메뉴 건너뛰기




Volumn 48, Issue 1, 2011, Pages 28-39

Comparison of the Micro-g LaCoste gPhone-054 spring gravimeter and the GWR-C026 superconducting gravimeter in Strasbourg (France) using a 300-day time series

Author keywords

[No Author keywords available]

Indexed keywords

ABSOLUTE GRAVITY; CO-LOCATED; COMPARATIVE ANALYSIS; CRITICAL POINTS; DRIFT RATES; GRAVITY CHANGES; INCREASED TEMPERATURE; LONG TERM STABILITY; NOISE LEVELS; NON-LINEAR; SEISMIC FREQUENCIES; SPECTRAL BAND; SPECTRAL DOMAINS; SUPERCONDUCTING GRAVIMETER; THERMAL SYSTEMS;

EID: 79551476592     PISSN: 00261394     EISSN: 16817575     Source Type: Journal    
DOI: 10.1088/0026-1394/48/1/003     Document Type: Article
Times cited : (50)

References (50)
  • 1
    • 0003734562 scopus 로고
    • Berlin: de Gruyter
    • Torge W 1989 Gravimetry (Berlin: de Gruyter)
    • (1989) Gravimetry
    • Torge, W.1
  • 2
    • 79551499635 scopus 로고    scopus 로고
    • Gravimetric methods-absolute gravimeter: Instruments concepts and implementation
    • ed G Schubert Oxford: Elsevier
    • Niebauer T 2007 Gravimetric methods-absolute gravimeter: instruments concepts and implementation Treatise on Geophysics vol 3 ed G Schubert (Oxford: Elsevier) pp 43-64
    • (2007) Treatise on Geophysics , vol.3 , pp. 43-64
    • Niebauer, T.1
  • 4
    • 0034464077 scopus 로고    scopus 로고
    • Time variations in gravity and inferences on the earth's structure and dynamics
    • Hinderer J and Crossley D-J 2000 Time variations in gravity and inferences on the Earth's structure and dynamics Surv. Geophys. 21 1-45
    • (2000) Surv. Geophys , vol.21 , pp. 1-45
    • Hinderer, J.1    Crossley, D.-J.2
  • 6
    • 0000001301 scopus 로고    scopus 로고
    • The superconducting gravimeter
    • Goodkind J-M 1999 The superconducting gravimeter Rev. Sci. Instrum. 70 4131-52
    • (1999) Rev. Sci. Instrum. , vol.70 , pp. 4131-4152
    • Goodkind, J.-M.1
  • 7
    • 34248372043 scopus 로고    scopus 로고
    • Is the instrumental drift of superconducting gravimeters a linear or exponential function of time?
    • Van Camp M and Francis O 2007 Is the instrumental drift of superconducting gravimeters a linear or exponential function of time? J. Geodesy 81 337-44
    • (2007) J. Geodesy , vol.81 , pp. 337-344
    • Van Camp, M.1    Francis, O.2
  • 8
    • 8744311482 scopus 로고    scopus 로고
    • Regional gravity variations in Europe from superconducting gravimeters
    • Crossley D-J, Hinderer J and Boy J-P 2004 Regional gravity variations in Europe from superconducting gravimeters J. Geodyn. 38 325-42
    • (2004) J. Geodyn , vol.38 , pp. 325-342
    • Crossley, D.-J.1    Hinderer, J.2    Boy, J.-P.3
  • 11
    • 3142621926 scopus 로고    scopus 로고
    • Studies of tides and instrumental performance of three gravimeters at Cueva de los Verdes (Lanzarote, Spain)
    • Arnoso J, Vieira R, Velez E J, Van Ruymbeke M and Venedikov A P 2001 Studies of tides and instrumental performance of three gravimeters at Cueva de los Verdes (Lanzarote, Spain) J. Geod. Soc. Japan 47 70-5
    • (2001) J. Geod. Soc. Japan , vol.47 , pp. 70-75
    • Arnoso, J.1    Vieira, R.2    Velez, E.J.3    Van Ruymbeke, M.4    Venedikov, A.P.5
  • 12
    • 8744233537 scopus 로고    scopus 로고
    • Aspects of gravimeter calibration by time domain comparison of gravity records
    • Meurers B 2002 Aspects of gravimeter calibration by time domain comparison of gravity records Bull. Inform. Marees Terrestres 135 10643-50
    • (2002) Bull. Inform. Marees Terrestres , vol.135 , pp. 10643-10650
    • Meurers, B.1
  • 13
    • 79551482860 scopus 로고    scopus 로고
