메뉴 건너뛰기




Volumn 76, Issue 12, 2010, Pages 986-988

Electrical impedance tomography to guide ventilation in ALI-ARDS patients: A research tool for zealous physiologists or an imminent support for the real world intensivist?

Author keywords

[No Author keywords available]

Indexed keywords

ACUTE LUNG INJURY; ADULT RESPIRATORY DISTRESS SYNDROME; ARTIFICIAL VENTILATION; COMPUTER ASSISTED IMPEDANCE TOMOGRAPHY; DIAGNOSTIC ACCURACY; DISEASE SEVERITY; EDITORIAL; FORCED EXPIRATORY VOLUME; HUMAN; LUNG COMPLIANCE; LUNG MECHANICS; LUNG VENTILATION; LUNG VENTILATION DISTRIBUTION; NON INVASIVE PROCEDURE; POSITIVE END EXPIRATORY PRESSURE; PRESSURE VOLUME CURVE; TIDAL VOLUME; TREATMENT PLANNING; VENTILATOR INDUCED LUNG INJURY;

EID: 78651225486     PISSN: 03759393     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Editorial
Times cited : (9)

References (8)
  • 1
    • 0031819513 scopus 로고    scopus 로고
    • Acute respiratory distress syndrome caused by pulmonary and extrapulmonary disease. Different syndromes?
    • Gattinoni L, Pelosi P, Suter PM, Pedoto A, Vercesi P. Acute respiratory distress syndrome caused by pulmonary and extrapulmonary disease. Different syndromes? Am J Respir Crit Care Med 1998;158:3-11.
    • (1998) Am J Respir Crit Care Med , vol.158 , pp. 3-11
    • Gattinoni, L.1    Pelosi, P.2    Suter, P.M.3    Pedoto, A.4    Vercesi, P.5
  • 3
    • 0021844045 scopus 로고
    • Applied potential tomography: Possible clinical applications
    • Brown BH, Barber DC, Seagar AD. Applied potential tomography: possible clinical applications. Clin Phys Physiol Meas 1985;6:109-21.
    • (1985) Clin Phys Physiol Meas , vol.6 , pp. 109-121
    • Brown, B.H.1    Barber, D.C.2    Seagar, A.D.3
  • 4
    • 0029082881 scopus 로고
    • Changes in the thoracic impedance distribution under different ventilatory conditions
    • Hahn G, Sipinkova I, Baisch F, Hellige G. Changes in the thoracic impedance distribution under different ventilatory conditions. Physiol Mes 1995;16:A161-A173.
    • (1995) Physiol Mes , vol.16
    • Hahn, G.1    Sipinkova, I.2    Baisch, F.3    Hellige, G.4
  • 5
    • 77952425944 scopus 로고    scopus 로고
    • Impedance tomography as a new monitoring technique
    • Muders Th, Luepschen H, Putensen Ch. Impedance tomography as a new monitoring technique. Curr Opin Crit Care 2010;16:269-75.
    • (2010) Curr Opin Crit Care , vol.16 , pp. 269-275
    • Muders, T.1    Luepschen, H.2    Putensen, C.3
  • 6
    • 34249092005 scopus 로고    scopus 로고
    • Electrical impedance tomography guided ventilation therapy
    • Putensen Ch, Wrigge H, Zinserling J Electrical impedance tomography guided ventilation therapy. Curr Opin Crit Care 2007;13:344-50.
    • (2007) Curr Opin Crit Care , vol.13 , pp. 344-350
    • Putensen, C.1    Wrigge, H.2    Zinserling, J.3
  • 7
    • 78651255186 scopus 로고    scopus 로고
    • Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome, assessed by electric impedance tomography
    • Lowhagen K, Lundin S, Stenqvist O. Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome, assessed by electric impedance tomography. Minerva Anestesiol 2010;76.
    • (2010) Minerva Anestesiol , pp. 76
    • Lowhagen, K.1    Lundin, S.2    Stenqvist, O.3
  • 8
    • 0029047924 scopus 로고
    • Effects of positive end-expiratory pressure on regional distribution of tidal volume and recruitment in adult respiratory distress syndrome
    • Gattinoni L, Pelosi P, Crotti S, Valenza F. Effects of positive end-expiratory pressure on regional distribution of tidal volume and recruitment in adult respiratory distress syndrome. Am J Respir Crit Care Med 1995;151:1807-14.
    • (1995) Am J Respir Crit Care Med , vol.151 , pp. 1807-1814
    • Gattinoni, L.1    Pelosi, P.2    Crotti, S.3    Valenza, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.