메뉴 건너뛰기




Volumn 287, Issue 1, 2011, Pages 223-230

Rapid determination of 237Np and Pu isotopes in water by inductively-coupled plasma mass spectrometry and alpha spectrometry

Author keywords

DGA Resin; ICP MS; Neptunium; Plutonium; Separation

Indexed keywords

CALCIUM PHOSPHATE; NEPTUNIUM 237; PLUTONIUM;

EID: 78751635814     PISSN: 02365731     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10967-010-0825-9     Document Type: Article
Times cited : (19)

References (17)
  • 1
    • 0036172029 scopus 로고    scopus 로고
    • Application of low energy gamma-spectrometry in rapid actinide analysis for emergency preparedness
    • DOI 10.1023/A:1015094228040
    • DL Stricklin A Tjarnhage U Nygren 2002 Application of low energy gamma-spectrometry in rapid actinide analysis for emergency preparedness J Radioanal Nucl Chem 251 1 69 1:CAS:528:DC%2BD38XitVWhtro%3D 10.1023/A: 1015094228040 (Pubitemid 34145403)
    • (2002) Journal of Radioanalytical and Nuclear Chemistry , vol.251 , Issue.1 , pp. 69-74
    • Stricklin, D.L.1    Tjarnhage, A.2    Nygren, U.3
  • 2
    • 41849104111 scopus 로고    scopus 로고
    • Rapid analysis of emergency urine and water samples
    • DOI 10.1007/s10967-007-7084-4
    • S Maxwell 2008 Rapid analysis of emergency urine and water samples J Radioanal Nucl chem 275 3 497 1:CAS:528:DC%2BD1cXksFWmurk%3D 10.1007/s10967-007-7084-4 (Pubitemid 351501679)
    • (2008) Journal of Radioanalytical and Nuclear Chemistry , vol.275 , Issue.3 , pp. 497-502
    • Maxwell III, S.L.1
  • 3
    • 62349109902 scopus 로고    scopus 로고
    • Rapid separation method for emergency water and urine samples
    • 1:CAS:528:DC%2BD1MXislOitr0%3D 10.1007/s10967-008-7387-0
    • S Maxwell B Culligan 2009 Rapid separation method for emergency water and urine samples J Radioanal Nucl chem 279 3 901 1:CAS:528:DC%2BD1MXislOitr0%3D 10.1007/s10967-008-7387-0
    • (2009) J Radioanal Nucl Chem , vol.279 , Issue.3 , pp. 901
    • Maxwell, S.1    Culligan, B.2
  • 4
    • 70349235360 scopus 로고    scopus 로고
    • Rapid determination of actinides in urine by inductively coupled plasma mass spectrometry and alpha spectrometry: A hybrid approach
    • 1:CAS:528:DC%2BD1MXhtF2hsbzN 10.1016/j.talanta.2009.06.041
    • SL Maxwell VD Jones 2009 Rapid determination of actinides in urine by inductively coupled plasma mass spectrometry and alpha spectrometry: a hybrid approach Talanta 80 1 143 1:CAS:528:DC%2BD1MXhtF2hsbzN 10.1016/j.talanta.2009. 06.041
    • (2009) Talanta , vol.80 , Issue.1 , pp. 143
    • Maxwell, S.L.1    Jones, V.D.2
  • 5
    • 39749131785 scopus 로고    scopus 로고
    • Automated flow injection system using extraction chromatography for the determination of plutonium in urine by inductively coupled plasma mass spectrometry
    • DOI 10.1039/b714135a
    • D Larivière T Cumming S Kiser C Li R Cornett 2008 Automated flow injection system using extraction chromatography for the determination of plutonium in urine by inductively coupled plasma mass spectrometry J Anal Atom Spectrom 23 352 10.1039/b714135a (Pubitemid 351312180)
    • (2008) Journal of Analytical Atomic Spectrometry , vol.23 , Issue.3 , pp. 352-360
    • Lariviere, D.1    Cumming, T.A.2    Kiser, S.3    Li, C.4    Cornett, R.J.5
  • 6
    • 70349309756 scopus 로고    scopus 로고
    • Determination of plutonium isotopes in waters and environmental solids: A review
    • doi: 10.1016/j.aca.2009.03.010(inpress)
    • Hou X, Qiao J, Miro M and Roos R (2009) Determination of plutonium isotopes in waters and environmental solids: a review. Anal Chim Acta. doi: 10.1016/j.aca.2009.03.010 (in press)
    • (2009) Anal Chim Acta.
    • Hou, X.1    Qiao, J.2    Miro, M.3    Roos, R.4
  • 7
    • 77949263030 scopus 로고    scopus 로고
    • Determination of Pu isotopes by alpha spectrometry: A review of analytical methodology
    • 1:CAS:528:DC%2BC3cXhtFegtbk%3D 10.1007/s10967-009-0342-x
    • N Vajda C Kim 2010 Determination of Pu isotopes by alpha spectrometry: a review of analytical methodology J Radioanal Nucl chem 283 1 203 1:CAS:528:DC%2BC3cXhtFegtbk%3D 10.1007/s10967-009-0342-x
    • (2010) J Radioanal Nucl Chem , vol.283 , Issue.1 , pp. 203
    • Vajda, N.1    Kim, C.2
  • 8
    • 34548222643 scopus 로고    scopus 로고
    • Determination of Pu isotope concentrations and isotope ratio by inductively coupled plasma mass spectrometry: A review of analytical methodology
    • DOI 10.1039/b617568f
    • CS Kim N Vajda 2007 Determination of Pu isotope concentrations and isotope ratio by inductively coupled plasma mass spectrometry: a review of analytical methodology J Anal Atom Spectrom 22 827 1:CAS:528: DC%2BD2sXntFOhur0%3D 10.1039/b617568f (Pubitemid 47324832)
