메뉴 건너뛰기




Volumn 13, Issue 2, 2011, Pages 112-119

Influence of Sex on the Accuracy of Oscillometric-Derived Blood Pressures

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; AGE; AGED; ANGIOCARDIOGRAPHY; AORTA PRESSURE; ARTICLE; BLOOD PRESSURE MEASUREMENT; BODY MASS; BRACHIAL ARTERY; DEMOGRAPHY; DIABETES MELLITUS; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; GENDER; HEART RATE; HUMAN; HYPERTENSION; MAJOR CLINICAL STUDY; MALE; MEAN ARTERIAL PRESSURE; MULTIVARIATE LOGISTIC REGRESSION ANALYSIS; OSCILLOMETRY; PRIORITY JOURNAL; PULSE PRESSURE; RACE; SMOKING;

EID: 79251535929     PISSN: 15246175     EISSN: 17517176     Source Type: Journal    
DOI: 10.1111/j.1751-7176.2010.00391.x     Document Type: Article
Times cited : (9)

References (20)
  • 1
    • 34250875202 scopus 로고    scopus 로고
    • Central pressure more strongly relates to vascular disease and outcome than does brachial pressure: the Strong Heart Study
    • Roman MJ, Devereux RB, Kizer JR, et al. Central pressure more strongly relates to vascular disease and outcome than does brachial pressure: the Strong Heart Study. Hypertension. 2007;50:197-203.
    • (2007) Hypertension , vol.50 , pp. 197-203
    • Roman, M.J.1    Devereux, R.B.2    Kizer, J.R.3
  • 2
    • 34250862170 scopus 로고    scopus 로고
    • Central blood pressure measurements and antihypertensive therapy: a consensus document
    • Agabiti-Rosei E, Mancia G, O'Rourke MF, et al. Central blood pressure measurements and antihypertensive therapy: a consensus document. Hypertension. 2007;50:154-160.
    • (2007) Hypertension , vol.50 , pp. 154-160
    • Agabiti-Rosei, E.1    Mancia, G.2    O'Rourke, M.F.3
  • 3
    • 67649644424 scopus 로고    scopus 로고
    • Central aortic pressure and clinical outcomes
    • Williams B, Lacy PS. Central aortic pressure and clinical outcomes. J Hypertens. 2009;27:1123-1125.
    • (2009) J Hypertens , vol.27 , pp. 1123-1125
    • Williams, B.1    Lacy, P.S.2
  • 4
    • 42049122164 scopus 로고    scopus 로고
    • Pulsatile but not steady component of blood pressure predicts cardiovascular events in coronary patients
    • Jankowski P, Kawecka-Jaszcz K, Czarnecka D, et al. Pulsatile but not steady component of blood pressure predicts cardiovascular events in coronary patients. Hypertension. 2008;51:848-855.
    • (2008) Hypertension , vol.51 , pp. 848-855
    • Jankowski, P.1    Kawecka-Jaszcz, K.2    Czarnecka, D.3
  • 5
    • 38949124051 scopus 로고    scopus 로고
    • A preliminary evaluation of the mean arterial pressure as measured by cuff oscillometry
    • Smulyan H, Sheehe PR, Safar ME. A preliminary evaluation of the mean arterial pressure as measured by cuff oscillometry. Am J Hypertens. 2008;21:166-171.
    • (2008) Am J Hypertens , vol.21 , pp. 166-171
    • Smulyan, H.1    Sheehe, P.R.2    Safar, M.E.3
  • 6
    • 33645312386 scopus 로고    scopus 로고
    • Comparison of oscillometric and intraarterial systolic and diastolic blood pressures in lean, overweight, and obese patients
    • Umana E, Ahmed W, Fraley MA, et al. Comparison of oscillometric and intraarterial systolic and diastolic blood pressures in lean, overweight, and obese patients. Angiology. 2006;57:41-45.
    • (2006) Angiology , vol.57 , pp. 41-45
    • Umana, E.1    Ahmed, W.2    Fraley, M.A.3
  • 7
    • 0030762104 scopus 로고    scopus 로고
    • Influence of gender on the level of pulse pressure: the role of large conduit arteries
    • Asmar R, Brisac AM, Courivaud JM, et al. Influence of gender on the level of pulse pressure: the role of large conduit arteries. Clin Exp Hypertens. 1997;19:793-811.
    • (1997) Clin Exp Hypertens , vol.19 , pp. 793-811
    • Asmar, R.1    Brisac, A.M.2    Courivaud, J.M.3
  • 8
    • 0035212360 scopus 로고    scopus 로고
    • Gender differences in the timing of arterial wave reflection beyond differences in body height
    • Gatzka CD, Kingwell BA, Cameron JD, et al. Gender differences in the timing of arterial wave reflection beyond differences in body height. J Hypertens. 2001;19:2197-2203.
    • (2001) J Hypertens , vol.19 , pp. 2197-2203
    • Gatzka, C.D.1    Kingwell, B.A.2    Cameron, J.D.3
  • 9
    • 13444255966 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research
    • Pickering TG, Hall JE, Appel LJ, et al. Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Circulation. 2005;111:697-716.
    • (2005) Circulation , vol.111 , pp. 697-716
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3
  • 10
    • 0035992025 scopus 로고    scopus 로고
    • Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults
    • O'Brien E, Pickering T, Asmar R, et al. Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit. 2002;7:3-17.
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3
  • 11
    • 9644289535 scopus 로고    scopus 로고
    • Validation of a new formula for mean arterial pressure calculation: the new formula is superior to the standard formula
    • Razminia M, Trivedi A, Molnar J, et al. Validation of a new formula for mean arterial pressure calculation: the new formula is superior to the standard formula. Catheter Cardiovasc Interv. 2004;63:419-425.
    • (2004) Catheter Cardiovasc Interv , vol.63 , pp. 419-425
    • Razminia, M.1    Trivedi, A.2    Molnar, J.3
  • 12
    • 0027479012 scopus 로고
    • National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers
    • White WB, Berson AS, Robbins C, et al. National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers. Hypertension. 1993;21:504-509.
    • (1993) Hypertension , vol.21 , pp. 504-509
    • White, W.B.1    Berson, A.S.2    Robbins, C.3
  • 13
    • 68549098079 scopus 로고    scopus 로고
    • Amplification of the pressure pulse in the upper limb in healthy, middle-aged men and women
    • Segers P, Mahieu D, Kips J, et al. Amplification of the pressure pulse in the upper limb in healthy, middle-aged men and women. Hypertension. 2009;54:414-420.
    • (2009) Hypertension , vol.54 , pp. 414-420
    • Segers, P.1    Mahieu, D.2    Kips, J.3
  • 14
    • 0024440819 scopus 로고
    • Optimal size of cuff bladder for indirect measurement of arterial pressure in adults
    • Russell AE, Wing LM, Smith SA, et al. Optimal size of cuff bladder for indirect measurement of arterial pressure in adults. J Hypertens. 1989;7:607-613.
    • (1989) J Hypertens , vol.7 , pp. 607-613
    • Russell, A.E.1    Wing, L.M.2    Smith, S.A.3
  • 15
    • 0032522750 scopus 로고    scopus 로고
    • Comparative accuracy of three automated techniques in the noninvasive estimation of central blood pressure in men
    • Lehmann KG, Gelman JA, Weber MA, et al. Comparative accuracy of three automated techniques in the noninvasive estimation of central blood pressure in men. Am J Cardiol. 1998;81:1004-1012.
    • (1998) Am J Cardiol , vol.81 , pp. 1004-1012
    • Lehmann, K.G.1    Gelman, J.A.2    Weber, M.A.3
  • 16
    • 0020403175 scopus 로고
    • Noninvasive estimation of central aortic pressure using the oscillometric method for analyzing systemic artery pulsatile blood flow: comparative study of indirect systolic, diastolic, and mean brachial artery pressure with simultaneous direct ascending aortic pressure measurements
    • Borow KM, Newburger JW. Noninvasive estimation of central aortic pressure using the oscillometric method for analyzing systemic artery pulsatile blood flow: comparative study of indirect systolic, diastolic, and mean brachial artery pressure with simultaneous direct ascending aortic pressure measurements. Am Heart J. 1982;103:879-886.
    • (1982) Am Heart J , vol.103 , pp. 879-886
    • Borow, K.M.1    Newburger, J.W.2
  • 17
    • 0025008045 scopus 로고
    • Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations
    • Gravlee GP, Brockschmidt JK. Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations. J Clin Monit. 1990;6:284-298.
    • (1990) J Clin Monit , vol.6 , pp. 284-298
    • Gravlee, G.P.1    Brockschmidt, J.K.2
  • 18
    • 0030877937 scopus 로고    scopus 로고
    • Development and validation of a noninvasive method to determine arterial pressure and vascular compliance
    • Brinton TJ, Cotter B, Kailasam MT, et al. Development and validation of a noninvasive method to determine arterial pressure and vascular compliance. Am J Cardiol. 1997;80:323-330.
    • (1997) Am J Cardiol , vol.80 , pp. 323-330
    • Brinton, T.J.1    Cotter, B.2    Kailasam, M.T.3
  • 19
    • 0026062136 scopus 로고
    • Blood pressure monitoring: automated oscillometric devices
    • Ramsey M III. Blood pressure monitoring: automated oscillometric devices. J Clin Monit. 1991;7:56-67.
    • (1991) J Clin Monit , vol.7 , pp. 56-67
    • Ramsey III, M.1
  • 20
    • 0038460302 scopus 로고    scopus 로고
    • The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure: the JNC 7 report
    • Chobanian AV, Bakris GL, Black HR, et al. The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure: the JNC 7 report. JAMA. 2003;289:2560-2572.
    • (2003) JAMA , vol.289 , pp. 2560-2572
    • Chobanian, A.V.1    Bakris, G.L.2    Black, H.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.