Volumn 13, Issue 2, 2011, Pages 262-269

Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: Results from the PICTURE registry

(13)  Edvardsson, Nils a   Frykman, Viveka b   Van Mechelen, Rob c   Mitro, Peter d   Mohii Oskarsson, Afsaneh e   Pasqui, Jean Luc f   Ramanna, Hemanth g   Schwertfeger, Frank h   Ventura, Rodolfo i   Voulgaraki, Despina j   Garutti, Claudio j   Stolt, Pelle k   Linker, Nicholas J l  


Author keywords

Cardiac syncope; Guidelines; Implantable loop recorder; Injuries; Reveal; Traumas

Indexed keywords

ANTIARRHYTHMIC AGENT;

EID: 79251524247     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/euq418     Document Type: Article
Times cited : (208)

References (23)
  • 1
    • 33748078740 scopus 로고    scopus 로고
    • Vasovagal syncope in medical stu-dents and their first-degree relatives
    • Serletis A, Rose S, Sheldon AG, Sheldon RS. Vasovagal syncope in medical stu-dents and their first-degree relatives. Eur Heart J 2006;27:1965-70.
    • (2006) Eur Heart J , vol.27 , pp. 1965-70
    • Serletis, A.1    Rose, S.2    Sheldon, A.G.3    Sheldon, R.S.4
  • 3
    • 0036558578 scopus 로고    scopus 로고
    • Prospective evaluation and outcome of patients admitted for syncope over a 1 year period
    • Blanc JJ, L'Her C, Touiza A, Garo B, L'Her E, Mansourati J. Prospective evaluation and outcome of patients admitted for syncope over a 1 year period. Eur Heart J 2002;23:815-20.
    • (2002) Eur Heart J , vol.23 , pp. 815-20
    • Blanc, J.J.1    L'Her, C.2    Touiza, A.3    Garo, B.4    L'Her, E.5    Mansourati, J.6
  • 5
    • 0034537659 scopus 로고    scopus 로고
    • The relationship between health-related quality of life and the frequency of spells in patients with syncope
    • Rose MS, Koshman ML, Spreng S, Sheldon R. The relationship between health-related quality of life and the frequency of spells in patients with syncope.J Clin Epidemiol 2000;53:1209-16.
    • (2000) J Clin Epidemiol , vol.53 , pp. 1209-16
    • Rose, M.S.1    Koshman, M.L.2    Spreng, S.3    Sheldon, R.4
  • 8
    • 70449515360 scopus 로고    scopus 로고
    • Guidelines for the diagnosis and management of syncope (version 2009): The Task Force for the Diagnosis and Management of Syncope of the European Society of Cardiology (ESC)
    • Moya A, Sutton R, Ammirati F, Blanc JJ, Brignole M, Dahm JB et al. Guidelines for the diagnosis and management of syncope (version 2009): the Task Force for the Diagnosis and Management of Syncope of the European Society of Cardiology (ESC). Eur Heart J 2009;30:2631-71.
    • (2009) Eur Heart J , vol.30 , pp. 2631-71
    • Moya, A.1    Sutton, R.2    Ammirati, F.3    Blanc, J.J.4    Brignole, M.5    Dahm, J.B.6
  • 9
    • 66749119013 scopus 로고    scopus 로고
    • Indications for the use of diagnostic implantable and external ECG loop recorders
    • Brignole M, Vardas P, Hoffman E, Huikuri H, Moya A, Ricci R et al. Indications for the use of diagnostic implantable and external ECG loop recorders. Europace 2009;11:671-87.
    • (2009) Europace , vol.11 , pp. 671-87
    • Brignole, M.1    Vardas, P.2    Hoffman, E.3    Huikuri, H.4    Moya, A.5    Ricci, R.6
  • 10
    • 0003491133 scopus 로고    scopus 로고
    • World Medical Association Adopted by the 18th WMA General Assembly, Helsinki, Finland, June 1964, and amended by the 59th WMA General Assembly, Seoul, October 2008. 10 August 2010, date last accessed
    • World Medical Association. Declaration of Helsinki. Ethical Principles for Medical Research Involving Human Subjects. Adopted by the 18th WMA General Assembly, Helsinki, Finland,June 1964, and amended by the 59th WMA General Assembly, Seoul, October 2008. http://www.wma.net/en/30publications/10policies/ b3/index.html (10 August 2010, date last accessed).
    • Declaration of Helsinki. Ethical Principles for Medical Research Involving Human Subjects
  • 12
    • 3042756574 scopus 로고    scopus 로고
    • Use of implantable loop recorders in the diagnosis and management of syncope
    • Farwell DJ, Freemantle N, Sulke AN. Use of implantable loop recorders in the diagnosis and management of syncope. Eur Heart J 2004;25:1257-63.
    • (2004) Eur Heart J , vol.25 , pp. 1257-63
    • Farwell, D.J.1    Freemantle, N.2    Sulke, A.N.3
  • 13
    • 28944443270 scopus 로고    scopus 로고
    • A new man-agement of syncope: Prospective systematic guideline-based evaluation of patients referred urgently to general hospitals
    • Brignole M, Menozzi C, Bartoletti A, Giada F, Lagi A, Ungar A et al. A new man-agement of syncope: prospective systematic guideline-based evaluation of patients referred urgently to general hospitals. Eur Heart J 2006;27:76-82.
    • (2006) Eur Heart J , vol.27 , pp. 76-82
