메뉴 건너뛰기




Volumn 65, Issue 2, 2011, Pages 399-408

Flip-angle measurement by magnetization inversion: Calibration of magnetization nutation angle in hyperpolarized 3He magnetic resonance imaging lung experiments

Author keywords

calibration; magnetization; modulation; MRI

Indexed keywords

ANGLE MEASUREMENT; CALIBRATION; MAGNETIC RESONANCE IMAGING; MODULATION; RESONANCE;

EID: 79251558452     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22638     Document Type: Article
Times cited : (5)

References (25)
  • 1
    • 0344980295 scopus 로고    scopus 로고
    • Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: Diffusion coefficient
    • Chen XJ, Moller HE, Chawla MS, Cofer GP, Driehuys B, Hedlund LW, Johnson GA,. Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: diffusion coefficient. Magn Reson Med 1999; 42: 721-728.
    • (1999) Magn Reson Med , vol.42 , pp. 721-728
    • Chen, X.J.1    Moller, H.E.2    Chawla, M.S.3    Cofer, G.P.4    Driehuys, B.5    Hedlund, L.W.6    Johnson, G.A.7
  • 4
    • 0031629304 scopus 로고    scopus 로고
    • MRI using hyperpolarized noble gases
    • Kauczor H, Surkau R, Roberts T,. MRI using hyperpolarized noble gases. Eur Radiol 1998; 8: 820-827.
    • (1998) Eur Radiol , vol.8 , pp. 820-827
    • Kauczor, H.1    Surkau, R.2    Roberts, T.3
  • 8
    • 33646455297 scopus 로고    scopus 로고
    • Advantages of parallel imaging in conjunction with hyperpolarized helium-a new approach to MRI of the lung
    • Lee RF, Johnson G, Grossman RI, Stoeckel B, Trampel R, McGuinness G,. Advantages of parallel imaging in conjunction with hyperpolarized helium-a new approach to MRI of the lung. Magn Reson Med 2006; 55: 1132-1141.
    • (2006) Magn Reson Med , vol.55 , pp. 1132-1141
    • Lee, R.F.1    Johnson, G.2    Grossman, R.I.3    Stoeckel, B.4    Trampel, R.5    McGuinness, G.6
  • 9
    • 0030066913 scopus 로고    scopus 로고
    • Calibration of the radio frequency field for magnetic resonance imaging
    • Foxall DL, Hoppel BE, Hariharan H,. Calibration of the radio frequency field for magnetic resonance imaging. Magn Reson Med 1996; 35: 229-236.
    • (1996) Magn Reson Med , vol.35 , pp. 229-236
    • Foxall, D.L.1    Hoppel, B.E.2    Hariharan, H.3
  • 10
    • 33845263696 scopus 로고    scopus 로고
    • Fast 3D radiofrequency field mapping using echo-planar imaging
    • Jiru F, Klose U,. Fast 3D radiofrequency field mapping using echo-planar imaging. Magn Reson Med 2006; 56: 1375-1379.
    • (2006) Magn Reson Med , vol.56 , pp. 1375-1379
    • Jiru, F.1    Klose, U.2
  • 11
    • 0034900050 scopus 로고    scopus 로고
    • Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties
    • Alecci M, Collins CM, Smith MB, Jezzard P,. Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: experimental and theoretical dependence on sample properties. Magn Reson Med 2001; 46: 379-385.
    • (2001) Magn Reson Med , vol.46 , pp. 379-385
    • Alecci, M.1    Collins, C.M.2    Smith, M.B.3    Jezzard, P.4
  • 13
    • 33846078031 scopus 로고    scopus 로고
    • Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
    • Yarnykh VL,. Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn Reson Med 2007; 57: 192-200.
    • (2007) Magn Reson Med , vol.57 , pp. 192-200
    • Yarnykh, V.L.1
  • 14
    • 0025160242 scopus 로고
    • Rapid radiofrequency calibration in MRI
    • Carlson JW, Kramer DM,. Rapid radiofrequency calibration in MRI. Magn Reson Med 1990; 15: 438-445.
    • (1990) Magn Reson Med , vol.15 , pp. 438-445
    • Carlson, J.W.1    Kramer, D.M.2
  • 17
    • 33947600713 scopus 로고    scopus 로고
    • Radiation-damping effects in a birdcage resonator with hyperpolarised 3He gas NMR at 1.5 T
    • Teh K, de Zanche N, Wild JM,. Radiation-damping effects in a birdcage resonator with hyperpolarised 3He gas NMR at 1.5 T. J Magn Reson 2007; 185: 164-172.
    • (2007) J Magn Reson , vol.185 , pp. 164-172
    • Teh, K.1    De Zanche, N.2    Wild, J.M.3
  • 18
    • 0024318208 scopus 로고
    • MR imaging of motion with spatial modulation of magnetization
    • Axel L, Dougherty L,. MR imaging of motion with spatial modulation of magnetization. Radiology 1989; 171: 841-845.
    • (1989) Radiology , vol.171 , pp. 841-845
    • Axel, L.1    Dougherty, L.2
  • 20
    • 0023737101 scopus 로고
    • Human heart: Tagging with MR imaging-a method for noninvasive assessment of myocardial motion
    • Zerhouni EA, Parish DM, Rogers WJ, Yang A, Shapiro EP,. Human heart: tagging with MR imaging-a method for noninvasive assessment of myocardial motion. Radiology 1988; 169: 59-63.
    • (1988) Radiology , vol.169 , pp. 59-63
    • Zerhouni, E.A.1    Parish, D.M.2    Rogers, W.J.3    Yang, A.4    Shapiro, E.P.5
  • 21
    • 2342588151 scopus 로고    scopus 로고
    • Magnetization tagging decay to measure long-range (3)He diffusion in healthy and emphysematous canine lungs
    • Woods JC, Yablonskiy DA, Chino K, Tanoli TS, Cooper JD, Conradi MS,. Magnetization tagging decay to measure long-range (3)He diffusion in healthy and emphysematous canine lungs. Magn Reson Med 2004; 51: 1002-1008.
    • (2004) Magn Reson Med , vol.51 , pp. 1002-1008
    • Woods, J.C.1    Yablonskiy, D.A.2    Chino, K.3    Tanoli, T.S.4    Cooper, J.D.5    Conradi, M.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.