메뉴 건너뛰기




Volumn 238, Issue , 2010, Pages

Beer-lambert law along non-linear mean light pathways for the rational analysis of Photoplethysmography

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; CARDIOVASCULAR SYSTEM; MACHINE DESIGN; NONINVASIVE MEDICAL PROCEDURES; OXIMETERS; TISSUE;

EID: 78651110787     PISSN: 17426588     EISSN: 17426596     Source Type: Conference Proceeding    
DOI: 10.1088/1742-6596/238/1/012061     Document Type: Conference Paper
Times cited : (22)

References (13)
  • 1
    • 0021797791 scopus 로고    scopus 로고
    • Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation
    • Dorlas J C and J A Nijboer Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation Br J Anaesth 57 524-30 May 1985
    • Br J Anaesth , vol.57 , pp. 524-530
    • Dorlas, J.C.1    Nijboer, J.A.2
  • 2
    • 0025957281 scopus 로고    scopus 로고
    • Photoplethysmography. Part 1. Comparison with laser Doppler flowmetry
    • Lindberg L G, et al Photoplethysmography. Part 1. Comparison with laser Doppler flowmetry Med Biol Eng Comput 29 40-7 Jan 1991
    • Med Biol Eng Comput , vol.29 , pp. 40-47
    • Lindberg, L.G.1
  • 3
    • 0019788635 scopus 로고    scopus 로고
    • Photoelectric plethysmography-some fundamental aspects of the reflection and transmission method
    • Nijboer J A, et al Photoelectric plethysmography-some fundamental aspects of the reflection and transmission method Clin Phys Physiol Meas 2 205-15 Aug 1981
    • Clin Phys Physiol Meas , vol.2 , Issue.3 , pp. 205-215
    • Nijboer, J.A.1
  • 4
    • 0031076227 scopus 로고    scopus 로고
    • A New Family of Sensors for Pulse Oximetry
    • Kästle S, et al 1997 A New Family of Sensors for Pulse Oximetry Hewlett-Packard J. Article 7
    • (1997) Hewlett-Packard J.
    • Kästle, S.1
  • 6
    • 0039075727 scopus 로고
    • Can Quantum-Mechanical Description of Physical Reality be Considered Complete?
    • Bohr N 1935 Can Quantum-Mechanical Description of Physical Reality be Considered Complete? Phys. Rev. 48 696-696
    • (1935) Phys. Rev. , vol.48 , Issue.8 , pp. 696-696
    • Bohr, N.1
  • 7
    • 33947385649 scopus 로고
    • Can Quantum-Mechanical Description of Physical Reality Be Considered Complete?
    • Einstein A, et al 1935 Can Quantum-Mechanical Description of Physical Reality Be Considered Complete? Phys. Rev. 47 777-780
    • (1935) Phys. Rev. , vol.47 , Issue.10 , pp. 777-780
    • Einstein, A.1
  • 8
    • 0024786530 scopus 로고
    • Monte Carlo modeling of light propagation in highly scattering tissues-II: Comparison with measurements in phantoms
    • Flock S T, et al 1989 Monte Carlo modeling of light propagation in highly scattering tissues-II: Comparison with measurements in phantoms IEEE Trans. Bio-Medical Eng. 36 1169-73
    • (1989) IEEE Trans. Bio-Medical Eng. , vol.36 , Issue.12 , pp. 1169-1173
    • Flock, S.T.1
  • 9
    • 0343735345 scopus 로고    scopus 로고
    • Light scattering study of tissues
    • Tuchin V V 1997 Light scattering study of tissues Phys.-Uspekhi 40 495-515
    • (1997) Phys.-Uspekhi , vol.40 , Issue.5 , pp. 495-515
    • Tuchin, V.V.1
  • 11
    • 0024834340 scopus 로고
    • Monte Carlo modeling of light propagation in highly scattering tissue-I: Model predictions and comparison with diffusion theory
    • Flock S T, et al 1989 Monte Carlo modeling of light propagation in highly scattering tissue-I: Model predictions and comparison with diffusion theory IEEE Trans. Bio-Medical Eng. 36 1162-8
    • (1989) IEEE Trans. Bio-Medical Eng. , vol.36 , Issue.12 , pp. 1162-1168
    • Flock, S.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.