-
1
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
2
-
-
0022796639
-
History of blood gas analysis VI. Oximetry
-
Severnghaus JW, Astrup PB. History of blood gas analysis VI. Oximetry. J Clin Monit 1986;2:270-88.
-
(1986)
J Clin Monit
, vol.2
, pp. 270-288
-
-
Severnghaus, J.W.1
Astrup, P.B.2
-
3
-
-
0042864457
-
Noninvasive respiratory monitoring equipment
-
In: Branson RD, Hess DR, Chatburn RL, editors, Philadelphia: JP Lippincott
-
Hess DR, Branson RD. Noninvasive respiratory monitoring equipment. In: Branson RD, Hess DR, Chatburn RL, editors. Respiratory care equipment. Philadelphia: JP Lippincott; 1995. p. 193.
-
(1995)
Respiratory care equipment
, pp. 193
-
-
Hess, D.R.1
Branson, R.D.2
-
5
-
-
16544384530
-
Pulse oximetry in children with congenital heart disease: Effects of cardiopulmonary bypass and cyanosis
-
Torres A Jr, Skender KM, Wohrley JD, Aldag JC, Raff GW, Bysani GK, et al. Pulse oximetry in children with congenital heart disease: Effects of cardiopulmonary bypass and cyanosis. J Intensive Care Med 2004;19:229-34.
-
(2004)
J Intensive Care Med
, vol.19
, pp. 229-234
-
-
Torres Jr., A.1
Skender, K.M.2
Wohrley, J.D.3
Aldag, J.C.4
Raff, G.W.5
Bysani, G.K.6
-
7
-
-
0031800328
-
Accuracy of two pulse oximeters at low arterial hemoglobinoxygen saturation
-
Carter BG, Carlin JB, Tibballs J, Mead H, Hochmann M, Osborne A. Accuracy of two pulse oximeters at low arterial hemoglobinoxygen saturation. Crit Care Med 1998;26:1128-133.
-
(1998)
Crit Care Med
, vol.26
, pp. 1128-1133
-
-
Carter, B.G.1
Carlin, J.B.2
Tibballs, J.3
Mead, H.4
Hochmann, M.5
Osborne, A.6
-
8
-
-
0026065614
-
Pulse oximeter sensors: A comparison between finger, nose, ear, and forehead sensors under conditions of poor perfusion
-
Clayton D, Webb RK, Ralston AC, Duthie D, Runciman WB. Pulse oximeter sensors: a comparison between finger, nose, ear, and forehead sensors under conditions of poor perfusion. Anaesthesia 1991;46:260-5.
-
(1991)
Anaesthesia
, vol.46
, pp. 260-265
-
-
Clayton, D.1
Webb, R.K.2
Ralston, A.C.3
Duthie, D.4
Runciman, W.B.5
-
9
-
-
0032840223
-
Effect of sensor design on accuracy and reliability of pulse oximetry in pediatric patients
-
Bell C, Luther MA, Nicholson J, Fox CJ, Hirsh JL. Effect of sensor design on accuracy and reliability of pulse oximetry in pediatric patients. J Clin Anesth 1999;11:323-7.
-
(1999)
J Clin Anesth
, vol.11
, pp. 323-327
-
-
Bell, C.1
Luther, M.A.2
Nicholson, J.3
Fox, C.J.4
Hirsh, J.L.5
-
10
-
-
0030989206
-
Effects of motion, ambient light, and hypoperfusion on pulse oximeter function
-
Trivedi NS, Ghouri AF, Shah NK, Lai E, Barker SJ. Effects of motion, ambient light, and hypoperfusion on pulse oximeter function. J Clin Anesth 1997;9:179-83.
-
(1997)
J Clin Anesth
, vol.9
, pp. 179-183
-
-
Trivedi, N.S.1
Ghouri, A.F.2
Shah, N.K.3
Lai, E.4
Barker, S.J.5
-
11
-
-
0026328123
-
Reliability of noninvasive oximetry in black subjects during exercise and hypoxia
-
Zeballos RJ, Weisman IM. Reliability of noninvasive oximetry in black subjects during exercise and hypoxia. Am Rev Respir Dis 1991;144:1240-4.
-
(1991)
Am Rev Respir Dis
, vol.144
, pp. 1240-1244
-
-
Zeballos, R.J.1
Weisman, I.M.2
-
12
-
-
0032867708
-
Effect of peripheral perfusion on accuracy of pulse oximetry in children
-
Villanueva R, Bell C, Kain ZN, Colingo KA. Effect of peripheral perfusion on accuracy of pulse oximetry in children. J Clin Anest h 1999;11:317-22.
-
(1999)
J Clin Anest h
, vol.11
, pp. 317-322
-
-
Villanueva, R.1
Bell, C.2
Kain, Z.N.3
Colingo, K.A.4
-
13
-
-
0025375813
-
An in vitro model for evaluating the accuracy of pulse oximeters
-
Volgyesi GA, Kolesar R, Lerman J. An in vitro model for evaluating the accuracy of pulse oximeters. Can J Anaesth 1990;37:S67.
-
(1990)
Can J Anaesth
, vol.37
-
-
Volgyesi, G.A.1
Kolesar, R.2
Lerman, J.3
-
14
-
-
0025297647
-
Effect of haemoglobin concentration on the accuracy of pulse oximetry
-
Kolesar R, Volgyesi G, Lerman J. Effect of haemoglobin concentration on the accuracy of pulse oximetry. Can J Anaesth 1990;37:S88.
-
(1990)
Can J Anaesth
, vol.37
-
-
Kolesar, R.1
Volgyesi, G.2
Lerman, J.3
-
16
-
-
0023968368
-
Bias and precision of pulse oximeters and arterial oximeters
-
Nickerson BG, Sarkisian C, Tremper KK. Bias and precision of pulse oximeters and arterial oximeters. Chest 1988;93:515-7.
-
(1988)
Chest
, vol.93
, pp. 515-517
-
-
Nickerson, B.G.1
Sarkisian, C.2
Tremper, K.K.3
-
17
-
-
0024614115
-
A comparison of fifteen pulse oximeters. Part I: A clinical comparison; Part II: A test of performance under conditions of poor perfusion
-
Morris RW, Nairn M, Torda TA. A comparison of fifteen pulse oximeters. Part I: a clinical comparison; Part II: a test of performance under conditions of poor perfusion. Anaesth Intensive Care 1989;17:62-82.
-
(1989)
Anaesth Intensive Care
, vol.17
, pp. 62-82
-
-
Morris, R.W.1
Nairn, M.2
Torda, T.A.3
-
18
-
-
0024678932
-
-
Emergency Care Research Institute: Pulse oximeters
-
Emergency Care Research Institute: Pulse oximeters. Health Devices 1989;18:185-230.
-
(1989)
Health Devices
, vol.18
, pp. 185-230
-
-
|