Volumn 25, Issue 1-3, 2011, Pages 226-232

Biological nitrogen removal at low water temperatures - long term experience

Author keywords

Low water temperature; Nitrogen removal; SBR; Solids retention time

Indexed keywords


EID: 79251475574     PISSN: 19443994     EISSN: 19443986     Source Type: Journal    
DOI: 10.5004/dwt.2011.1928     Document Type: Article
Times cited : (8)

References (19)
  • 3
    • 0028378529 scopus 로고
    • Biological phosphorus removal at temperatures from 3 to 10°C - a full scale study of a sequencing batch reactor unit
    • S. Marklund and S. Morling, Biological phosphorus removal at temperatures from 3 to 10°C - a full scale study of a sequencing batch reactor unit, Canad. J. Civil Eng., 21 (1994) 81-88
    • (1994) Canad. J. Civil Eng , vol.21 , pp. 81-88
    • Marklund, S.1    Morling, S.2
  • 4
    • 84900673804 scopus 로고    scopus 로고
    • Performance of an SBR plant in Ölmanäs, Sweden
    • S. Morling and A. Nyberg, Performance of an SBR plant in Ölmanäs, Sweden; Vatten, 52(1) (1996) 113-118.
    • (1996) Vatten , vol.52 , Issue.1 , pp. 113-118
    • Morling, S.1    Nyberg, A.2
  • 5
    • 84900584444 scopus 로고    scopus 로고
    • Betriebserfahrungen mit einer SBR - Anlage für 45000EG
    • S. Morling and G. Nyhuis, Betriebserfahrungen mit einer SBR - Anlage für 45000EG, Abwasser, 4 (1996) 541-544.
    • (1996) Abwasser , vol.4 , pp. 541-544
    • Morling, S.1    Nyhuis, G.2
  • 6
    • 79251489341 scopus 로고    scopus 로고
    • Integration of a Constructed Wetland Into a Modernised Wastewater Treatment Scheme: Options, Limitations and Results
    • Bulgaria
    • A. Franquiz and S. Morling, Integration of a constructed wetland into a modernised wastewater treatment scheme: Options, limitations and results. Proc. International Conference in Sofia, Bulgaria, 2006.
    • (2006) Proc. International Conference in Sofia
    • Franquiz, A.1    Morling, S.2
  • 7
    • 84900623471 scopus 로고    scopus 로고
    • Nitrogen removal efficiency and nitrification rates atthe sequencing batch reactor in Nowy Targ, Poland
    • S. Morling, Nitrogen removal efficiency and nitrification rates atthe sequencing batch reactor in Nowy Targ, Poland; VATTEN, 2 (2008) 121-128.
    • (2008) VATTEN , vol.2 , pp. 121-128
    • Morling, S.1
  • 10
    • 0031792232 scopus 로고    scopus 로고
    • Strategies for improvement of sludge quality and process performance of SBR plant treating municipal and tannery wastewater
    • M. Kabacinski, B. Hultman, E. Plaza and J. Trela, Strategies for improvement of sludge quality and process performance of SBR plant treating municipal and tannery wastewater. Wat. Sci Technol., 38(4-5) (1998) 69-77.
    • (1998) Wat. Sci Technol , vol.38 , Issue.5 , pp. 69-77
    • Kabacinski, M.1    Hultman, B.2    Plaza, E.3    Trela, J.4
  • 12
    • 0032881777 scopus 로고    scopus 로고
    • SBR technology used for advanced combined municipal and tannery wastewater treatment at high receiving water standards
    • J. Banaš, E. Płaza, W. Styka and J. Trela, SBR technology used for advanced combined municipal and tannery wastewater treatment at high receiving water standards. Wat. Sci. Technol., 40(4-5) (1999) 451-458.
    • (1999) Wat. Sci. Technol , vol.40 , Issue.5 , pp. 451-458
    • Banaš, J.1    Płaza, E.2    Styka, W.3    Trela, J.4
  • 14
    • 0035084112 scopus 로고    scopus 로고
    • Use of computer simulation for cycle length adjustment in sequencing batch reactor
    • J. Mikosz, E. Plaza and J. Kurbiel, Use of computer simulation for cycle length adjustment in sequencing batch reactor. Wat. Sci. Technol., 43(3) (2001) 61-68.
    • (2001) Wat. Sci. Technol , vol.43 , Issue.3 , pp. 61-68
    • Mikosz, J.1    Plaza, E.2    Kurbiel, J.3
  • 15
    • 79251491243 scopus 로고    scopus 로고
    • Plant Performance of An Sequencing Batch Reactor In Poland, Operated With High Chromium Load, Reaching Advanced Nutrient Removal
    • Vienna, September
    • S. Morling, Plant performance of an sequencing batch reactor in Poland, operated with high chromium load, reaching advanced nutrient removal, Proc. 10th IWA Specialised Conference on Large Wastewater Treatment Plants, Vienna, September 2007, pp. 227-234.
    • (2007) Proc. 10th IWA Specialised Conference on Large Wastewater Treatment Plants , pp. 227-234
    • Morling, S.1
  • 18