메뉴 건너뛰기




Volumn 101, Issue 4, 2004, Pages 700-703

Perfusion imaging of high-grade gliomas: A comparison between contrast harmonic and magnetic resonance imaging: Technical note

Author keywords

Brain neoplasm; Cerebral blood volume; Glioma; Perfusion imaging; Ultrasonography

Indexed keywords

ADULT; AGED; AREA UNDER THE CURVE; ARTICLE; BLOOD VOLUME; BRAIN BLOOD FLOW; BRAIN CIRCULATION; BRAIN PERFUSION; BRAIN TISSUE; BRAIN TUMOR; CASE REPORT; CONTRAST HARMONIC IMAGING; COST EFFECTIVENESS ANALYSIS; DIAGNOSTIC IMAGING; DISEASE SEVERITY; ECHOGRAPHY; FEMALE; FOLLOW UP; GLIOMA; HISTOLOGY; HUMAN; IMAGE ENHANCEMENT; INTERMETHOD COMPARISON; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; TUMOR LOCALIZATION; TUMOR RECURRENCE; BLOOD FLOW; COMPARATIVE STUDY; DOPPLER ECHOGRAPHY; METHODOLOGY; MIDDLE AGED; PATHOLOGY; REFERENCE VALUE; VASCULARIZATION;

EID: 7944220221     PISSN: 00223085     EISSN: 00223085     Source Type: Journal    
DOI: 10.3171/jns.2004.101.4.0700     Document Type: Article
Times cited : (16)

