메뉴 건너뛰기




Volumn 4, Issue 1, 2011, Pages 17-30

Building energy information systems: User case studies

Author keywords

Anomaly detection; Baselining; Benchmarking; Diagnostics; Energy analysis; Energy efficiency; Energy information system; Enterprise energy management; Performance monitoring; Web based energy management and control system

Indexed keywords

ANOMALY DETECTION; BENCHMARKING; DATA ACQUISITION; ENERGY MANAGEMENT; ENERGY MANAGEMENT SYSTEMS; INFORMATION MANAGEMENT; INFORMATION SYSTEMS; INFORMATION USE; PLASMA DIAGNOSTICS;

EID: 78651296664     PISSN: 1570646X     EISSN: 15706478     Source Type: Journal    
DOI: 10.1007/s12053-010-9084-4     Document Type: Article
Times cited : (68)

References (22)
  • 1
    • 84881163038 scopus 로고    scopus 로고
    • Setting enhanced performance targets for a new university campus: Benchmarks vs. energy standards as a reference?
    • Brown, K. (2002). Setting enhanced performance targets for a new university campus: Benchmarks vs. energy standards as a reference? American Council for an Energy-Efficient Economy Summer Study Proceedings, 4, 29-40.
    • (2002) American Council for an Energy-Efficient Economy Summer Study Proceedings , vol.4 , pp. 29-40
    • Brown, K.1
  • 3
    • 78651297713 scopus 로고    scopus 로고
    • Money & Energy Saving Resources from the California Energy Commission
    • California Energy Commission, California Energy Commission publication #400-02-005F, Accessed February 2010
    • California Energy Commission. (2002). Money & Energy Saving Resources from the California Energy Commission. Enhanced Automation Technical Options Guidebook. California Energy Commission publication #400-02-005F. http://www. energy. ca. gov/enhancedautomation/documents/400-02-005F_TECH_OPTIONS. PDF. Accessed February 2010.
    • (2002) Enhanced Automation Technical Options Guidebook
  • 5
    • 84902602077 scopus 로고    scopus 로고
    • B. Capehart, L. Capehart, P. Allen, and D. Green (Eds.), Lilburn, GA: Fairmont Press, Inc
    • Capehart, B., Capehart, L., Allen, P., & Green, D. (Eds.). (2007). Web based enterprise energy and building automation systems. Lilburn, GA: Fairmont Press, Inc.
    • (2007) Web Based Enterprise Energy and Building Automation Systems
  • 6
    • 77954406340 scopus 로고    scopus 로고
    • The effectiveness of feedback on energy consumption: A review for DEFRA of the literature on metering, billing, and direct displays
    • University of Oxford, Accessed November 2009
    • Darby, S. (2006). The effectiveness of feedback on energy consumption: A review for DEFRA of the literature on metering, billing, and direct displays. Environmental Change Institute, University of Oxford. http://www. eci. ox. ac. uk/research/energy/downloads/smart-metering-report. pdf. Accessed November 2009.
    • (2006) Environmental Change Institute
    • Darby, S.1
  • 8
    • 78651300837 scopus 로고    scopus 로고
    • Lawrence Berkeley National Laboratory. Paper LBNL-47698, Accessed November 2009
    • Friedman, H., & Piette, M. A. (2001). Comparison of emerging diagnostic tools for HVAC systems. Lawrence Berkeley National Laboratory. Paper LBNL-47698. http://repositories. cdlib. org/lbnl/LBNL-47698/. Accessed November 2009.
    • (2001) Comparison of emerging diagnostic tools for HVAC systems
    • Friedman, H.1    Piette, M.A.2
  • 9
    • 78651316827 scopus 로고    scopus 로고
    • Preliminary findings from an analysis of building Energy Information System technologies
    • Lawrence Berkley National Laboratory. Paper LBNL-2224E., Accessed February 2010
    • Granderson, J., Piette, M. A., Ghatikar, G., & Price, P. (2009). Preliminary findings from an analysis of building Energy Information System technologies. Proceedings of the National Conference on Building Commissioning. Lawrence Berkley National Laboratory. Paper LBNL-2224E. http://eis. lbl. gov/pubs/lbnl-2224e. pdf. Accessed February 2010.
    • (2009) Proceedings of the National Conference on Building Commissioning
    • Granderson, J.1    Piette, M.A.2    Ghatikar, G.3    Price, P.4
