메뉴 건너뛰기




Volumn 25, Issue 1, 2011, Pages 162-165

Clinical Assessment of Blood Glucose Homeostasis in Horses: Comparison of a Continuous Glucose Monitoring System with a Combined Intravenous Glucose and Insulin Test Protocol

Author keywords

Combined glucose insulin test; Continuous interstitial glucose monitor; Insulin resistance; Laminitis

Indexed keywords

INSULIN;

EID: 78651251705     PISSN: 08916640     EISSN: 19391676     Source Type: Journal    
DOI: 10.1111/j.1939-1676.2010.0643.x     Document Type: Article
Times cited : (12)

References (12)
  • 1
    • 33646589602 scopus 로고    scopus 로고
    • Evaluation of genetic and metabolic predispositions and nutritional risk factors for pasture-associated laminitis in ponies
    • Treiber KH, Kronfeld DS, Hess TM, et al. Evaluation of genetic and metabolic predispositions and nutritional risk factors for pasture-associated laminitis in ponies. J Am Vet Med Assoc 2006;228:1538-1545.
    • (2006) J Am Vet Med Assoc , vol.228 , pp. 1538-1545
    • Treiber, K.H.1    Kronfeld, D.S.2    Hess, T.M.3
  • 3
    • 77951913887 scopus 로고    scopus 로고
    • Type 2 diabetes mellitus with pancreatic β cell dysfunction in 3 horses confirmed with minimal model analysis
    • Durham AE, Hughes KJ, Cottle HJ, et al. Type 2 diabetes mellitus with pancreatic β cell dysfunction in 3 horses confirmed with minimal model analysis. Equine Vet J 2009;41:924-929.
    • (2009) Equine Vet J , vol.41 , pp. 924-929
    • Durham, A.E.1    Hughes, K.J.2    Cottle, H.J.3
  • 4
    • 64549135870 scopus 로고    scopus 로고
    • Characterization of hypertriglyceridemia and response to treatment with insulin in horses, ponies, and donkeys
    • J Am Vet Med Assoc
    • Waitt LH, Cebra CK. Characterization of hypertriglyceridemia and response to treatment with insulin in horses, ponies, and donkeys: 44 cases (1995-2005). J Am Vet Med Assoc 2009;234:915-919.
    • (2009) 44 cases (1995-2005) , vol.234 , pp. 915-919
    • Waitt, L.H.1    Cebra, C.K.2
  • 5
    • 0030558860 scopus 로고    scopus 로고
    • Hyperglycemia/hyperinsulinemia after feeding a meal of grain to young horses with osteochondritis dissecans (OCD) lesions
    • Ralston SL. Hyperglycemia/hyperinsulinemia after feeding a meal of grain to young horses with osteochondritis dissecans (OCD) lesions. Pferdeheilkunde 1996;12:320-322.
    • (1996) Pferdeheilkunde , vol.12 , pp. 320-322
    • Ralston, S.L.1
  • 6
    • 27744585068 scopus 로고    scopus 로고
    • Physiologic assessment of blood glucose homeostasis via combined intravenous glucose and insulin testing in horses
    • Eiler H, Frank N, Andrews FM, et al. Physiologic assessment of blood glucose homeostasis via combined intravenous glucose and insulin testing in horses. Am J Vet Res 2005;66:1598-1604.
    • (2005) Am J Vet Res , vol.66 , pp. 1598-1604
    • Eiler, H.1    Frank, N.2    Andrews, F.M.3
  • 7
    • 0141763636 scopus 로고    scopus 로고
    • Evaluation of a continuous glucose monitoring system for use in dogs, cats, and horses
    • Wiedmeyer CE, Johnson PJ, Cohn LA, et al. Evaluation of a continuous glucose monitoring system for use in dogs, cats, and horses. J Am Vet Med Assoc 2003;223:987-992.
    • (2003) J Am Vet Med Assoc , vol.223 , pp. 987-992
    • Wiedmeyer, C.E.1    Johnson, P.J.2    Cohn, L.A.3
  • 8
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LIK. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-268.
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.K.1
  • 9
    • 33644875792 scopus 로고    scopus 로고
    • Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor
    • Diabetes Care
    • Garg S, Zisser H, Schwartz S, et al. Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: A randomized controlled trial. Diabetes Care 2006;29:44-50.
    • (2006) A randomized controlled trial , vol.29 , pp. 44-50
    • Garg, S.1    Zisser, H.2    Schwartz, S.3
  • 10
    • 0033759474 scopus 로고    scopus 로고
    • Can interstitial glucose assessment replace blood glucose measurements?
    • Rebrin K, Steil GM. Can interstitial glucose assessment replace blood glucose measurements? Diabetes Technol Ther 2000;2:461-472.
    • (2000) Diabetes Technol Ther , vol.2 , pp. 461-472
    • Rebrin, K.1    Steil, G.M.2
  • 11
    • 73349099732 scopus 로고    scopus 로고
    • Evaluation of a novel real-time continuous glucose-monitoring system for use in cats
    • Moretti S, Tschuor F, Osto M, et al. Evaluation of a novel real-time continuous glucose-monitoring system for use in cats. J Vet Intern Med 2010;24:120-126.
    • (2010) J Vet Intern Med , vol.24 , pp. 120-126
    • Moretti, S.1    Tschuor, F.2    Osto, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.