    • Micro-g LaCoste, Inc. 2008 gPhone/P. E. T Hardware Manual V1
    • Micro-g LaCoste, Inc. 2008 gPhone/P. E. T Hardware Manual V1
  • 14
    • 79551477331 scopus 로고    scopus 로고
    • Scintrex Limited 1995 CG-3/3M Autograv automated gravity meter operator manual
    • Scintrex Limited 1995 CG-3/3M Autograv automated gravity meter operator manual
  • 16
    • 79551487402 scopus 로고    scopus 로고
    • On the accuracy of the calibration of superconducting gravimeters using absolute and spring sensors: A critical comparison
    • at press
    • Riccardi U, Rosat S and Hinderer J 2010 On the accuracy of the calibration of superconducting gravimeters using absolute and spring sensors: a critical comparison Pure Appl Geophys. at press
    • (2010) Pure Appl. Geophys
    • Riccardi, U.1    Rosat, S.2    Hinderer, J.3
  • 17
    • 79551475443 scopus 로고    scopus 로고
    • Scintrex Limited 2006 CG5 Autograv automated gravity meter operator manual Rev. 4
    • Scintrex Limited 2006 CG5 Autograv automated gravity meter operator manual (Rev. 4)
  • 18
    • 31744443170 scopus 로고    scopus 로고
    • On the capability of recording gravity stations to detect signals coming from volcanic activity: The case of Mt. Vesuvius
    • Berrino G, Corrado G and Riccardi U 2006 On the capability of recording gravity stations to detect signals coming from volcanic activity: the case of Mt. Vesuvius J. Volcanol. Geotherm. Res. 150 270-82
    • (2006) J. Volcanol. Geotherm. Res. , vol.150 , pp. 270-282
    • Berrino, G.1    Corrado, G.2    Riccardi, U.3
  • 19
    • 84862198738 scopus 로고    scopus 로고
    • The automated Burris gravity meter-a new instrument using an old principle
    • St Petersburg, Russia, 20-23 August 2007
    • Jentzsch G 2008 The automated Burris gravity meter-a new instrument using an old principle Proc. Symp. on Terrestrial Gravimetry: Static and Mobile Measurements (St Petersburg, Russia, 20-23 August 2007)
    • (2008) Proc. Symp. on Terrestrial Gravimetry: Static and Mobile Measurements
    • Jentzsch, G.1
  • 20
    • 72049118167 scopus 로고    scopus 로고
    • Analysis of a 10-year (1997-2007) record of time-varying gravity in Strasbourg using absolute and superconducting gravimeters: New results on the calibration and comparison with GPS height changes and hydrology
    • Rosat S, Boy J-P, Ferhat G, Hinderer J, Amalvict M, Gegout P and Luck B 2009 Analysis of a 10-year (1997-2007) record of time-varying gravity in Strasbourg using absolute and superconducting gravimeters: new results on the calibration and comparison with GPS height changes and hydrology J. Geodyn. 48 360-5
    • (2009) J. Geodyn , vol.48 , pp. 360-365
    • Rosat, S.1    Boy, J.-P.2    Ferhat, G.3    Hinderer, J.4    Amalvict, M.5    Gegout, P.6    Luck, B.7
  • 21
    • 85015701550 scopus 로고    scopus 로고
    • A three year comparison between a superconducting gravimeter (GWR C026) and an absolute gravimeter (FG5#206) in Strasbourg (France)
    • Amalvict M, Hinderer J, Boy J-P and Gegout P 2001 A three year comparison between a superconducting gravimeter (GWR C026) and an absolute gravimeter (FG5#206) in Strasbourg (France) J. Geod. Soc. Japan. 47 334-40
    • (2001) J. Geod. Soc. Japan , vol.47 , pp. 334-340
    • Amalvict, M.1    Hinderer, J.2    Boy, J.-P.3    Gegout, P.4
  • 22
    • 8744266121 scopus 로고    scopus 로고
    • Long-term and seasonal gravity changes at the Strasbourg station and their relation to crustal deformation and hydrology
    • Amalvict M, Hinderer J, Mäkinen J, Rosat S and Rogister Y 2004 Long-term and seasonal gravity changes at the Strasbourg station and their relation to crustal deformation and hydrology J. Geodyn. 38 343-53
