메뉴 건너뛰기




Volumn 89, Issue 1, 2011, Pages 48-54

Rearrangement of membrane elements in the pressure vessels for optimum utilization of reverse osmosis process

Author keywords

Membrane; Module; Pressure vessel; Rearrangement; Reverses osmosis

Indexed keywords

BIOLOGICAL FOULING; COLLOIDAL FOULING; CONCENTRATION POLARIZATION; DIFFERENTIAL PRESSURES; EXPENSIVE PARTS; FIELD STUDIES; LIFE-TIMES; MEMBRANE ELEMENTS; MEMBRANE PERFORMANCE; MODULE; PETROCHEMICAL COMPANY; REARRANGEMENT; REVERSES OSMOSIS; USEFUL LIFE;

EID: 78651502606     PISSN: 02638762     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cherd.2010.04.021     Document Type: Article
Times cited : (5)

References (11)
  • 2
    • 8644268756 scopus 로고    scopus 로고
    • Seawater RO plant operation and maintenance experience: Addur desalination plant operation assessment
    • Burashida K., Hussain A.R. Seawater RO plant operation and maintenance experience: Addur desalination plant operation assessment. Desalination 2004, 165:11-22.
    • (2004) Desalination , vol.165 , pp. 11-22
    • Burashida, K.1    Hussain, A.R.2
  • 3
    • 78651487689 scopus 로고
    • Microorganism characterization for solving biological problems
    • March-April
    • Farkas S.J., Smith A. Microorganism characterization for solving biological problems. Industrial Water Treatment 1992, (March-April):34-38.
    • (1992) Industrial Water Treatment , pp. 34-38
    • Farkas, S.J.1    Smith, A.2
  • 4
    • 0034351552 scopus 로고    scopus 로고
    • UF/RO treatment plant Heemskerk: from challenge to full scale application
    • Kamp Peer C., et al. UF/RO treatment plant Heemskerk: from challenge to full scale application. Desalination 2000, 131:27-35.
    • (2000) Desalination , vol.131 , pp. 27-35
    • Kamp Peer, C.1
  • 5
    • 12244312470 scopus 로고    scopus 로고
    • Pre-treatment optimisation studies for secondary effluent reclamation with reverse osmosis
    • Lopez-Ramirez J.A., et al. Pre-treatment optimisation studies for secondary effluent reclamation with reverse osmosis. Water Research 2003, 37:1177-1184.
    • (2003) Water Research , vol.37 , pp. 1177-1184
    • Lopez-Ramirez, J.A.1
  • 6
    • 26844517954 scopus 로고    scopus 로고
    • Dynamics of organic carbon and of bacterial populations in a conventional pretreatment train of a reverse osmosis unit experiencing severe biofouling
    • Schneider R.P., et al. Dynamics of organic carbon and of bacterial populations in a conventional pretreatment train of a reverse osmosis unit experiencing severe biofouling. Journal of Membrane Science 2005, 266:18-29.
    • (2005) Journal of Membrane Science , vol.266 , pp. 18-29
    • Schneider, R.P.1
  • 7
    • 33846623765 scopus 로고    scopus 로고
    • The membrane fouling simulator as a new tool for biofouling control of spiral-wound membranes
    • Vrouwenvelder J.S., Bakker S.M., Wessels L.P., Van Paassen J.A.M. The membrane fouling simulator as a new tool for biofouling control of spiral-wound membranes. Desalination 2007, 204:170-174.
    • (2007) Desalination , vol.204 , pp. 170-174
    • Vrouwenvelder, J.S.1    Bakker, S.M.2    Wessels, L.P.3    Van Paassen, J.A.M.4
  • 9
    • 66649130021 scopus 로고    scopus 로고
    • Pressure drop increase by biofilm accumulation in spiral wound RO and NF membrane systems: role of substrate concentration, flow velocity, substrate load and flow direction
    • Vrouwenvelder J.S., Hinrichs C., Van der Meer W.G.J., Van Loosdrecht M.C.M., Kruithof J.C. Pressure drop increase by biofilm accumulation in spiral wound RO and NF membrane systems: role of substrate concentration, flow velocity, substrate load and flow direction. Biofouling 2009, 25:543-555.
    • (2009) Biofouling , vol.25 , pp. 543-555
    • Vrouwenvelder, J.S.1    Hinrichs, C.2    Van der Meer, W.G.J.3    Van Loosdrecht, M.C.M.4    Kruithof, J.C.5
  • 10
    • 0000936029 scopus 로고
    • Control of organic fouling at two sea water reverse osmosis plant
    • Winters H. Control of organic fouling at two sea water reverse osmosis plant. Desalination 1987, 79:319-325.
    • (1987) Desalination , vol.79 , pp. 319-325
    • Winters, H.1
  • 11
    • 34249806392 scopus 로고
    • Biofouling of reverse osmosis systems. Three cast studies
    • Woods D., Pierce C., Zeiher E.H. Biofouling of reverse osmosis systems. Three cast studies. Ultra Pure Water 1991, 50-64.
    • (1991) Ultra Pure Water , pp. 50-64
    • Woods, D.1    Pierce, C.2    Zeiher, E.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.