메뉴 건너뛰기




Volumn 26, Issue 2, 2011, Pages 289-295

The Addition of a Hydroxyapatite Coating Changes the Immediate Postoperative Stability of a Plasma-Sprayed Femoral Stem

Author keywords

Femoral stem; HA; Hip; Micromotion; Stability

Indexed keywords

HYDROXYAPATITE; TITANIUM;

EID: 78751582139     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2010.02.004     Document Type: Article
Times cited : (21)

References (10)
  • 1
    • 0242330709 scopus 로고    scopus 로고
    • Osseointegration in hip prostheses: experimental study in sheep
    • Doria C., De Santis V., Falcone G., et al. Osseointegration in hip prostheses: experimental study in sheep. Int Orthop 2003, 27:272.
    • (2003) Int Orthop , vol.27 , pp. 272
    • Doria, C.1    De Santis, V.2    Falcone, G.3
  • 3
    • 0033851948 scopus 로고    scopus 로고
    • The Norwegian arthroplasty register: 11 years and 73,000 arthroplasties
    • Havelin L.I., Engesæter L.B., Espehaug B., et al. The Norwegian arthroplasty register: 11 years and 73,000 arthroplasties. Acta Orthop Scand 2000, 71:337.
    • (2000) Acta Orthop Scand , vol.71 , pp. 337
    • Havelin, L.I.1    Engesæter, L.B.2    Espehaug, B.3
  • 4
    • 1842578572 scopus 로고    scopus 로고
    • Prospective matched-pair analysis of hydroxyapatite-coated and uncoated femoral stems in total hip arthroplasty: a concise follow-up of a previous report
    • Parvizi J., Sharkey P.F., Hozack W.J., et al. Prospective matched-pair analysis of hydroxyapatite-coated and uncoated femoral stems in total hip arthroplasty: a concise follow-up of a previous report. J Bone Joint Surg - Series A 2004, 86:783.
    • (2004) J Bone Joint Surg - Series A , vol.86 , pp. 783
    • Parvizi, J.1    Sharkey, P.F.2    Hozack, W.J.3
  • 5
    • 35648983493 scopus 로고    scopus 로고
    • Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry
    • Paulsen A., Pedersen A.B., Johnsen S.P., et al. Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry. Acta Orthop 2007, 78:622.
    • (2007) Acta Orthop , vol.78 , pp. 622
    • Paulsen, A.1    Pedersen, A.B.2    Johnsen, S.P.3
  • 6
    • 0037397195 scopus 로고    scopus 로고
    • Early cement damage around a femoral stem is concentrated at the cement/bone interface
    • Race A., Miller M.A., Ayers D.C., et al. Early cement damage around a femoral stem is concentrated at the cement/bone interface. J Biomech 2003, 36:489.
    • (2003) J Biomech , vol.36 , pp. 489
    • Race, A.1    Miller, M.A.2    Ayers, D.C.3
  • 7
    • 27644501807 scopus 로고    scopus 로고
    • Cement/implant interface gaps explain the poor results of CMW3 for femoral stem fixation: a cadaver study of migration, fatigue and mantle morphology
    • Race A., Miller M.A., Clarke M.T., et al. Cement/implant interface gaps explain the poor results of CMW3 for femoral stem fixation: a cadaver study of migration, fatigue and mantle morphology. Acta Orthop 2005, 5:679.
    • (2005) Acta Orthop , vol.5 , pp. 679
    • Race, A.1    Miller, M.A.2    Clarke, M.T.3
  • 8
    • 0036121672 scopus 로고    scopus 로고
    • Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years
    • Reikeras O., Gunderson R.B. Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years. Acta Orthop Scand 2002, 73:104.
    • (2002) Acta Orthop Scand , vol.73 , pp. 104
    • Reikeras, O.1    Gunderson, R.B.2
  • 9
    • 3042536268 scopus 로고    scopus 로고
    • HA particles can be released from well-fixed HA-coated stems: histopathology of biopsies from 20 hips 2-8 years after implantation
    • Rokkum M., Reigstad A., Johansson C.B. HA particles can be released from well-fixed HA-coated stems: histopathology of biopsies from 20 hips 2-8 years after implantation. Acta Orthop Scand 2002, 73:298.
    • (2002) Acta Orthop Scand , vol.73 , pp. 298
    • Rokkum, M.1    Reigstad, A.2    Johansson, C.B.3
  • 10
    • 0028121039 scopus 로고
    • Complications with hydroxyapatite particulate separation in total hip arthroplasty
    • Bloebaum R.D., Beeks D., Dorr L.D., et al. Complications with hydroxyapatite particulate separation in total hip arthroplasty. Clin Orthop 1994, 19.
    • (1994) Clin Orthop , pp. 19
    • Bloebaum, R.D.1    Beeks, D.2    Dorr, L.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.