Volumn 54, Issue 6, 2010, Pages 531-534

Pulse oximeter accuracy and precision at fifi ve different sensor locations in infants and children with cyanotic heart disease

Author keywords

Accuracy; Bias; Co oximeter; Precision; Pulse oximetry; SaO2; SpO2

Indexed keywords

ACCURACY; ARTERIAL GAS; ARTERIAL OXYGEN SATURATION; ARTICLE; CHILD; CLINICAL ARTICLE; CYANOTIC HEART DISEASE; FALLOT TETRALOGY; FINGER; GREAT VESSELS TRANSPOSITION; HEART RATE; HEART RIGHT VENTRICLE DOUBLE OUTLET; HUMAN; INFANT; OBSERVATIONAL STUDY; OXYGEN SATURATION; PRESCHOOL CHILD; PULSE OXIMETER; SCHOOL CHILD; SENSOR; TOE;

EID: 79251498967     PISSN: 00195049     EISSN: None     Source Type: Journal    
DOI: 10.4103/0019-5049.72642     Document Type: Article
Times cited : (21)

References (18)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 2
    • 0022796639 scopus 로고
    • History of blood gas analysis VI. Oximetry
    • Severnghaus JW, Astrup PB. History of blood gas analysis VI. Oximetry. J Clin Monit 1986;2:270-88.
    • (1986) J Clin Monit , vol.2 , pp. 270-288
    • Severnghaus, J.W.1    Astrup, P.B.2
  • 3
    • 0042864457 scopus 로고
    • Noninvasive respiratory monitoring equipment
    • In: Branson RD, Hess DR, Chatburn RL, editors, Philadelphia: JP Lippincott
    • Hess DR, Branson RD. Noninvasive respiratory monitoring equipment. In: Branson RD, Hess DR, Chatburn RL, editors. Respiratory care equipment. Philadelphia: JP Lippincott; 1995. p. 193.
    • (1995) Respiratory care equipment , pp. 193
    • Hess, D.R.1    Branson, R.D.2
  • 8
    • 0026065614 scopus 로고
    • Pulse oximeter sensors: A comparison between finger, nose, ear, and forehead sensors under conditions of poor perfusion
    • Clayton D, Webb RK, Ralston AC, Duthie D, Runciman WB. Pulse oximeter sensors: a comparison between finger, nose, ear, and forehead sensors under conditions of poor perfusion. Anaesthesia 1991;46:260-5.
    • (1991) Anaesthesia , vol.46 , pp. 260-265
    • Clayton, D.1    Webb, R.K.2    Ralston, A.C.3    Duthie, D.4    Runciman, W.B.5
  • 9
    • 0032840223 scopus 로고    scopus 로고
    • Effect of sensor design on accuracy and reliability of pulse oximetry in pediatric patients
    • Bell C, Luther MA, Nicholson J, Fox CJ, Hirsh JL. Effect of sensor design on accuracy and reliability of pulse oximetry in pediatric patients. J Clin Anesth 1999;11:323-7.
    • (1999) J Clin Anesth , vol.11 , pp. 323-327
    • Bell, C.1    Luther, M.A.2    Nicholson, J.3    Fox, C.J.4    Hirsh, J.L.5
  • 10
    • 0030989206 scopus 로고    scopus 로고
    • Effects of motion, ambient light, and hypoperfusion on pulse oximeter function
    • Trivedi NS, Ghouri AF, Shah NK, Lai E, Barker SJ. Effects of motion, ambient light, and hypoperfusion on pulse oximeter function. J Clin Anesth 1997;9:179-83.
    • (1997) J Clin Anesth , vol.9 , pp. 179-183
    • Trivedi, N.S.1    Ghouri, A.F.2    Shah, N.K.3    Lai, E.4    Barker, S.J.5
  • 11
    • 0026328123 scopus 로고
    • Reliability of noninvasive oximetry in black subjects during exercise and hypoxia
    • Zeballos RJ, Weisman IM. Reliability of noninvasive oximetry in black subjects during exercise and hypoxia. Am Rev Respir Dis 1991;144:1240-4.
    • (1991) Am Rev Respir Dis , vol.144 , pp. 1240-1244
    • Zeballos, R.J.1    Weisman, I.M.2
  • 12
    • 0032867708 scopus 로고    scopus 로고
    • Effect of peripheral perfusion on accuracy of pulse oximetry in children
    • Villanueva R, Bell C, Kain ZN, Colingo KA. Effect of peripheral perfusion on accuracy of pulse oximetry in children. J Clin Anest h 1999;11:317-22.
    • (1999) J Clin Anest h , vol.11 , pp. 317-322
    • Villanueva, R.1    Bell, C.2    Kain, Z.N.3    Colingo, K.A.4
  • 13
    • 0025375813 scopus 로고
    • An in vitro model for evaluating the accuracy of pulse oximeters
    • Volgyesi GA, Kolesar R, Lerman J. An in vitro model for evaluating the accuracy of pulse oximeters. Can J Anaesth 1990;37:S67.
    • (1990) Can J Anaesth , vol.37
    • Volgyesi, G.A.1    Kolesar, R.2    Lerman, J.3
  • 14
    • 0025297647 scopus 로고
    • Effect of haemoglobin concentration on the accuracy of pulse oximetry
    • Kolesar R, Volgyesi G, Lerman J. Effect of haemoglobin concentration on the accuracy of pulse oximetry. Can J Anaesth 1990;37:S88.
    • (1990) Can J Anaesth , vol.37
    • Kolesar, R.1    Volgyesi, G.2    Lerman, J.3
  • 15
    • 61749100321 scopus 로고    scopus 로고
    • Pulse oximeter accuracy and precision affected by sensor location in cyanotic children
    • Sedaghat-Yazdi F, Torres A Jr, Fortuna R, Geiss DM. Pulse oximeter accuracy and precision affected by sensor location in cyanotic children. Pediatr Crit Care Med 2008;9:393-7.
    • (2008) Pediatr Crit Care Med , vol.9 , pp. 393-397
    • Sedaghat-Yazdi, F.1    Torres Jr., A.2    Fortuna, R.3    Geiss, D.M.4
  • 16
    • 0023968368 scopus 로고
    • Bias and precision of pulse oximeters and arterial oximeters
    • Nickerson BG, Sarkisian C, Tremper KK. Bias and precision of pulse oximeters and arterial oximeters. Chest 1988;93:515-7.
    • (1988) Chest , vol.93 , pp. 515-517
    • Nickerson, B.G.1    Sarkisian, C.2    Tremper, K.K.3
  • 17
    • 0024614115 scopus 로고
    • A comparison of fifteen pulse oximeters. Part I: A clinical comparison; Part II: A test of performance under conditions of poor perfusion
    • Morris RW, Nairn M, Torda TA. A comparison of fifteen pulse oximeters. Part I: a clinical comparison; Part II: a test of performance under conditions of poor perfusion. Anaesth Intensive Care 1989;17:62-82.
    • (1989) Anaesth Intensive Care , vol.17 , pp. 62-82
    • Morris, R.W.1    Nairn, M.2    Torda, T.A.3
  • 18
    • 0024678932 scopus 로고
    • Emergency Care Research Institute: Pulse oximeters
    • Emergency Care Research Institute: Pulse oximeters. Health Devices 1989;18:185-230.
    • (1989) Health Devices , vol.18 , pp. 185-230


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.