메뉴 건너뛰기




Volumn 53, Issue 1, 2011, Pages 23-30

A study of the first-generation pipeline embolization device morphology using intraoperative angiographic computed tomography (ACT)

Author keywords

Angiographic computed tomography; Pipeline embolization device; Stent profile; Wall apposition

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; HEPARIN; METAL; PLATINUM; STAINLESS STEEL;

EID: 78751631557     PISSN: 00283940     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00234-010-0709-2     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 67650102825 scopus 로고    scopus 로고
    • Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: The Buenos Aires experience
    • 10.1227/01.NEU.0000339109.98070.65 19349825
    • P Lylyk C Miranda R Ceratto, et al. 2009 Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience Neurosurgery 64 632 642 10.1227/01.NEU.0000339109.98070. 65 19349825
    • (2009) Neurosurgery , vol.64 , pp. 632-642
    • Lylyk, P.1    Miranda, C.2    Ceratto, R.3
  • 2
    • 61449257381 scopus 로고    scopus 로고
    • Curative reconstruction of a giant midbasilar trunk aneurysm with the pipeline embolization device
    • 10.1227/01.NEU.0000337576.98984.E4 19057425
    • D Fiorella ME Kelly FC Albuquerque PK Nelson 2009 Curative reconstruction of a giant midbasilar trunk aneurysm with the pipeline embolization device Neurosurgery 64 212 217 10.1227/01.NEU.0000337576.98984.E4 19057425
    • (2009) Neurosurgery , vol.64 , pp. 212-217
    • Fiorella, D.1    Kelly, M.E.2    Albuquerque, F.C.3    Nelson, P.K.4
  • 3
    • 49049090042 scopus 로고    scopus 로고
    • Definitive reconstruction of circumferential, fusiform intracranial aneurysms with the pipeline embolization device
    • 10.1227/01.neu.0000325873.44881.6e 18580809
    • D Fiorella HH Woo FC Albuquerque PK Nelson 2008 Definitive reconstruction of circumferential, fusiform intracranial aneurysms with the pipeline embolization device Neurosurgery 62 1115 1120 10.1227/01.neu.0000325873.44881.6e 18580809
    • (2008) Neurosurgery , vol.62 , pp. 1115-1120
    • Fiorella, D.1    Woo, H.H.2    Albuquerque, F.C.3    Nelson, P.K.4
  • 4
    • 34548250908 scopus 로고    scopus 로고
    • A new endoluminal, flow-disrupting device for treatment of saccular aneurysms
    • DOI 10.1161/STROKEAHA.106.479576, PII 0000767020070800000037
    • DF Kallmes YH Ding D Dai R Kadirvel DA Lewis HJ Cloft 2007 A new endoluminal, flow-disrupting device for treatment of saccular aneurysms Stroke 38 2346 2352 10.1161/STROKEAHA.106.479576 17615366 (Pubitemid 47457579)
    • (2007) Stroke , vol.38 , Issue.8 , pp. 2346-2352
    • Kallmes, D.F.1    Ding, Y.H.2    Dai, D.3    Kadirvel, R.4    Lewis, D.A.5    Cloft, H.J.6
  • 5
    • 33646183667 scopus 로고    scopus 로고
    • Increased cell opening and prolapse of struts of a neuroform stent in curved vasculature: Value of angiographic computed tomography: Technical case report
    • G Benndorf B Claus CM Strother L Chang RP Klucznik 2006 Increased cell opening and prolapse of struts of a neuroform stent in curved vasculature: value of angiographic computed tomography: technical case report Neurosurgery 58 ONS E380
    • (2006) Neurosurgery , vol.58 , pp. 380
    • Benndorf, G.1    Claus, B.2    Strother, C.M.3    Chang, L.4    Klucznik, R.P.5
  • 6
    • 34248639072 scopus 로고    scopus 로고
    • Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: An in vitro study
    • 1:STN:280:DC%2BD2s3os1Smsw%3D%3D 17494650