    • (2004) J. Geodyn , vol.38 , pp. 343-353
    • Amalvict, M.1    Hinderer, J.2    Mäkinen, J.3    Rosat, S.4    Rogister, Y.5
  • 24
    • 0036954699 scopus 로고    scopus 로고
    • Changes in the instrumental sensitivity for some feedback equipping LaCoste & Romberg gravity meters
    • Riccardi U and Berrino G 2002 Changes in the instrumental sensitivity for some feedback equipping LaCoste & Romberg gravity meters Metrologia 39 509-15
    • (2002) Metrologia , vol.39 , pp. 509-515
    • Riccardi, U.1    Berrino, G.2
  • 25
    • 0242652679 scopus 로고    scopus 로고
    • Tidal gravity recording at Brussels with a Scintrex CG-3M gravity meter
    • Ducarme B and Somerhausen A 1997 Tidal gravity recording at Brussels with a Scintrex CG-3M gravity meter Bull. Inform. Marees Terrestres 126 9611-34
    • (1997) Bull. Inform. Marees Terrestres , vol.126 , pp. 9611-9634
    • Ducarme, B.1    Somerhausen, A.2
  • 27
    • 0001274741 scopus 로고
    • Accurate instrumental phase lag determination for feedback gravimeters
    • Wenzel H-G 1994 Accurate instrumental phase lag determination for feedback gravimeters Bull. Inform. Marees Terrestres 118 8735-52
    • (1994) Bull. Inform. Marees Terrestres , vol.118 , pp. 8735-8752
    • Wenzel, H.-G.1
  • 28
    • 0037328015 scopus 로고    scopus 로고
    • Validating Earth and ocean tide models using tidal gravity measurements
    • Baker T-F and Bos M-S 2003 Validating Earth and ocean tide models using tidal gravity measurements Geophys. J. Int. 152 468-85
    • (2003) Geophys. J. Int. , vol.152 , pp. 468-485
    • Baker, T.-F.1    Bos, M.-S.2
  • 29
    • 0000450197 scopus 로고    scopus 로고
    • The Nanogal software: Earth tide data processing package ETERNA 3.30
    • Wenzel H-G 1996 The Nanogal software: Earth tide data processing package ETERNA 3.30 Bull. Inform. Marees Terrestres 124 9425-39
    • (1996) Bull. Inform. Marees Terrestres , vol.124 , pp. 9425-9439
    • Wenzel, H.-G.1
  • 31
    • 0030209380 scopus 로고    scopus 로고
    • Tidal loading in south western Europe: A test area
    • Francis O and Melchior P 1996 Tidal loading in south western Europe: a test area Geophys. Res. Lett. 23 2251-4
    • (1996) Geophys. Res. Lett. , vol.23 , pp. 2251-2254
    • Francis, O.1    Melchior, P.2
  • 32
    • 0013349216 scopus 로고    scopus 로고
    • Proper usage of the ICET databank: Comparison with theoretical applications on Earth models
    • ed B Ducarme and P Paquet Brussels: Observatoire Royal de Belgique
    • Melchior P and Francis O 1998 Proper usage of the ICET databank: comparison with theoretical applications on Earth models Proc. 13th Int. Symp. on Earth Tides ed B Ducarme and P Paquet (Brussels: Observatoire Royal de Belgique)
    • (1998) Proc. 13th Int. Symp. on Earth Tides
    • Melchior, P.1    Francis, O.2
  • 33
    • 0042816520 scopus 로고    scopus 로고
    • A comparison of tidal ocean loading models using superconducting gravimeter data
    • Boy J-P, Llubes M, Hinderer J and Florsch N 2003 A comparison of tidal ocean loading models using superconducting gravimeter data J. Geophys. Res. 108 2193
    • (2003) J. Geophys. Res. , vol.108 , pp. 2193
    • Boy, J.-P.1    Llubes, M.2    Hinderer, J.3    Florsch, N.4
  • 38
    • 79551473775 scopus 로고    scopus 로고
    • Bos M S and Scherneck H-G, website
    • Bos M S and Scherneck H-G, website: http://129.16.208.24/loading/
  • 39
    • 42549128526 scopus 로고    scopus 로고
    • Etude des ondes de marée sur les plateux continentaux