    • (2007) Journal of Analytical Atomic Spectrometry , vol.22 , Issue.7 , pp. 827-841
    • Kim, C.-S.1    Kim, C.-K.2    Martin, P.3    Sansone, U.4
  • 9
    • 33847666499 scopus 로고    scopus 로고
    • Rapid sequential determination of americium and plutonium in sediment and soil samples by ICP-SFMS and alpha-spectrometry
    • 1:CAS:528:DC%2BD2sXjtlWjtrY%3D 10.1524/ract.2007.95.2.81
    • Z Varga G Suranyi N Vajda Z Stefanka 2007 Rapid sequential determination of americium and plutonium in sediment and soil samples by ICP-SFMS and alpha-spectrometry Radiochim Acta 95 81 1:CAS:528:DC%2BD2sXjtlWjtrY%3D 10.1524/ract.2007.95.2.81
    • (2007) Radiochim Acta , vol.95 , pp. 81
    • Varga, Z.1    Suranyi, G.2    Vajda, N.3    Stefanka, Z.4
  • 10
    • 19144365306 scopus 로고    scopus 로고
    • Radiochemical separation of actinides from environmental samples for determination with DF-ICP-MS and alpha spectrometry
    • DOI 10.1524/ract.93.5.249.64278
    • M Aryanov U Krahenbuhl H Sahli S Rollin Burger 2005 M. Radiochemical separation of actinides from environmental samples for determination with DF-ICP-MS and alpha spectrometry Radiochim Acta 93 249 10.1524/ract.93.5.249. 64278 (Pubitemid 40717283)
    • (2005) Radiochimica Acta , vol.93 , Issue.5 , pp. 249-257
    • Ayranov, M.1    Krahenbuhl, U.2    Sahli, H.3    Rollin, S.4    Burger, M.5
  • 11
    • 3042589554 scopus 로고    scopus 로고
    • 237Np and Pu isotopes in environmental samples by ICP-SF-MS coupled with automated sequential injection system
    • 1:CAS:528:DC%2BD2cXksF2ltLo%3D 10.1039/b400034j
    • 237Np and Pu isotopes in environmental samples by ICP-SF-MS coupled with automated sequential injection system J Anal Atom Spectrom 19 743 1:CAS:528: DC%2BD2cXksF2ltLo%3D 10.1039/b400034j
    • (2004) J Anal Atom Spectrom , vol.19 , pp. 743
    • Kim, C.S.1    Kim, C.K.2    Lee, K.J.3
  • 12
    • 18144395128 scopus 로고    scopus 로고
    • Novel extraction of chromatographic resins based on tetraalkyldiglycolamides: Characterization and potential applications
    • DOI 10.1081/SEI-200049898
    • P Horwitz D McAlister A Bond AB Barrans Jr 2005 Novel extraction chromatographic resins based on tetraalkyldiglycolamides: characterization and potential applications Solvent Extr Ion Exc 23 3 319 1:CAS:528: DC%2BD2MXkvF2jsbc%3D 10.1081/SEI-200049898 (Pubitemid 40782395)
    • (2005) Solvent Extraction and Ion Exchange , vol.23 , Issue.3 , pp. 319-344
    • Horwitz, E.P.1    McAlister, D.R.2    Bond, A.H.3    Barrans, R.E.4
  • 13
    • 78751624796 scopus 로고    scopus 로고
    • C1590-04, ASTM International, West Conshohocken, PA, USA
    • Jones V, ASTM Vol. 12.01 (2009) C1590-04, ASTM International, West Conshohocken, PA, USA
    • (2009) ASTM , vol.12 , Issue.1
    • Jones, V.1
  • 15
    • 18844423573 scopus 로고    scopus 로고
    • Rapid determination of plutonium in urine using flow injection on-line preconcentration and inductively coupled plasma mass spectrometry
    • DOI 10.1039/b501218j
    • V Epov K Benkhedda RJ Cornett RD Evans 2005 Rapid determination of plutonium in urine using flow injection on-line preconcentration and inductively-coupled plasma mass spectrometry J Anal Atom Spectrom 20 424 1:CAS:528:DC%2BD2MXjsFOktr0%3D 10.1039/b501218j (Pubitemid 40683114)
    • (2005) Journal of Analytical Atomic Spectrometry , vol.20 , Issue.5 , pp. 424-430
    • Epov, V.N.1    Benkhedda, K.2    Cornett, R.J.3    Evans, R.D.4
  • 16
    • 23544462582 scopus 로고
    • Limits for qualitative and quantitative determination
    • 1:CAS:528:DyaF1cXnsVyitQ%3D%3D 10.1021/ac60259a007
    • LA Currie 1968 Limits for qualitative and quantitative determination Anal Chem 40 586 1:CAS:528:DyaF1cXnsVyitQ%3D%3D 10.1021/ac60259a007
    • (1968) Anal Chem , vol.40 , pp. 586
    • Currie, L.A.1
  • 17
    • 77954943861 scopus 로고    scopus 로고
    • Rapid and automated sequential determination of ultra-trace long-lived actinides in air filters by inductively coupled plasma mass spectrometry
    • 10.1039/b9ay00197b 10.1039/b9ay00197b
    • D Larivière K Benkhedda S Kiser S Johnson S Kiser C Li R Cornett 2010 Rapid and automated sequential determination of ultra-trace long-lived actinides in air filters by inductively coupled plasma mass spectrometry Anal Method 2 259 267 10.1039/b9ay00197b 10.1039/b9ay00197b
    • (2010) Anal Method , vol.2 , pp. 259-267
    • Larivière, D.1    Benkhedda, K.2    Kiser, S.3    Johnson, S.4    Kiser, S.5    Li, C.6    Cornett, R.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.