    • N Ebrahimi B Claus CY Lee A Biondi G Benndorf 2007 Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study AJNR Am J Neuroradiol 28 823 829 1:STN:280:DC%2BD2s3os1Smsw%3D%3D 17494650
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 823-829
    • Ebrahimi, N.1    Claus, B.2    Lee, C.Y.3    Biondi, A.4    Benndorf, G.5
  • 8
    • 24344476327 scopus 로고    scopus 로고
    • Angiographic CT in cerebrovascular stenting
    • 16091535
    • G Benndorf CM Strother B Claus, et al. 2005 Angiographic CT in cerebrovascular stenting AJNR Am J Neuroradiol 26 1813 1818 16091535
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 1813-1818
    • Benndorf, G.1    Strother, C.M.2    Claus, B.3
  • 9
    • 59249104268 scopus 로고    scopus 로고
    • Evaluation of angiographic computed tomography in the follow-up after endovascular treatment of cerebral aneurysms-a comparative study with DSA and TOF-MRA
    • 10.1007/s00330-008-1171-y 18810455
    • JH Buhk K Kallenberg A Mohr P Dechent M Knauth 2009 Evaluation of angiographic computed tomography in the follow-up after endovascular treatment of cerebral aneurysms-a comparative study with DSA and TOF-MRA Eur Radiol 19 430 436 10.1007/s00330-008-1171-y 18810455
    • (2009) Eur Radiol , vol.19 , pp. 430-436
    • Buhk, J.H.1    Kallenberg, K.2    Mohr, A.3    Dechent, P.4    Knauth, M.5
  • 10
    • 41149103858 scopus 로고    scopus 로고
    • Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting
    • 10.1007/s00234-007-0342-x 18246336
    • JH Buhk P Lingor M Knauth 2008 Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting Neuroradiology 50 349 354 10.1007/s00234-007-0342-x 18246336
    • (2008) Neuroradiology , vol.50 , pp. 349-354
    • Buhk, J.H.1    Lingor, P.2    Knauth, M.3
  • 11
    • 51649088458 scopus 로고    scopus 로고
    • Flat panel detector angiographic CT in the management of aneurysmal rupture during coil embolization
    • 1:STN:280:DC%2BD1crpt1Wksg%3D%3D 10.3174/ajnr.A1119 18499792
    • T Engelhorn T Struffert G Richter, et al. 2008 Flat panel detector angiographic CT in the management of aneurysmal rupture during coil embolization AJNR Am J Neuroradiol 29 1581 1584 1:STN:280:DC%2BD1crpt1Wksg%3D%3D 10.3174/ajnr.A1119 18499792
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 1581-1584
    • Engelhorn, T.1    Struffert, T.2    Richter, G.3
  • 13
    • 34248227700 scopus 로고    scopus 로고
    • Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation
    • DOI 10.1161/CIRCULATIONAHA.106.658237, PII 0000301720070508000012
    • S Cook P Wenaweser M Togni, et al. 2007 Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation Circulation 115 2426 2434 1:CAS:528:DC%2BD2sXkslOht7c%3D 10.1161/CIRCULATIONAHA.106.658237 17485593 (Pubitemid 46717965)
    • (2007) Circulation , vol.115 , Issue.18 , pp. 2426-2434
    • Cook, S.1    Wenaweser, P.2    Togni, M.3    Billinger, M.4    Morger, C.5    Seiler, C.6    Vogel, R.7    Hess, O.8    Meier, B.9    Windecker, S.10
  • 14
    • 67449152713 scopus 로고    scopus 로고
    • A second-generation, endoluminal, flow-disrupting device for treatment of saccular aneurysms
    • 1:STN:280:DC%2BD1MvhtFertA%3D%3D 10.3174/ajnr.A1530 19369609
    • DF Kallmes YH Ding D Dai R Kadirvel DA Lewis HJ Cloft 2009 A second-generation, endoluminal, flow-disrupting device for treatment of saccular aneurysms AJNR Am J Neuroradiol 30 1153 1158 1:STN:280:DC%2BD1MvhtFertA%3D%3D 10.3174/ajnr.A1530 19369609
    • (2009) AJNR Am J Neuroradiol , vol.30 , pp. 1153-1158
    • Kallmes, D.F.1    Ding, Y.H.2    Dai, D.3    Kadirvel, R.4    Lewis, D.A.5    Cloft, H.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.