-
2
-
-
34748884291
-
North East Italian Prospective Hospital Renal Outcome Survey on Acute Kidney Injury (NEiPHROSAKI): Targeting the problem with the RIFLE Criteria
-
North East Italian Prospective Hospital Renal Outcome Survey on Acute Kidney Injury (NEiPHROS-AKI) Investigators
-
Cruz DN, Bolgan I, Perazella MA et al. North East Italian Prospective Hospital Renal Outcome Survey on Acute Kidney Injury (NEiPHROS-AKI) Investigators. North East Italian Prospective Hospital Renal Outcome Survey on Acute Kidney Injury (NEiPHROSAKI): targeting the problem with the RIFLE Criteria. Clin J Am Soc Nephrol 2007; 2: 418-425
-
(2007)
Clin J Am Soc Nephrol
, vol.2
, pp. 418-425
-
-
Cruz, D.N.1
Bolgan, I.2
Perazella, M.A.3
-
3
-
-
65549092898
-
Delivered dose of renal replacement therapy and mortality in critically ill patients with acute kidney injury
-
Vesconi S, Cruz DN, Fumagalli R et al. Delivered dose of renal replacement therapy and mortality in critically ill patients with acute kidney injury. Crit Care 2009; 13: R57
-
(2009)
Crit Care
, vol.13
-
-
Vesconi, S.1
Cruz, D.N.2
Fumagalli, R.3
-
4
-
-
23844521731
-
Acute renal failure in critically ill patients: A multinational, multicenter study
-
Beginning and Ending Supportive Therapy for the Kidney (BEST Kidney) Investigators
-
Uchino S, Kellum JA, Bellomo R et al. Beginning and Ending Supportive Therapy for the Kidney (BEST Kidney) Investigators. Acute renal failure in critically ill patients: a multinational, multicenter study. JAMA 2005; 294: 813-818
-
(2005)
JAMA
, vol.294
, pp. 813-818
-
-
Uchino, S.1
Kellum, J.A.2
Bellomo, R.3
-
5
-
-
0031950875
-
Continuous venovenous high-flux dialysis in multiorgan failure: A 5-year single-center experience
-
Jones CH, Richardson D, Goutcher E et al. Continuous venovenous high-flux dialysis in multiorgan failure: a 5-year single-center experience. Am J Kidney Dis 1998; 31: 227-233
-
(1998)
Am J Kidney Dis
, vol.31
, pp. 227-233
-
-
Jones, C.H.1
Richardson, D.2
Goutcher, E.3
-
6
-
-
0027438348
-
A comparison of conventional dialytic therapy and acute continuous hemodiafiltration in the management of acute renal failure in the critically ill
-
Bellomo R, Mansfield D, Rumble S et al. A comparison of conventional dialytic therapy and acute continuous hemodiafiltration in the management of acute renal failure in the critically ill. Ren Fail 1993; 15: 595-602 (Pubitemid 23358557)
-
(1993)
Renal Failure
, vol.15
, Issue.5
, pp. 595-602
-
-
Bellomo, R.1
Mansfield, D.2
Rumble, S.3
Shapiro, J.4
Parkin, G.5
Boyce, N.6
-
7
-
-
33746263991
-
Jugular vein catheter placement: Histologic features and development of catheter-related (fibrin) sheaths in a swine model
-
Forauer AR, Theoharis CG, Dasika NL. Jugular vein catheter placement: histologic features and development of catheter-related (fibrin) sheaths in a swine model. Radiology 2006; 240: 427-434
-
(2006)
Radiology
, vol.240
, pp. 427-434
-
-
Forauer, A.R.1
Theoharis, C.G.2
Dasika, N.L.3
-
8
-
-
0033774632
-
Hemodialysis catheterassociated fibrin sheaths: Treatment with a low-dose rt-PA infusion
-
Savader SJ, Haikal LC, Ehrman KO et al. Hemodialysis catheterassociated fibrin sheaths: treatment with a low-dose rt-PA infusion. J Vasc Interv Radiol 2000; 11: 1131-1136
-
(2000)
J Vasc Interv Radiol
, vol.11
, pp. 1131-1136
-
-
Savader, S.J.1
Haikal, L.C.2
Ehrman, K.O.3
-
9
-
-
38449120878
-
Catheter patency and function after catheter sheath disruption: A pilot study
-
Oliver MJ, Mendelssohn DC, Quinn RR et al. Catheter patency and function after catheter sheath disruption: a pilot study. Clin J Am Soc Nephrol 2007; 2: 1201-1206
-
(2007)
Clin J Am Soc Nephrol
, vol.2
, pp. 1201-1206
-
-
Oliver, M.J.1
Mendelssohn, D.C.2
Quinn, R.R.3
-
10
-
-
0028467860
-
Surface modifying additives for improved device-blood compatibility
-
Tsai CC, Deppisch R, Forrestal LJ et al. Surface modifying additives for improved device-blood compatibility. ASAIO J 1994; 40: M619-M624