    • Brignole, M.1    Menozzi, C.2    Bartoletti, A.3    Giada, F.4    Lagi, A.5    Ungar, A.6
  • 14
    • 33646264814 scopus 로고    scopus 로고
    • Early application of an implantable loop recorder allows effective specific therapy in patients with recurrent suspected neurally mediated syncope
    • International Study on Syncope of Uncertain Etiology 2 (ISSUE 2) Group
    • Brignole M, Sutton R, Menozzi C, Garcia-Civera R, Moya A, Wieling W et al. International Study on Syncope of Uncertain Etiology 2 (ISSUE 2) Group. Early application of an implantable loop recorder allows effective specific therapy in patients with recurrent suspected neurally mediated syncope. Eur Heart J 2006; 27:1085-92.
    • (2006) Eur Heart J , vol.27 , pp. 1085-92
    • Brignole, M.1    Sutton, R.2    Menozzi, C.3    Garcia-Civera, R.4    Moya, A.5    Wieling, W.6
  • 15
    • 48049122247 scopus 로고    scopus 로고
    • Physical injuries caused by a transient loss of consciousness: Main clinical charac-teristics of patients and diagnostic contribution of carotid sinus massage
    • Bartoletti A, Fabiani P, Bagnoli L, Cappelletti C, Cappellini M, Nappini G et al. Physical injuries caused by a transient loss of consciousness: main clinical charac-teristics of patients and diagnostic contribution of carotid sinus massage. Eur Heart J 2008;29:618-24.
    • (2008) Eur Heart J , vol.29 , pp. 618-24
    • Bartoletti, A.1    Fabiani, P.2    Bagnoli, L.3    Cappelletti, C.4    Cappellini, M.5    Nappini, G.6
  • 16
    • 0346059364 scopus 로고    scopus 로고
    • Does the use of a syncope diagnostic protocol improve the investigation and management of syncope?
    • Farwell DJ, Sulke AN. Does the use of a syncope diagnostic protocol improve the investigation and management of syncope? Heart 2004;90:52-8.
    • (2004) Heart , vol.90 , pp. 52-8
    • Farwell, D.J.1    Sulke, A.N.2
  • 17
    • 33748089358 scopus 로고    scopus 로고
    • Standardized-care pathway vs. usual management of syncope patients presenting as emergen-cies at general hospitals
    • Brignole M, Ungar A, Bartoletti A, Ponassi I, Lagi A, Mussi C et al. Standardized-care pathway vs. usual management of syncope patients presenting as emergen-cies at general hospitals. Europace 2006;8:644-50.
    • (2006) Europace , vol.8 , pp. 644-50
    • Brignole, M.1    Ungar, A.2    Bartoletti, A.3    Ponassi, I.4    Lagi, A.5    Mussi, C.6
  • 19
    • 12544257274 scopus 로고    scopus 로고
    • Utility of implantable loop recorder (Reveal Plus) in the diagnosis of unexplained syncope
    • Lombardi F, Calosso E, Mascioli G, Marangoni E, Donato A, Rossi S et al. Utility of implantable loop recorder (Reveal Plus) in the diagnosis of unexplained syncope. Europace 2005;7:19-24.
    • (2005) Europace , vol.7 , pp. 19-24
    • Lombardi, F.1    Calosso, E.2    Mascioli, G.3    Marangoni, E.4    Donato, A.5    Rossi, S.6
  • 20
    • 4143058092 scopus 로고    scopus 로고
    • Skanes AC Detection of asymptomatic arrhythmias in unexplained syncope
    • Krahn AD, Klein GJ, Yee R, Skanes AC Detection of asymptomatic arrhythmias in unexplained syncope. Am Heart J 2004;148:326-32.
    • (2004) Am Heart J , vol.148 , pp. 326-32
    • Krahn, A.D.1    Klein, G.J.2    Yee, R.3
  • 21
    • 3042586620 scopus 로고    scopus 로고
    • Incidence, diag-nostic yield and safety of the implantable loop-recorder to detect the mechanism of syncope in patients with and without structural heart disease
    • Solano A, Menozzi C, Maggi R, Donateo P, Bottoni N, Lolli G et al. Incidence, diag-nostic yield and safety of the implantable loop-recorder to detect the mechanism of syncope in patients with and without structural heart disease. Eur Heart J 2004; 25:1116-9.
    • (2004) Eur Heart J , vol.25 , pp. 1116-9
    • Solano, A.1    Menozzi, C.2    Maggi, R.3    Donateo, P.4    Bottoni, N.5    Lolli, G.6
  • 22
    • 0029120382 scopus 로고
    • The etiology of syncope in patients with negative tilt table and electrophysiological testing
    • Krahn AD, Klein GJ, Norris C, Yee R. The etiology of syncope in patients with negative tilt table and electrophysiological testing. Circulation 1995;92:1819-24.
    • (1995) Circulation , vol.92 , pp. 1819-24
    • Krahn, A.D.1    Klein, G.J.2    Norris, C.3    Yee, R.4
  • 23
    • 30744432342 scopus 로고    scopus 로고
    • The clinical impact of implantable loop recor-ders in patients with syncope
    • Farwell DJ, Freemantle N, Sulke N. The clinical impact of implantable loop recor-ders in patients with syncope. Eur Heart J 2006;27:351-6.
    • (2006) Eur Heart J , vol.27 , pp. 351-6
    • Farwell, D.J.1    Freemantle, N.2    Sulke, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.