메뉴 건너뛰기




Volumn 26, Issue 1, 2011, Pages 14-19

Reliability and reproducibility of a clinical application of a simple technique for repeated circumferential leg measurements

Author keywords

Haemodynamic surgery; Quantification; Saphenectomy

Indexed keywords

ANALYTICAL EQUIPMENT; ANTHROPOMETRIC PARAMETERS; ARTICLE; FEMALE; HUMAN; LEG; LEG EDEMA; MALE; MEASURING TAPE; NORMAL HUMAN; PRIORITY JOURNAL; RELIABILITY; REPRODUCIBILITY; STATISTICAL ANALYSIS; VOLUNTEER;

EID: 78751676506     PISSN: 02683555     EISSN: 14333031     Source Type: Journal    
DOI: 10.1258/phleb.2009.009073     Document Type: Article
Times cited : (19)

References (14)
  • 1
    • 0027874289 scopus 로고
    • Edema after vascular surgery interventions and its therapy
    • Balzer K, Schonebeck I. Edema after vascular surgery interventions and its therapy. Z Lymphol 1993;17:41-7
    • (1993) Z Lymphol , vol.17 , pp. 41-47
    • Balzer, K.1    Schonebeck, I.2
  • 2
    • 0025197433 scopus 로고
    • Doxium 500 in chronic venous insufficiency: A double-blind placebo. Controlled multicentre study
    • Widmer L, Biland L, Barras JP. Doxium 500 in chronic venous insufficiency: a double-blind placebo controlled multicentre study. Int Angiol 1990;9:105-10 (Pubitemid 20338645)
    • (1990) International Angiology , vol.9 , Issue.2 , pp. 105-110
    • Widmer, L.1    Biland, L.2    Barras, J.P.3
  • 3
    • 0033984536 scopus 로고    scopus 로고
    • Edema and leg volume: Methods of assessment
    • Perrin M, Guex JJ. Edema and leg volume: methods of assessment. Angiology 2000;51:9-12 (Pubitemid 30059045)
    • (2000) Angiology , vol.51 , Issue.1 , pp. 9-12
    • Perrin, M.1    Guex, J.J.2
  • 4
    • 0027703511 scopus 로고
    • Direct and indirect methods for the quantification of leg volume: Comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreement
    • Kaulesar Sukul DM, den Hoed PT, Johannes EJ, van Dolder R, Benda E. Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreement. J Biomed Eng 1993;15:477-80
    • (1993) J Biomed Eng , vol.15 , pp. 477-480
    • Kaulesar Sukul, D.M.1    Den Hoed, P.T.2    Johannes, E.J.3    Van Dolder, R.4    Benda, E.5
  • 5
    • 0033914643 scopus 로고    scopus 로고
    • The reliability of leg circumference assessment: A comparison of spring tape measurements and optoelectronic volumetry
    • Labs KH, Tschoepl M, Gamba G, Aschwanden M, Jaeger KA. The reliability of leg circumference assessment: a comparison of spring tape measurements and optoelectronic volumetry. Vasc Med 2000;5:69-74
    • (2000) Vasc Med , vol.5 , pp. 69-74
    • Labs, K.H.1    Tschoepl, M.2    Gamba, G.3    Aschwanden, M.4    Jaeger, K.A.5
  • 6
    • 0031238569 scopus 로고    scopus 로고
    • Soft tissue repair capacity after oxygen-derived free radical-induced damage in one hindlimb of the rat
    • van der Laan L, Oyen WJ, Verhofstad AA, et al. Soft tissue repair capacity after oxygen-derived free radical-induced damage in one hindlimb of the rat. J Surg Res 1997;72:60-9
    • (1997) J Surg Res , vol.72 , pp. 60-69
    • Van Der Laan, L.1    Oyen, W.J.2    Verhofstad, A.A.3
  • 7
    • 34247551629 scopus 로고    scopus 로고
    • Reliability and limits of agreement of circumferential, water displacement, and optoelectronic volumetry in the measurement of upper limb lymphedema
