메뉴 건너뛰기




Volumn 64, Issue 5, 2004, Pages 887-891

Novel algorithm for improving accuracy of ultrasound measurement of residual urine volume according to bladder shape

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; BLADDER; CALCULATION; CATHETERIZATION; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RESIDUAL URINE; STATISTICAL ANALYSIS; ULTRASOUND;

EID: 7944234949     PISSN: 00904295     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.urology.2004.06.054     Document Type: Article
Times cited : (28)

References (18)
  • 1
    • 0014076793 scopus 로고
    • Ultrasonic studies of bladder
    • J.H. Holmes Ultrasonic studies of bladder J Urol 97 1967 654 663
    • (1967) J Urol , vol.97 , pp. 654-663
    • Holmes, J.H.1
  • 2
    • 0022004687 scopus 로고
    • Ultrasound assessment of residual urine: A quantitative method
    • C.J. Beacock, E.E. Roberts, R.W. Rees Ultrasound assessment of residual urine a quantitative method Br J Urol 57 1985 410 413
    • (1985) Br J Urol , vol.57 , pp. 410-413
    • Beacock, C.J.1    Roberts, E.E.2    Rees, R.W.3
  • 3
    • 0025335053 scopus 로고
    • Ultrasound measurement of urine volume of children with neurogenic bladder
    • T.L. Massagli, K.M. Jaffe, D.D. Cardenas Ultrasound measurement of urine volume of children with neurogenic bladder Dev Med Child Neurol 32 1990 314 318
    • (1990) Dev Med Child Neurol , vol.32 , pp. 314-318
    • Massagli, T.L.1    Jaffe, K.M.2    Cardenas, D.D.3
  • 4
    • 0027971971 scopus 로고
    • The accuracy of portable ultrasound scanning in the measurement of residual urine volume
    • G.M. Coombes, R.J. Millard The accuracy of portable ultrasound scanning in the measurement of residual urine volume J Urol 152 1994 2083 2085
    • (1994) J Urol , vol.152 , pp. 2083-2085
    • Coombes, G.M.1    Millard, R.J.2
  • 5
    • 0028152572 scopus 로고
    • Use of a portable ultrasound device to measure post-void residual volume among incontinent nursing home residents
    • J.G. Ouslander, S. Simmons, E. Tuico Use of a portable ultrasound device to measure post-void residual volume among incontinent nursing home residents J Am Geriatr Soc 42 1994 1189 1192
    • (1994) J Am Geriatr Soc , vol.42 , pp. 1189-1192
    • Ouslander, J.G.1    Simmons, S.2    Tuico, E.3
  • 6
    • 0022543249 scopus 로고
    • Accuracy and repeatability of bladder volume measurement using ultrasonic imaging
    • J. Griffiths, A. Murray, D. Ramsden Accuracy and repeatability of bladder volume measurement using ultrasonic imaging J Urol 136 1986 808 812
    • (1986) J Urol , vol.136 , pp. 808-812
    • Griffiths, J.1    Murray, A.2    Ramsden, D.3
  • 7
    • 0024549743 scopus 로고
    • Transvaginal ultrasound in the assessment of bladder volumes in women
    • B.T. Haylen, M.I. Frazer, J.R. Sutherst Transvaginal ultrasound in the assessment of bladder volumes in women Br J Urol 63 1989 149 151
    • (1989) Br J Urol , vol.63 , pp. 149-151
    • Haylen, B.T.1    Frazer, M.I.2    Sutherst, J.R.3
  • 8
    • 0342429685 scopus 로고
    • Sonocystography: A method for measuring residual urine
    • K. West Sonocystography a method for measuring residual urine Scand J Urol Nephrol 1 1967 68 73
    • (1967) Scand J Urol Nephrol , vol.1 , pp. 68-73
    • West, K.1
  • 9
    • 0020635753 scopus 로고
    • The estimation of bladder volume by sonocytography
