Volumn 4, Issue 1, 2011, Pages 78-83

Time spatial labeling inversion pulse cerebral MR angiography without subtraction by use of dual inversion recovery background suppression

Author keywords

Background suppression; Dual IR; MR angiography; Time SLIP

Indexed keywords

ARTICLE; BRAIN BLOOD FLOW; COMPUTER SIMULATION; CONTROLLED STUDY; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RETRIEVAL; IMAGE SUBTRACTION; IMAGING AND DISPLAY; INTERMETHOD COMPARISON; MAGNETIC RESONANCE ANGIOGRAPHY; NEUROIMAGING; PHANTOM; PRIORITY JOURNAL; SIGNAL DETECTION; TIME SPATIAL LABELING INVERSION PULSE;

EID: 79251628999     PISSN: 18650333     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12194-010-0108-8     Document Type: Article
Times cited : (5)

References (18)
  • 1
    • 33847239121 scopus 로고    scopus 로고
    • Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis
    • 10.1148/radiol.2423061640 17213364
    • PH Kuo E Kanal AK Abu-Alfa SE Cowper 2007 Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis Radiology 242 3 647 649 10.1148/radiol.2423061640 17213364
    • (2007) Radiology , vol.242 , Issue.3 , pp. 647-649
    • Kuo, P.H.1    Kanal, E.2    Abu-Alfa, A.K.3    Cowper, S.E.4
  • 3
    • 47249139148 scopus 로고    scopus 로고
    • Nonenhanced MR angiography
    • 10.1148/radiol.2481071497 18566168
    • M Miyazaki VS Lee 2008 Nonenhanced MR angiography Radiology 248 1 20 43 10.1148/radiol.2481071497 18566168
    • (2008) Radiology , vol.248 , Issue.1 , pp. 20-43
    • Miyazaki, M.1    Lee, V.S.2
  • 4
    • 0036828455 scopus 로고    scopus 로고
    • Renal arteries: Navigator-gated balanced fast field-echo projection MR angiography with aortic spin labeling: Initial experience
    • 10.1148/radiol.2252011366 12409599
    • E Spuentrup WJ Manning P Börnert KV Kissinger RM Botnar M Stuber 2002 Renal arteries: navigator-gated balanced fast field-echo projection MR angiography with aortic spin labeling: initial experience Radiology 225 2 589 596 10.1148/radiol.2252011366 12409599
    • (2002) Radiology , vol.225 , Issue.2 , pp. 589-596
    • Spuentrup, E.1    Manning, W.J.2    Börnert, P.3    Kissinger, K.V.4    Botnar, R.M.5    Stuber, M.6
  • 5
    • 63649134367 scopus 로고    scopus 로고
    • Non-contrast-enhanced hepatic MR angiography with true steady-state free-precession and time spatial labeling inversion pulse: Optimization of the technique and preliminary results
    • 10.1016/j.ejrad.2007.12.010 18249518
    • K Shimada H Isoda T Okada Y Maetani S Arizono Y Hirokawa T Kamae K Togashi 2009 Non-contrast-enhanced hepatic MR angiography with true steady-state free-precession and time spatial labeling inversion pulse: optimization of the technique and preliminary results Eur J Radiol 70 1 111 117 10.1016/j.ejrad. 2007.12.010 18249518
    • (2009) Eur J Radiol , vol.70 , Issue.1 , pp. 111-117
    • Shimada, K.1    Isoda, H.2    Okada, T.3    Maetani, Y.4    Arizono, S.5    Hirokawa, Y.6    Kamae, T.7    Togashi, K.8
  • 6
    • 66749129051 scopus 로고    scopus 로고
    • Improved arterial visibility using short-tau inversion-recovery (STIR) fat suppression in non-contrast-enhanced time-spatial labeling inversion pulse (Time-SLIP) renal MR angiography (MRA)
    • 10.1002/jmri.21792 19472424
    • T Shonai T Takahashi H Ikeguchi M Miyazaki K Amano M Yui 2009 Improved arterial visibility using short-tau inversion-recovery (STIR) fat suppression in non-contrast-enhanced time-spatial labeling inversion pulse (Time-SLIP) renal MR angiography (MRA) J Magn Reson Imaging 29 6 1471 1477 10.1002/jmri.21792 19472424