References (17)
  • 1
    • 0036867934 scopus 로고    scopus 로고
    • Dynamic susceptibility MRI of gliomas
    • Aronen HJ, Perkio J: Dynamic susceptibility MRI of gliomas. Neuroimaging Clin N Am 12:501-523, 2002
    • (2002) Neuroimaging Clin N Am , vol.12 , pp. 501-523
    • Aronen, H.J.1    Perkio, J.2
  • 2
    • 0033019067 scopus 로고    scopus 로고
    • Postoperative neuroimaging of high-grade gliomas: Comparison of transcranial sonography, magnetic resonance imaging, and computed tomography
    • Becker G, Hofmann E, Woydt M, et al: Postoperative neuroimaging of high-grade gliomas: comparison of transcranial sonography, magnetic resonance imaging, and computed tomography. Neurosurgery 44:469-478, 1999
    • (1999) Neurosurgery , vol.44 , pp. 469-478
    • Becker, G.1    Hofmann, E.2    Woydt, M.3
  • 3
    • 0027985396 scopus 로고
    • Reliability of transcranial color-coded real-time sonography in assessment of brain tumors: Correlation of ultrasound, computed tomography and biopsy findings
    • Becker G, Krone A, Koulis D, et al: Reliability of transcranial color-coded real-time sonography in assessment of brain tumors: correlation of ultrasound, computed tomography and biopsy findings. Neuroradiology 36:585-590, 1994
    • (1994) Neuroradiology , vol.36 , pp. 585-590
    • Becker, G.1    Krone, A.2    Koulis, D.3
  • 4
    • 0035912617 scopus 로고    scopus 로고
    • Microbubble contrast agents: A new era in ultrasound
    • Blomley MJK, Cooke JC, Unger EC, et al: Microbubble contrast agents: a new era in ultrasound. Br Med J 322:1222-1225, 2001
    • (2001) Br Med J , vol.322 , pp. 1222-1225
    • Blomley, M.J.K.1    Cooke, J.C.2    Unger, E.C.3
  • 5
    • 0030059706 scopus 로고    scopus 로고
    • Harmonic imaging with ultrasound contrast agents
    • Burns PN: Harmonic imaging with ultrasound contrast agents. Clin Radiol 51 (Suppl 1):50-55, 1996
    • (1996) Clin Radiol , vol.51 , Issue.1 SUPPL. , pp. 50-55
    • Burns, P.N.1
  • 6
    • 0037227079 scopus 로고    scopus 로고
    • Contrast burst depletion imaging (CODIM): A new imaging procedure and analysis method for semiquantitative ultrasonic perfusion imaging
    • Eyding J, Wilkening W, Reckhardt M, et al: Contrast burst depletion imaging (CODIM): a new imaging procedure and analysis method for semiquantitative ultrasonic perfusion imaging. Stroke 34:77-83, 2003
    • (2003) Stroke , vol.34 , pp. 77-83
    • Eyding, J.1    Wilkening, W.2    Reckhardt, M.3
  • 7
    • 0033793457 scopus 로고    scopus 로고
    • Ultrasonic evaluation of pathological brain perfusion in acute stroke using second harmonic imaging
    • Federlein J, Postert T, Meves S, et al: Ultrasonic evaluation of pathological brain perfusion in acute stroke using second harmonic imaging. J Neurol Neurosurg Psychiatry 69:616-622, 2000
    • (2000) J Neurol Neurosurg Psychiatry , vol.69 , pp. 616-622
    • Federlein, J.1    Postert, T.2    Meves, S.3
  • 8
    • 0029830664 scopus 로고    scopus 로고
    • Analysis of regional cerebral blood flow in dogs, with an experimental microbubblebased US contrast agent
    • Greenberg RS, Taylor GA, Stapleton JC, et al: Analysis of regional cerebral blood flow in dogs, with an experimental microbubblebased US contrast agent. Radiology 201:119-123, 1996
    • (1996) Radiology , vol.201 , pp. 119-123
    • Greenberg, R.S.1    Taylor, G.A.2    Stapleton, J.C.3
  • 9
    • 0037370052 scopus 로고    scopus 로고
    • Second harmonic imaging: A new ultrasound technique to assess human brain tumour perfusion
    • Harrer JU, Mayfrank L, Mull M, et al: Second harmonic imaging: A new ultrasound technique to assess human brain tumour perfusion. J Neurol Neurosurg Psychiatry 74:333-338, 2003
    • (2003) J Neurol Neurosurg Psychiatry , vol.74 , pp. 333-338
    • Harrer, J.U.1    Mayfrank, L.2    Mull, M.3
  • 10
    • 0034838839 scopus 로고    scopus 로고
    • Ultrasound of focal liver lesions
    • Harvey CJ, Albrecht T: Ultrasound of focal liver lesions. Eur Radiol 11:1578-1593, 2001
    • (2001) Eur Radiol , vol.11 , pp. 1578-1593
    • Harvey, C.J.1    Albrecht, T.2
  • 11
    • 0036150885 scopus 로고    scopus 로고
    • Abnormalities of the recirculation phase of contrast agent bolus passage in cerebral gliomas: Comparison with relative blood volume and tumor grade
    • Jackson A, Kassner A, Annesley-Williams D, et al: Abnormalities of the recirculation phase of contrast agent bolus passage in cerebral gliomas: comparison with relative blood volume and tumor grade. AJNR 23:7-14, 2002
    • (2002) AJNR , vol.23 , pp. 7-14
    • Jackson, A.1    Kassner, A.2    Annesley-Williams, D.3
  • 12
    • 0036186445 scopus 로고    scopus 로고
    • High-grade gliomas and solitary metastases: Differentiation by using perfusion and proton spectroscopic MR imaging
    • Law M, Cha S, Knopp EA, et al: High-grade gliomas and solitary metastases: differentiation by using perfusion and proton spectroscopic MR imaging. Radiology 222:715-721, 2002
    • (2002) Radiology , vol.222 , pp. 715-721
    • Law, M.1    Cha, S.2    Knopp, E.A.3
  • 13
    • 0036791887 scopus 로고    scopus 로고
    • Comparison between echo contrast agent-specific imaging modes and perfusionweighted magnetic resonance imaging for the assessment of brain perfusion
    • Meves SH, Wilkening W, Thies T, et al: Comparison between echo contrast agent-specific imaging modes and perfusionweighted magnetic resonance imaging for the assessment of brain perfusion. Stroke 33:2433-2437, 2002
    • (2002) Stroke , vol.33 , pp. 2433-2437
    • Meves, S.H.1    Wilkening, W.2    Thies, T.3
  • 14
    • 0034936513 scopus 로고    scopus 로고
    • Transcranial sonography of brain tumors in the adult: An in vitro and in vivo study
    • Meyer K, Seidel G, Knopp U: Transcranial sonography of brain tumors in the adult: an in vitro and in vivo study. J Neuroimaging 11:287-292, 2001
    • (2001) J Neuroimaging , vol.11 , pp. 287-292
    • Meyer, K.1    Seidel, G.2    Knopp, U.3
  • 15
    • 0027496845 scopus 로고
    • Second harmonic ultrasonic blood perfusion measurement
    • Schrope B, Newhouse VL: Second harmonic ultrasonic blood perfusion measurement. Ultrasound Med Biol 19:567-579, 1993
    • (1993) Ultrasound Med Biol , vol.19 , pp. 567-579
    • Schrope, B.1    Newhouse, V.L.2
  • 16
    • 0034750046 scopus 로고    scopus 로고
    • Harmonic imaging-a new method for the sonographic assessment of cerebral perfusion
    • Seidel G, Meyer K: Harmonic imaging-a new method for the sonographic assessment of cerebral perfusion. Eur J Ultrasound 14:103-113, 2001
    • (2001) Eur J Ultrasound , vol.14 , pp. 103-113
    • Seidel, G.1    Meyer, K.2
  • 17
    • 0031797298 scopus 로고    scopus 로고
    • Correlation of MR imaging-determined cerebral blood volume maps with histologic and angiographic determination of vascularity of gliomas
    • Sugahara T, Korogi Y, Kochi M, et al: Correlation of MR imaging-determined cerebral blood volume maps with histologic and angiographic determination of vascularity of gliomas. AJR 171:1479-1486, 1998
    • (1998) AJR , vol.171 , pp. 1479-1486
    • Sugahara, T.1    Korogi, Y.2    Kochi, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.