    • O.W. Hakenberg, R.L. Ryall, S.L. Langlois The estimation of bladder volume by sonocytography J Urol 130 1983 249 251
    • (1983) J Urol , vol.130 , pp. 249-251
    • Hakenberg, O.W.1    Ryall, R.L.2    Langlois, S.L.3
  • 10
    • 0020536645 scopus 로고
    • The accuracy of ultrasound in the measurement of changes in bladder volume
    • G.J. Poston, A.E.A. Joseph, P.T. Riddle The accuracy of ultrasound in the measurement of changes in bladder volume Br J Urol 55 1983 361 363
    • (1983) Br J Urol , vol.55 , pp. 361-363
    • Poston, G.J.1    Joseph, A.E.A.2    Riddle, P.T.3
  • 11
    • 0023271846 scopus 로고
    • Real-time ultrasound measurement of bladder volume: A comparative study of three methods
    • G.G. Hartnell, E.A. Kiely, G. Williams Real-time ultrasound measurement of bladder volume a comparative study of three methods Br J Radiol 60 1987 1063 1065
    • (1987) Br J Radiol , vol.60 , pp. 1063-1065
    • Hartnell, G.G.1    Kiely, E.A.2    Williams, G.3
  • 13
    • 0023197322 scopus 로고
    • Measurement of bladder volume by real-time ultrasound
    • E.A. Kiely, G.G. Hartnell, R.N. Gibson Measurement of bladder volume by real-time ultrasound Br J Urol 60 1987 33 35
    • (1987) Br J Urol , vol.60 , pp. 33-35
    • Kiely, E.A.1    Hartnell, G.G.2    Gibson, R.N.3
  • 14
    • 0030951316 scopus 로고    scopus 로고
    • Accuracy of residual urine measurement in men: Comparison between real-time ultrasonography and catheterization
    • N. Simforoosh, F. Dadkhah, S.Y. Hosseini Accuracy of residual urine measurement in men comparison between real-time ultrasonography and catheterization J Urol 158 1997 59 61
    • (1997) J Urol , vol.158 , pp. 59-61
    • Simforoosh, N.1    Dadkhah, F.2    Hosseini, S.Y.3
  • 15
    • 0032792957 scopus 로고    scopus 로고
    • The accuracy of portable abdominal ultrasound equipment in measuring postvoid residual volume
    • B. Alnaif, H.P. Drutz The accuracy of portable abdominal ultrasound equipment in measuring postvoid residual volume Int Urogynecol J Pelvic Floor Dysfunct 10 1999 215 218
    • (1999) Int Urogynecol J Pelvic Floor Dysfunct , vol.10 , pp. 215-218
    • Alnaif, B.1    Drutz, H.P.2
  • 16
    • 0033986554 scopus 로고    scopus 로고
    • Bladder volume determination: Portable 3-D versus stationary 2-D ultrasound device
    • P. Schnider, P. Birner, A. Gendo Bladder volume determination portable 3-D versus stationary 2-D ultrasound device Arch Phys Med Rehabil 81 2000 18 21
    • (2000) Arch Phys Med Rehabil , vol.81 , pp. 18-21
    • Schnider, P.1    Birner, P.2    Gendo, A.3
  • 17
    • 0025247805 scopus 로고
    • Bladder volume determination using a dedicated, portable ultrasound scanner
    • R.C. Ireton, J.N. Krieger, D.D. Cardenas Bladder volume determination using a dedicated, portable ultrasound scanner J Urol 143 1990 909 911
    • (1990) J Urol , vol.143 , pp. 909-911
    • Ireton, R.C.1    Krieger, J.N.2    Cardenas, D.D.3
  • 18
    • 0030826957 scopus 로고    scopus 로고
    • Three-dimensional ultrasound device for rapid determination of bladder volume
    • L.S. Marks, F.J. Dorey, M.L. Macairan Three-dimensional ultrasound device for rapid determination of bladder volume Urology 50 1997 341 347
    • (1997) Urology , vol.50 , pp. 341-347
    • Marks, L.S.1    Dorey, F.J.2    MacAiran, M.L.3