    • (2009) J Magn Reson Imaging , vol.29 , Issue.6 , pp. 1471-1477
    • Shonai, T.1    Takahashi, T.2    Ikeguchi, H.3    Miyazaki, M.4    Amano, K.5    Yui, M.6
  • 7
    • 69449095626 scopus 로고    scopus 로고
    • Visualization of external carotid artery and its branches: Non-contrast-enhanced MR angiography using balanced steady-state free-precession sequence and a time-spatial labeling inversion pulse
    • 10.1002/jmri.21883 19711418
    • N Satogami T Okada T Koyama K Gotoh T Kamae K Togashi 2009 Visualization of external carotid artery and its branches: non-contrast-enhanced MR angiography using balanced steady-state free-precession sequence and a time-spatial labeling inversion pulse J Magn Reson Imaging 30 3 678 683 10.1002/jmri.21883 19711418
    • (2009) J Magn Reson Imaging , vol.30 , Issue.3 , pp. 678-683
    • Satogami, N.1    Okada, T.2    Koyama, T.3    Gotoh, K.4    Kamae, T.5    Togashi, K.6
  • 8
    • 67650085276 scopus 로고    scopus 로고
    • Time-resolved three-dimensional magnetic resonance digital subtraction angiography without contrast material in the brain: Initial investigation
    • 10.1002/jmri.21823 19466714
    • M Hori N Shiraga Y Watanabe S Aoki S Isono M Yui K Ohtomo T Araki 2009 Time-resolved three-dimensional magnetic resonance digital subtraction angiography without contrast material in the brain: Initial investigation J Magn Reson Imaging 30 1 214 218 10.1002/jmri.21823 19466714
    • (2009) J Magn Reson Imaging , vol.30 , Issue.1 , pp. 214-218
    • Hori, M.1    Shiraga, N.2    Watanabe, Y.3    Aoki, S.4    Isono, S.5    Yui, M.6    Ohtomo, K.7    Araki, T.8
  • 9
    • 0025875173 scopus 로고
    • Multiple inversion recovery reduces static tissue signal in angiograms
    • 1:STN:280:DyaK3M3mtVeqtg%3D%3D 10.1002/mrm.1910180202 2046511
    • WT Dixon M Sardashti M Castillo GP Stomp 1991 Multiple inversion recovery reduces static tissue signal in angiograms Magn Reson Med 18 2 257 268 1:STN:280:DyaK3M3mtVeqtg%3D%3D 10.1002/mrm.1910180202 2046511
    • (1991) Magn Reson Med , vol.18 , Issue.2 , pp. 257-268
    • Dixon, W.T.1    Sardashti, M.2    Castillo, M.3    Stomp, G.P.4
  • 10
    • 84953656233 scopus 로고
    • 2 diagnostic?
    • DOI 10.1118/1.596111
    • PA Bottomley CJ Hardy RE Argersinger G Allen-Moore 1987 A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic? Med Phys 14 1 1 37 1:STN:280:DyaL2s7nt1CmsQ%3D%3D 10.1118/1.596111 3031439 (Pubitemid 17024353)
    • (1987) Medical Physics , vol.14 , Issue.1 , pp. 1-37
    • Bottomley, P.A.1    Hardy, C.J.2    Argersinger, R.E.3    Allen-Moore, G.4
  • 11
    • 0023286792 scopus 로고
    • MR angiography by selective inversion recovery
    • 1:STN:280:DyaL2s7nt1antQ%3D%3D 10.1002/mrm.1910040214 3561250
    • DG Nishimura A Macovski JM Pauly SM Conolly 1987 MR angiography by selective inversion recovery Magn Reson Med 4 2 193 202 1:STN:280: DyaL2s7nt1antQ%3D%3D 10.1002/mrm.1910040214 3561250
    • (1987) Magn Reson Med , vol.4 , Issue.2 , pp. 193-202
    • Nishimura, D.G.1    MacOvski, A.2    Pauly, J.M.3    Conolly, S.M.4
  • 12
    • 0028153930 scopus 로고
    • Signal targeting with alternating radiofrequency (STAR) sequences: Application to MR angiography
    • 1:STN:280:DyaK2c7otVOmtQ%3D%3D 10.1002/mrm.1910310219 8133761
    • RR Edelman B Siewert M Adamis J Gaa G Laub P Wielopolski 1994 Signal targeting with alternating radiofrequency (STAR) sequences: application to MR angiography Magn Reson Med 31 2 233 238 1:STN:280:DyaK2c7otVOmtQ%3D%3D 10.1002/mrm.1910310219 8133761
