메뉴 건너뛰기




Volumn 37, Issue 1, 2011, Pages 12-17

An investigation into the influence of various gases and concentrations of sclerosants on foam stability

Author keywords

[No Author keywords available]

Indexed keywords

CARBON DIOXIDE; OXYGEN; SCLEROSING AGENT; TETRADECYL SULFATE SODIUM;

EID: 78651295416     PISSN: 10760512     EISSN: 15244725     Source Type: Journal    
DOI: 10.1111/j.1524-4725.2010.01832.x     Document Type: Article
Times cited : (42)

References (13)
  • 1
    • 34547782295 scopus 로고    scopus 로고
    • Systematic review of foam sclerotherapy for varicose veins
    • Jia X, Mowat G, Burr JM, et al,. Systematic review of foam sclerotherapy for varicose veins. Br J Surg 2007; 94: 925-36.
    • (2007) Br J Surg , vol.94 , pp. 925-936
    • Jia, X.1    Mowat, G.2    Burr, J.M.3
  • 2
    • 40349113272 scopus 로고    scopus 로고
    • 2nd European Consensus Meeting on Foam Sclerotherapy 2006, Tegernsee, Germany
    • Breu FX, Guggenbichler S, Wollmann JC., 2nd European Consensus Meeting on Foam Sclerotherapy 2006, Tegernsee, Germany. VASA 2008; 37 (Suppl 71): 1-29.
    • (2008) VASA , vol.37 , Issue.SUPPL. 71 , pp. 1-29
    • Breu, F.X.1    Guggenbichler, S.2    Wollmann, J.C.3
  • 3
    • 33845501837 scopus 로고    scopus 로고
    • Â polidocanol microfoam compared with surgery or sclerotherapy in the management of moderate to severe varicose veins: European randomized controlled trial
    • Â polidocanol microfoam compared with surgery or sclerotherapy in the management of moderate to severe varicose veins: European randomized controlled trial. Phlebology 2006; 21: 180-90.
    • (2006) Phlebology , vol.21 , pp. 180-190
    • Wright, D.1    Gobin, J.P.2    Bradbury, A.W.3
  • 4
    • 11844299570 scopus 로고    scopus 로고
    • Stability of foam in sclerotherapy: Differences between sodium tetradecyl sulfate and polidocanol and the type of connector used in the double-syringe system technique
    • Rao J, Goldman MP., Stability of foam in sclerotherapy: differences between sodium tetradecyl sulfate and polidocanol and the type of connector used in the double-syringe system technique. Dermatol Surg 2005; 31: 19-22.
    • (2005) Dermatol Surg. , vol.31 , pp. 19-22
    • Rao, J.1    Goldman, M.P.2
  • 5
    • 0036154853 scopus 로고    scopus 로고
    • Sclerosing foam in the treatment of varicose veins and telangiectases: History and analysis of safety and complications
    • Frullini A, Cavezzi A., Sclerosing foam in the treatment of varicose veins and telangiectases: history and analysis of safety and complications. Dermatol Surg 2002; 28: 11-5.
    • (2002) Dermatol Surg. , vol.28 , pp. 11-15
    • Frullini, A.1    Cavezzi, A.2
  • 6
    • 78651286786 scopus 로고    scopus 로고
    • Oxygen transfer in cell culture bioreactors
    • Hu WS., Oxygen transfer in cell culture bioreactors. Cell Biopress Technol 2004; 1-14.
    • (2004) Cell Biopress Technol , pp. 1-14
    • Hu, W.S.1
  • 7
    • 55149111854 scopus 로고    scopus 로고
    • Assessment of techniques to reduce sclerosant foam migration during ultrasound-guided sclerotherapy of the great saphenous vein
    • Hill D, Hamilton R, Fung T., Assessment of techniques to reduce sclerosant foam migration during ultrasound-guided sclerotherapy of the great saphenous vein. J Vasc Surg 2008; 48: 934-9.
    • (2008) J Vasc Surg , vol.48 , pp. 934-939
    • Hill, D.1    Hamilton, R.2    Fung, T.3
  • 8
    • 34547112025 scopus 로고    scopus 로고
    • Foam sclerotherapyâa possible option in therapy of varicose veins
    • Kendler M, Wetzig T, Simon JC., Foam sclerotherapyâa possible option in therapy of varicose veins. J Dtsch Dermatol Ges 2007; 5: 648-54.
    • (2007) J Dtsch Dermatol Ges , vol.5 , pp. 648-654
    • Kendler, M.1    Wetzig, T.2    Simon, J.C.3
  • 9
    • 2042517547 scopus 로고    scopus 로고
    • The history of sclerosing foams
    • Wollmann JC., The history of sclerosing foams. Dermatol Surg 2004; 30: 694-703.
    • (2004) Dermatol Surg , vol.30 , pp. 694-703
    • Wollmann, J.C.1
  • 10
    • 72149132800 scopus 로고    scopus 로고
    • Foam sclerotherapy techniques: Different gases methods and methods of preparation, catheter versus direct injection
    • Cavezzi A, Tessari L., Foam sclerotherapy techniques: different gases methods and methods of preparation, catheter versus direct injection. Phlebology 2009; 24: 247-51.
    • (2009) Phlebology , vol.24 , pp. 247-251
    • Cavezzi, A.1    Tessari, L.2
  • 11
    • 78651319394 scopus 로고    scopus 로고
    • Altitude and oxygenation
    • (accessed November 26)
    • Nehrenz GM., Altitude and oxygenation. Internet J Aeromed Transport 2000; 1 Available at (accessed November 26, 2010).
    • (2000) Internet J Aeromed Transport , vol.1
    • Nehrenz, G.M.1
  • 12
    • 46749111916 scopus 로고    scopus 로고
    • Does the relative silicone content of different syringes affect the stability of foam in sclerotherapy?
    • Lai SW, Goldman MP., Does the relative silicone content of different syringes affect the stability of foam in sclerotherapy? J Drugs Dermatol 2008; 7: 399-400.
    • (2008) J Drugs Dermatol , vol.7 , pp. 399-400
    • Lai, S.W.1    Goldman, M.P.2
  • 13
    • 41149091094 scopus 로고    scopus 로고
    • Comparisons of side effects using air and carbon dioxide foam for endovenous chemical ablation
    • Morrison N, Neuhardt DL, Rogers CR, et al,. Comparisons of side effects using air and carbon dioxide foam for endovenous chemical ablation. J Vasc Surg 2008; 47: 830-6.
    • (2008) J Vasc Surg , vol.47 , pp. 830-836
    • Morrison, N.1    Neuhardt, D.L.2    Rogers, C.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.