  • 11
    • 84884643851 scopus 로고    scopus 로고
    • Is what they want what they get? Examining field evidence for links between design intent and as-built energy performance of commercial buildings
    • Johnson, J. (2002). Is what they want what they get? Examining field evidence for links between design intent and as-built energy performance of commercial buildings. American Council for an Energy-Efficient Economy Summer Study Proceedings, 4, 161-170.
    • (2002) American Council for an Energy-Efficient Economy Summer Study Proceedings , vol.4 , pp. 161-170
    • Johnson, J.1
  • 13
    • 78651271461 scopus 로고    scopus 로고
    • The cost-effectiveness of commissioning new and existing commercial buildings: Lessons from 224 buildings
    • Lawrence Berkeley National Laboratory Report No. 56637, Accessed January 2010
    • Mills, E., Bourassa, N., Piette, M. A., Friedman, H., Haasl, T., Powell, T., et al. (2005). The cost-effectiveness of commissioning new and existing commercial buildings: Lessons from 224 buildings. Proceedings of the National Conference on Building Commissioning. Lawrence Berkeley National Laboratory Report No. 56637. http://eetd. lbl. gov/emills/PUBS/PDF/NCBC_Mills_6Apr05. pdf. Accessed January 2010.
    • (2005) Proceedings of the National Conference on Building Commissioning
    • Mills, E.1    Bourassa, N.2    Piette, M.A.3    Friedman, H.4    Haasl, T.5    Powell, T.6
  • 15
    • 20344386913 scopus 로고    scopus 로고
    • Case studies of energy information systems and related technology: operational practices, costs, and benefits
    • Accessed September 2009
    • Motegi, N., Piette, M. A., Kinney, S., & Dewey, J. (2003). Case studies of energy information systems and related technology: operational practices, costs, and benefits. Proceedings of the International Conference for Enhanced Building. http://txspace. tamu. edu/handle/1969. 1/5195. Accessed September 2009.
    • (2003) Proceedings of the International Conference for Enhanced Building
    • Motegi, N.1    Piette, M.A.2    Kinney, S.3    Dewey, J.4
  • 16
    • 64549115173 scopus 로고    scopus 로고
    • New Buildings Institute, Prepared for the US Green Building Council, Accessed January 2010
    • New Buildings Institute. (2008). Energy performance of LEED for new construction buildings. Prepared for the US Green Building Council. http://www. newbuildings. org/sites/default/files/Energy_Performance_of_LEED-NC_Buildings-Final_3-4-08b. pdf. Accessed January 2010.
    • (2008) Energy performance of LEED for new construction buildings
  • 17
    • 85031972225 scopus 로고    scopus 로고
    • New Buildings Institute, Prepared for the US Environmental Protection Agency, Grant 83378201, Accessed January 2010
    • New Buildings Institute. (2009). Advanced metering and energy information systems. Prepared for the US Environmental Protection Agency, Grant 83378201. http://www. newbuildings. org/sites/default/files/metering-EPA%2083378201. pdf. Accessed January 2010.
    • (2009) Advanced metering and energy information systems
  • 18
    • 78651315525 scopus 로고    scopus 로고
    • New Buildings Institute, with the California Institute for Energy and Environment, UC Merced, Accessed January 2010
    • New Buildings Institute, with the California Institute for Energy and Environment. (2009). Measured Performance Case Study: Classroom and Office Building, UC Merced. http://www. newbuildings. org/sites/default/files/Case_Study_UCM-COB. pdf. Accessed January 2010.
    • (2009) Measured Performance Case Study: Classroom and Office Building
  • 21
    • 0035480252 scopus 로고    scopus 로고
    • Analysis of an information monitoring and diagnostic system to improve building operations
    • Piette, M. A., Kinney, S., & Haves, P. (2001b). Analysis of an information monitoring and diagnostic system to improve building operations. Energy and Buildings, 33(8), 783-791.
    • (2001) Energy and Buildings , vol.33 , Issue.8 , pp. 783-791
    • Piette, M.A.1    Kinney, S.2    Haves, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.