    • Deltombe T, Jamart J, Recloux S, et al. Reliability and limits of agreement of circumferential, water displacement, and optoelectronic volumetry in the measurement of upper limb lymphedema. Lymphology 2007;40:26-34
    • (2007) Lymphology , vol.40 , pp. 26-34
    • Deltombe, T.1    Jamart, J.2    Recloux, S.3
  • 8
    • 33845370310 scopus 로고    scopus 로고
    • Pneumatic pump reduces leg wound complications in cardiac patients
    • Ho CK, Sun MP, Au TW, Chiu CS. Pneumatic pump reduces leg wound complications in cardiac patients. Asian Cardiovasc Thorac Ann 2006;14:452-7
    • (2006) Asian Cardiovasc Thorac Ann , vol.14 , pp. 452-457
    • Ho, C.K.1    Sun, M.P.2    Au, T.W.3    Chiu, C.S.4
  • 9
    • 35448938430 scopus 로고    scopus 로고
    • Intraobserver and interobserver agreements of leg circumference measurements by tape measure based on 3 reference points
    • Tunc R, Caglayan-Tunc A, Kisakol G, Unler GK, Hidayetogly T, Yazici H. Intraobserver and interobserver agreements of leg circumference measurements by tape measure based on 3 reference points. Angiology 2007;58:593-6
    • (2007) Angiology , vol.58 , pp. 593-596
    • Tunc, R.1    Caglayan-Tunc, A.2    Kisakol, G.3    Unler, G.K.4    Hidayetogly, T.5    Yazici, H.6
  • 10
    • 0036169879 scopus 로고    scopus 로고
    • Validity of the Leg-O-Meter, an instrument to measure leg circumference
    • Berard A, Kurz X, Zuccarelli F, Abenhaim L. Validity of the Leg-O-Meter, an instrument to measure leg circumference. Angiology 2002;53:21-8
    • (2002) Angiology , vol.53 , pp. 21-28
    • Berard, A.1    Kurz, X.2    Zuccarelli, F.3    Abenhaim, L.4
  • 11
    • 0033829046 scopus 로고    scopus 로고
    • Test-retest reliability study of a new improved Leg-O-meter, the Leg-O-meter II, in patients suffering from venous insufficiency of the lower limbs
    • Berard A, Zuccarelli F. Test-retest reliability study of a new improved Leg-O-meter, the Leg-O-meter II, in patients suffering from venous insufficiency of the lower limbs. Angiology 2000;51:711-7
    • (2000) Angiology , vol.51 , pp. 711-717
    • Berard, A.1    Zuccarelli, F.2
  • 12
    • 2642661484 scopus 로고    scopus 로고
    • Reliability study of the Leg-O-Meter, an improved tape measure device, in patients with chronic venous insufficiency of the leg
    • VEINES Group (Venous Insufficiency Epidemiologic and Economic Study)
    • Berard A, Kurz X, Zuccarelli F, Ducros JJ, Abanhaim L. Reliability study of the Leg-O-Meter, an improved tape measure device, in patients with chronic venous insufficiency of the leg. VEINES Group (Venous Insufficiency Epidemiologic and Economic Study). Angiology 1998; 49:169-73
    • (1998) Angiology , vol.49 , pp. 169-173
    • Berard, A.1    Kurz, X.2    Zuccarelli, F.3    Ducros, J.J.4    Abanhaim, L.5
  • 13
    • 43149091893 scopus 로고    scopus 로고
    • High day-to-day reliability in lower leg volume measured by water displacement
    • Pasley JD, O'Connor PJ. High day-to-day reliability in lower leg volume measured by water displacement. Eur J Appl Physiol 2008;103:393-8
    • (2008) Eur J Appl Physiol , vol.103 , pp. 393-398
    • Pasley, J.D.1    O'Connor, P.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.