-
(1994)
ASAIO J
, vol.40
-
-
Tsai, C.C.1
Deppisch, R.2
Forrestal, L.J.3
-
11
-
-
0003164152
-
Visualization and measurement of microdomains in polyamide dialysis membranes: Optimized size facilitates performance and bioincompatibility
-
Göhl H, Bell CM, Buck R et al. Visualization and measurement of microdomains in polyamide dialysis membranes: optimized size facilitates performance and bioincompatibility. Blood Purif 1992; 10: 86-92
-
(1992)
Blood Purif
, vol.10
, pp. 86-92
-
-
Göhl, H.1
Bell, C.M.2
Buck, R.3
-
12
-
-
0031749146
-
Microdomain structure of polymeric surfaces: Potential for improving blood treatment procedures
-
Deppisch R, Göhl H, Smeby L. Microdomain structure of polymeric surfaces: potential for improving blood treatment procedures. Nephrol Dial Transplant 1998; 13: 1354-1359
-
(1998)
Nephrol Dial Transplant
, vol.13
, pp. 1354-1359
-
-
Deppisch, R.1
Göhl, H.2
Smeby, L.3
-
13
-
-
0242426517
-
Prolonged catheter survival in intermittent hemodialysis using a less thrombogenic micropatterned polymer modification
-
Baumann M, Witzke O, Dietrich R et al. Prolonged catheter survival in intermittent hemodialysis using a less thrombogenic micropatterned polymer modification. ASAIO J 2003; 49: 708-712
-
(2003)
ASAIO J
, vol.49
, pp. 708-712
-
-
Baumann, M.1
Witzke, O.2
Dietrich, R.3
-
14
-
-
10244236377
-
Acute renal failure-definition, outcome measures, animalmodels, fluid therapy and information technology needs: The Second International Consensus Conference of the Acute Dialysis Quality Initiative (ADQI) Group
-
Bellomo R, Ronco C, Kellum JA et al. Acute renal failure-definition, outcome measures, animalmodels, fluid therapy and information technology needs: the Second International Consensus Conference of the Acute Dialysis Quality Initiative (ADQI) Group. Crit Care 2004; 8: R204-R212
-
(2004)
Crit Care
, vol.8
-
-
Bellomo, R.1
Ronco, C.2
Kellum, J.A.3
-
15
-
-
44349103698
-
Femoral vs jugular venous catheterization and risk of nosocomial events in adults requiring acute renal replacement therapy: A randomized controlled trial
-
Parienti JJ, Thirion M, Megarbane B et al. Femoral vs jugular venous catheterization and risk of nosocomial events in adults requiring acute renal replacement therapy: a randomized controlled trial. J Am Med Assoc 2008; 299: 2413-2422
-
(2008)
J Am Med Assoc
, vol.299
, pp. 2413-2422
-
-
Parienti, J.J.1
Thirion, M.2
Megarbane, B.3
-
16
-
-
0035827890
-
Complications of femoral and subclavian venous catheterization in critically ill patients. A randomized controlled trial
-
Merrer J, Jonghe BD, Golliot F et al. Complications of femoral and subclavian venous catheterization in critically ill patients. A randomized controlled trial. JAMA 2001; 286: 700-707
-
(2001)
JAMA
, vol.286
, pp. 700-707
-
-
Merrer, J.1
Jonghe, B.D.2
Golliot, F.3
-
17
-
-
12244306921
-
The incidence of infectious complications of central venous catheters at the subclavian, internal jugular, and femoral sites in an intensive care unit population
-
Deshpande KS, Hatem C, Ulrich HL et al. The incidence of infectious complications of central venous catheters at the subclavian, internal jugular, and femoral sites in an intensive care unit population. Crit Care Med 2005; 33: 13-20
-
(2005)
Crit Care Med
, vol.33
, pp. 13-20
-
-
Deshpande, K.S.1
Hatem, C.2
Ulrich, H.L.3
-
18
-
-
0030131021
-
Physical and biological effects of a surface coating procedure on polyurethane catheters
-
DOI 10.1016/0142-9612(96)86736-6
-
Francois P, Vaudaux P, Nurdin N et al. Physical and biological effects of a surface coating procedure on polyurethane catheters. Biomaterials 1996; 17: 667-678 (Pubitemid 26091217)
-
(1996)
Biomaterials
, vol.17
, Issue.7
, pp. 667-678
-
-
Francois, P.1
Vaudaux, P.2
Nurdin, N.3
Mathieu, H.J.4
Descouts, P.5
Lew, D.P.6
-
19
-
-
0030913799
-
Vascular access thrombosis: What are the possibilities of intervention?
