메뉴 건너뛰기




Volumn 36, Issue 15, 2003, Pages 23-27

Hip joint modeling for the control of the joint center and the range of motions

Author keywords

Computer aided diagnosis; Kinematic control system; Medical application; Model based control; Preoperative planning

Indexed keywords

COMPUTER AIDED DIAGNOSIS; HIP PROSTHESES; MEDICAL APPLICATIONS;

EID: 79251474143     PISSN: 14746670     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1016/S1474-6670(17)33466-3     Document Type: Conference Paper
Times cited : (12)

References (17)
  • 1
    • 0025353537 scopus 로고
    • A comparison of the accuracy of several hip center location prediction methods
    • Bell A. L., Petersen D. R., Brand R. A. (1990). A comparison of the accuracy of several hip center location prediction methods. Journal of Biomechanics Vol. 23, pp 617-621.
    • (1990) Journal of Biomechanics , vol.23 , pp. 617-621
    • Bell, A.L.1    Petersen, D.R.2    Brand, R.A.3
  • 3
    • 0021200788 scopus 로고
    • Gait analysis methodology
    • Cappozzo A. (1984). Gait analysis methodology, Human Movement Science 3, pp 27-54.
    • (1984) Human Movement Science , vol.3 , pp. 27-54
    • Cappozzo, A.1
  • 5
    • 0034023064 scopus 로고    scopus 로고
    • The influence of the acetabular labrum on hip joint cartilage consolidation: A poroelastic finite element model
    • Ferguson S. J., Bryant J. T., Ganz R., Ito K., (2000). The influence of the acetabular labrum on hip joint cartilage consolidation: a poroelastic finite element model, Journal of Biomechanics Vol. 33. pp 953-960.
    • (2000) Journal of Biomechanics , vol.33 , pp. 953-960
    • Ferguson, S.J.1    Bryant, J.T.2    Ganz, R.3    Ito, K.4
  • 6
    • 0019929394 scopus 로고
    • Congenital dislocation of the hip. Review at maturity of 147 hips treated by excision of the limbus and derotation osteotomy
    • Gibson PH., Benson M. K. (1982). Congenital dislocation of the hip. Review at maturity of 147 hips treated by excision of the limbus and derotation osteotomy. Journal of Bone and Joint Surgery 64-B, pp 169-175.
    • (1982) Journal of Bone and Joint Surgery , vol.64 B , pp. 169-175
    • Gibson, P.H.1    Benson, M.K.2
  • 7
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
    • Grood E. S., Suntay W. J. (1983). A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. Journal of Biomechanical Engineering Vol. 105, pp 136-144.
    • (1983) Journal of Biomechanical Engineering , vol.105 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 10
    • 0033060061 scopus 로고    scopus 로고
    • Radiographic and non-invasive determination of the hip joint centre location: Effect on hip joint moments
    • Kirkwood R. N., Culham E. G., Costigan P. (1999). Radiographic and non-invasive determination of the hip joint centre location: effect on hip joint moments, Clinical Biomechanics Vol. 14, pp 227-235.
    • (1999) Clinical Biomechanics , vol.14 , pp. 227-235
    • Kirkwood, R.N.1    Culham, E.G.2    Costigan, P.3
  • 13
    • 0002670706 scopus 로고
    • The role of hip arthroscopy in the diagnosis and treatment of hip disease
    • McCarthy J. C., Busconi B. (1995). The role of hip arthroscopy in the diagnosis and treatment of hip disease, Canadian Journal of Surgery Vol. 38 (Suppl. 1), pp S13-17.
    • (1995) Canadian Journal of Surgery , vol.38 , pp. S13-S17
    • McCarthy, J.C.1    Busconi, B.2
  • 14
    • 0031239970 scopus 로고    scopus 로고
    • The hip joint as a conchoid shape
    • Menschik F. (1997). The hip joint as a conchoid shape, Journal of Biomechanics, Vol. 30, No. 9, pp 971-973.
    • (1997) Journal of Biomechanics , vol.30 , Issue.9 , pp. 971-973
    • Menschik, F.1
  • 15
    • 0034984129 scopus 로고    scopus 로고
    • Accuracy of the functional method of hip joint center location: Effects of limited motion and varied implementation
    • Piazza S. J., Okita N., Cavanagh P. R. (2001). Accuracy of the functional method of hip joint center location: effects of limited motion and varied implementation, Journal of Biomechanics Vol. 34, pp 967-973.
    • (2001) Journal of Biomechanics , vol.34 , pp. 967-973
    • Piazza, S.J.1    Okita, N.2    Cavanagh, P.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.