cocciardia, R.2    Sedman, J.3    Juneau, S.4
  • 52
    • 79551473871 scopus 로고    scopus 로고
    • Assessment of insulation in aged power transformers and the correlation between the electrical and chemical properties
    • 18-21th October 1992, Victoria, BC, Canada
    • Darveniza M, Saha TK, Hill DJT, Le TT,. Assessment of insulation in aged power transformers and the correlation between the electrical and chemical properties. Annual Report IEEE Conference on Electrical Insulation Dielectric Phenomena, 18-21th October 1992, Victoria, BC, Canada; 671-678.
    • Annual Report IEEE Conference on Electrical Insulation Dielectric Phenomena , pp. 671-678
    • Darveniza, M.1    Saha, T.K.2    Hill, D.J.T.3    Le, T.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.