메뉴 건너뛰기




Volumn 35, Issue 2, 2011, Pages 319-328

Finding a trade-off between observability and economics in the fault detection of chemical processes

Author keywords

Average run length; Economic significance; Fault detection; Observability; PCA

Indexed keywords

AVERAGE RUN LENGTHS; CLOSED-LOOP OPERATION; DETECTION OF CHEMICALS; DIFFERENT FREQUENCY; ECONOMIC LOSS; FREQUENCY DOMAINS; OPTIMIZATION APPROACH; PCA; PRODUCT VARIABILITY; STATISTICAL MONITORING; TIME DOMAIN;

EID: 78651417659     PISSN: 00981354     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compchemeng.2010.04.006     Document Type: Article
Times cited : (11)

References (22)
  • 1
    • 0001393743 scopus 로고
    • An approach to the probability distribution of CUSUM run length
    • Brook D., Evans D.A. An approach to the probability distribution of CUSUM run length. Biometrika 1972, 59:539.
    • (1972) Biometrika , vol.59 , pp. 539
    • Brook, D.1    Evans, D.A.2
  • 4
    • 0024122587 scopus 로고
    • Survey of model based failure detection and isolation in complex plants
    • Gertler J. Survey of model based failure detection and isolation in complex plants. IEEE Control Systems Magazine 1988, 3.
    • (1988) IEEE Control Systems Magazine , pp. 3
    • Gertler, J.1
  • 6
    • 0021468997 scopus 로고
    • Process fault detection based on modeling and estimation methods-A survey
    • Isermann R. Process fault detection based on modeling and estimation methods-A survey. Automatica 1984, 20:387.
    • (1984) Automatica , vol.20 , pp. 387
    • Isermann, R.1
  • 9
    • 0026243221 scopus 로고
    • An integrated approach to controls and diagnosis using the four parameter controller
    • Jacobson C.A., Nett C.N. An integrated approach to controls and diagnosis using the four parameter controller. IEEE Control Systems 1991, 11:22.
    • (1991) IEEE Control Systems , vol.11 , pp. 22
    • Jacobson, C.A.1    Nett, C.N.2
  • 10
    • 0020165826 scopus 로고
    • Fast initial response for CUSUM quality control schemes: Give your CUSUM a head start
    • Lucas J.M., Crosier R.B. Fast initial response for CUSUM quality control schemes: Give your CUSUM a head start. Technometrics 1982, 24:199.
    • (1982) Technometrics , vol.24 , pp. 199
    • Lucas, J.M.1    Crosier, R.B.2
  • 11
  • 13
    • 0033083172 scopus 로고    scopus 로고
    • Locating sensors in complex chemical plants based on fault diagnostic observability criteria
    • Raghuraj R., Bhushan M., Rengaswamy R. Locating sensors in complex chemical plants based on fault diagnostic observability criteria. AIChE Journal 1999, 45:310.
    • (1999) AIChE Journal , vol.45 , pp. 310
    • Raghuraj, R.1    Bhushan, M.2    Rengaswamy, R.3
  • 16
    • 0036805513 scopus 로고    scopus 로고
    • Process analysis and abnormal situation detection: From theory to practice
    • Kourti T. Process analysis and abnormal situation detection: From theory to practice. IEEE Control Systems Magazine 2002, 10.
    • (2002) IEEE Control Systems Magazine , pp. 10
    • Kourti, T.1
  • 18
    • 0037443771 scopus 로고    scopus 로고
    • A review of process fault detection and diagnosis. Part II. Qualitative models and search strategies
    • Venkatasubramanian V., Rengaswamy R., Kavuri N. A review of process fault detection and diagnosis. Part II. Qualitative models and search strategies. Computers & Chemical Engineering 2003, 27:313.
    • (2003) Computers & Chemical Engineering , vol.27 , pp. 313
    • Venkatasubramanian, V.1    Rengaswamy, R.2    Kavuri, N.3
  • 21
    • 0017022844 scopus 로고
    • A survey of design methods for faultier detections in dynamic systems
    • Willsky A.S. A survey of design methods for faultier detections in dynamic systems. Automatica 1976, 12:601.
    • (1976) Automatica , vol.12 , pp. 601
    • Willsky, A.S.1
  • 22
    • 0022111936 scopus 로고
    • Multivariate CUSUM quality control procedures
    • Woodall W., Ncube M. Multivariate CUSUM quality control procedures. Technometrics 1985, 27:285.
    • (1985) Technometrics , vol.27 , pp. 285
    • Woodall, W.1    Ncube, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.