    • Université de Toulouse III, Ecole Doctorale des Sciences de l'Univers, de l'Environnement et de l'Espace
    • Letellier T 2004 Etude des ondes de marée sur les plateux continentaux Thèse Doctorale Université de Toulouse III, Ecole Doctorale des Sciences de l'Univers, de l'Environnement et de l'Espace
    • (2004) Thèse Doctorale
    • Letellier, T.1
  • 40
    • 33845947339 scopus 로고    scopus 로고
    • Modelling the global ocean tides: Modern insights from FES2004
    • Lyard F, Lefévre F, Letellier T and Francis O 2006 Modelling the global ocean tides: Modern insights from FES2004 Ocean Dyn. 56 394-415
    • (2006) Ocean Dyn , vol.56 , pp. 394-415
    • Lyard, F.1    Lefévre, F.2    Letellier, T.3    Francis, O.4
  • 41
    • 0028315660 scopus 로고
    • A new databank for tidal gravity measurements (DB92)
    • Melchior P 1994 A new databank for tidal gravity measurements (DB92) Phys. Earth Planet. Inter. 82 125-55
    • (1994) Phys. Earth Planet. Inter , vol.82 , pp. 125-155
    • Melchior, P.1
  • 42
  • 45
    • 0029479203 scopus 로고
    • From Chandler wobble to free oscillations: Comparison of cryogenic gravimeters and other instruments in a wide period range
    • Richter B, Wenzel H-G, Zürn W and Klopping F 1995 From Chandler wobble to free oscillations: comparison of cryogenic gravimeters and other instruments in a wide period range Phys. Earth Planet. Inter. 91 131-48
    • (1995) Phys. Earth Planet. Inter , vol.91 , pp. 131-148
    • Richter, B.1    Wenzel, H.-G.2    Zürn, W.3    Klopping, F.4
  • 46
    • 0033376123 scopus 로고    scopus 로고
    • Noise levels of superconducting gravimeters at seismic frequencies
    • Banka D and Crossley D-J 1999 Noise levels of superconducting gravimeters at seismic frequencies Geophys. J. Int. 139 87-97
    • (1999) Geophys. J. Int. , vol.139 , pp. 87-97
    • Banka, D.1    Crossley, D.-J.2
  • 47
    • 8744223144 scopus 로고    scopus 로고
    • Performance of superconducting gravimeters from long-period seismology to tides
    • Rosat S, Hinderer J, Crossley D and Boy J-P 2004 Performance of superconducting gravimeters from long-period seismology to tides J. Geodyn. 38 461-76
    • (2004) J. Geodyn , vol.38 , pp. 461-476
    • Rosat, S.1    Hinderer, J.2    Crossley, D.3    Boy, J.-P.4
  • 48
    • 0345581324 scopus 로고    scopus 로고
    • The search for the Slichter mode: Comparison of noise levels of superconducting gravimeters and investigation of a stacking method
    • Rosat S, Hinderer J, Crossley D and Rivera L 2003 The search for the Slichter mode: comparison of noise levels of superconducting gravimeters and investigation of a stacking method Phys. Earth Planet. Inter. 140 183-202
    • (2003) Phys. Earth Planet. Inter , vol.140 , pp. 183-202
    • Rosat, S.1    Hinderer, J.2    Crossley, D.3    Rivera, L.4
  • 49
    • 0005668177 scopus 로고
    • The precision of the development of the tidal generating potential and some explanatory notes
    • Qinwen X 1989 The precision of the development of the tidal generating potential and some explanatory notes Bull. Inform. Marees Terrestres 105 7396-404
    • (1989) Bull. Inform. Marees Terrestres , vol.105 , pp. 7396-7404
    • Qinwen, X.1
  • 50
    • 0003904206 scopus 로고
    • Observations and modelling of seismic background noise
    • US Department of Interior, Geological Survey, Albuquerque, NM
    • Peterson J 1993 Observations and modelling of seismic background noise Open-File Report 93-332 US Department of Interior, Geological Survey, Albuquerque, NM
    • (1993) Open-file Report 93-332
    • Peterson, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.