-
Mysliwiec M. Vascular access thrombosis: what are the possibilities of intervention? Nephrol Dial Transplant 1997; 12: 876-878
-
(1997)
Nephrol Dial Transplant
, vol.12
, pp. 876-878
-
-
Mysliwiec, M.1
-
20
-
-
57149139982
-
Surface-treated catheters-A review
-
Dwyer A. Surface-treated catheters-a review. Semin Dial 2008; 21: 542-546
-
(2008)
Semin Dial
, vol.21
, pp. 542-546
-
-
Dwyer, A.1
-
21
-
-
0032822611
-
Haemodialysis catheter-related infection: Time for action
-
Canaud B. Haemodialysis catheter-related infection: time for action. Nephrol Dial Transplant 1999; 14: 2288-2290
-
(1999)
Nephrol Dial Transplant
, vol.14
, pp. 2288-2290
-
-
Canaud, B.1
-
22
-
-
0034007809
-
Factors influencing function of temporary dialysis catheters
-
Abidi SM, Khan A, Fried LF et al. Factors influencing function of temporary dialysis catheters. Clin Nephrol 2000; 53: 199-205
-
(2000)
Clin Nephrol
, vol.53
, pp. 199-205
-
-
Abidi, S.M.1
Khan, A.2
Fried, L.F.3
-
23
-
-
0023193121
-
Morbidity and mortality of central venous catheter hemodialysis: A review of 10 years' experience
-
Vanholder V, Hoenich N, Ringoir S. Morbidity and mortality of central venous catheter hemodialysis: a review of 10 years' experience. Nephron 1987; 47: 274-279
-
(1987)
Nephron
, vol.47
, pp. 274-279
-
-
Vanholder, V.1
Hoenich, N.2
Ringoir, S.3
-
24
-
-
0033662149
-
Risk of bacteremia from temporary hemodialysis catheters by site of insertion and duration of use: A prospective study
-
Oliver MJ, Callery SM, Thorpe KE et al. Risk of bacteremia from temporary hemodialysis catheters by site of insertion and duration of use: a prospective study. Kidney Int 2000; 58: 2543-2545
-
(2000)
Kidney Int
, vol.58
, pp. 2543-2545
-
-
Oliver, M.J.1
Callery, S.M.2
Thorpe, K.E.3
-
25
-
-
0033000267
-
Outcome and complications of temporary haemodialysis catheters
-
Kairaitis LK, Gottlieb T. Outcome and complications of temporary haemodialysis catheters. NephrolDial Transplant 1999; 14: 1710-1714
-
(1999)
NephrolDial Transplant
, vol.14
, pp. 1710-1714
-
-
Kairaitis, L.K.1
Gottlieb, T.2
-
26
-
-
0024818093
-
Infection of hemodialysis catheters: Incidence and mechanisms
-
Almirall J, Gonzalez J, Rello J et al. Infection of hemodialysis catheters: incidence and mechanisms. Am J Nephrol 1989; 9: 454-459
-
(1989)
Am J Nephrol
, vol.9
, pp. 454-459
-
-
Almirall, J.1
Gonzalez, J.2
Rello, J.3
-
27
-
-
73449110151
-
Does heparin coating improve patency or reduce infection of tunneled dialysis catheters?
-
Jain G, Allon M, Saddekni S et al. Does heparin coating improve patency or reduce infection of tunneled dialysis catheters? Clin J Am Soc Nephrol 2009; 4: 1787-1790
-
(2009)
Clin J Am Soc Nephrol
, vol.4
, pp. 1787-1790
-
-
Jain, G.1
Allon, M.2
Saddekni, S.3
-
28
-
-
0029789231
-
Surface heparinization of central venous catheters reduces microbial colonization in vitro and in vivo: Results from a prospective, randomized trial
-
Appelgren P, Ransjo U, Bindslev L et al. Surface heparinization of central venous catheters reduces microbial colonization in vitro and in vivo: results from a prospective, randomized trial. Crit Care Med 1996; 24: 1482-1489
-
(1996)
Crit Care Med
, vol.24
, pp. 1482-1489
-
-
Appelgren, P.1
Ransjo, U.2
Bindslev, L.3
-
29
-
-
77954772662
-
Bismuth coating of nontunneled haemodialysis catheters reduces bacterial colonization: A randomized controlled trial
-
Schindler R, Heemann U, Haug U et al. Bismuth coating of nontunneled haemodialysis catheters reduces bacterial colonization: a randomized controlled trial. Nephrol Dial Transplant 2010; 25: 2651-2656
-
(2010)
Nephrol Dial Transplant
, vol.25
, pp. 2651-2656
-
-
Schindler, R.1
Heemann, U.2
Haug, U.3
|