    • (1994) Magn Reson Med , vol.31 , Issue.2 , pp. 233-238
    • Edelman, R.R.1    Siewert, B.2    Adamis, M.3    Gaa, J.4    Laub, G.5    Wielopolski, P.6
  • 13
    • 0030958778 scopus 로고    scopus 로고
    • Background suppression with multiple inversion recovery nulling: Applications to projective angiography
    • DOI 10.1002/mrm.1910370615
    • S Mani J Pauly S Conolly C Meyer D Nishimura 1997 Background suppression with multiple inversion recovery nulling: applications to projective angiography Magn Reson Med 37 6 898 905 1:STN:280:DyaK2szitFGgsA%3D%3D 10.1002/mrm. 1910370615 9178242 (Pubitemid 27270768)
    • (1997) Magnetic Resonance in Medicine , vol.37 , Issue.6 , pp. 898-905
    • Mani, S.1    Pauly, J.2    Conolly, S.3    Meyer, C.4    Nishimura, D.5
  • 14
    • 44449087469 scopus 로고    scopus 로고
    • Improvement of chemical shift saturation (CHESS) pulse for MR angiography
    • Y Ishimori A Hiraga T Matsuda H Sashie 2000 Improvement of chemical shift saturation (CHESS) pulse for MR angiography Jpn J Radiol Technol 56 7 929 936
    • (2000) Jpn J Radiol Technol , vol.56 , Issue.7 , pp. 929-936
    • Ishimori, Y.1    Hiraga, A.2    Matsuda, T.3    Sashie, H.4
  • 15
    • 0027940626 scopus 로고
    • Intracranial MR angiography: Comparison of single-volume three-dimensional time-of-flight and multiple overlapping thin slab acquisition techniques
    • 1:STN:280:DyaK2cznvV2itQ%3D%3D 8092035
    • WL Davis DD Blatter HR Harnsberger DL Parker 1994 Intracranial MR angiography: comparison of single-volume three-dimensional time-of-flight and multiple overlapping thin slab acquisition techniques AJR Am J Roentgenol 163 4 915 920 1:STN:280:DyaK2cznvV2itQ%3D%3D 8092035
    • (1994) AJR Am J Roentgenol , vol.163 , Issue.4 , pp. 915-920
    • Davis, W.L.1    Blatter, D.D.2    Harnsberger, H.R.3    Parker, D.L.4
  • 16
    • 0029114625 scopus 로고
    • Magnetic resonance angiography of cerebral arteriovenous malformations
    • 1:STN:280:DyaK28%2Fls1Cmtg%3D%3D 10.2176/nmc.35.580
    • T Abe K Matsumoto Y Horichi T Hayashi H Ikeda T Iwata 1995 Magnetic resonance angiography of cerebral arteriovenous malformations Neurol Med Chir 35 8 580 583 1:STN:280:DyaK28%2Fls1Cmtg%3D%3D 10.2176/nmc.35.580
    • (1995) Neurol Med Chir , vol.35 , Issue.8 , pp. 580-583
    • Abe, T.1    Matsumoto, K.2    Horichi, Y.3    Hayashi, T.4    Ikeda, H.5    Iwata, T.6
  • 17
    • 0034752732 scopus 로고    scopus 로고
    • High-resolution intracranial and cervical MRA at 3.0T: Technical considerations and initial experience
    • DOI 10.1002/mrm.1282
    • MA Bernstein J Huston 3rd C Lin GF Gibbs JP Felmlee 2001 High-resolution intracranial and cervical MRA at 3.0 T: technical considerations and initial experience Magn Reson Med 46 5 955 962 1:STN:280:DC%2BD3MrmvVGhsg%3D%3D 10.1002/mrm.1282 11675648 (Pubitemid 33019920)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.5 , pp. 955-962
    • Bernstein, M.A.1    Huston III, J.2    Lin, C.3    Gibbs, G.F.4    Felmlee, J.P.5
  • 18
    • 0242439328 scopus 로고    scopus 로고
    • Principles and applications of balanced SSFP techniques
    • DOI 10.1007/s00330-003-1957-x
    • K Scheffler S Lehnhardt 2003 Principles and applications of balanced SSFP techniques Eur Radiol 13 11 2409 2418 10.1007/s00330-003-1957-x 12928954 (Pubitemid 37407471)
    • (2003) European Radiology , vol.13 , Issue.11 , pp. 2409-2418
    • Scheffler, K.1    Lehnhardt, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.