메뉴 건너뛰기




Volumn 8, Issue , 2011, Pages

Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CORRELATION ANALYSIS; EVALUATION; GENETIC STRAIN; GENETIC VARIABILITY; GREECE; HIV TEST; HUMAN IMMUNODEFICIENCY VIRUS 1; INTERMETHOD COMPARISON; NONHUMAN; PERFORMANCE; QUANTITATIVE ANALYSIS; VIRUS LOAD; VIRUS STRAIN; ANALYTICAL EQUIPMENT; CLASSIFICATION; GENETICS; GENOTYPE; HUMAN; HUMAN IMMUNODEFICIENCY VIRUS INFECTION; ISOLATION AND PURIFICATION; METHODOLOGY; MOLECULAR DIAGNOSIS; PLASMA; VIROLOGY;

EID: 78651071856     PISSN: None     EISSN: 1743422X     Source Type: Journal    
DOI: 10.1186/1743-422X-8-10     Document Type: Article
Times cited : (11)

References (49)
  • 1
    • 0028874048 scopus 로고
    • Rapid turnover of plasma virions and CD4 lymphocytes in HIV-1 infection
    • 10.1038/373123a0. 7816094
    • Rapid turnover of plasma virions and CD4 lymphocytes in HIV-1 infection. DD Ho AU Neumann AS Perelson W Chen JM Leonard M Markowitz, Nature 1995 373 123 126 10.1038/373123a0 7816094
    • (1995) Nature , vol.373 , pp. 123-126
    • Ho, D.D.1    Neumann, A.U.2    Perelson, A.S.3    Chen, W.4    Leonard, J.M.5    Markowitz, M.6
  • 3
    • 0035251732 scopus 로고    scopus 로고
    • Plasma viral load testing in the management of HIV infection
    • 495-486. 11272298
    • Plasma viral load testing in the management of HIV infection. E Mylonakis M Paliou JD Rich, Am Fam Physician 2001 63 483 490 495-486 11272298
    • (2001) Am Fam Physician , vol.63 , pp. 483-490
    • Mylonakis, E.1    Paliou, M.2    Rich, J.D.3
  • 4
    • 0242285642 scopus 로고    scopus 로고
    • HIV update. Diagnostic tests and markers of disease progression and response to therapy
    • 14569811
    • HIV update. Diagnostic tests and markers of disease progression and response to therapy. M Zhang J Versalovic, Am J Clin Pathol 2002 118 Suppl 26 32 14569811
    • (2002) Am J Clin Pathol , vol.118 , Issue.SUPPL. , pp. 26-32
    • Zhang, M.1    Versalovic, J.2
  • 5
    • 52749083531 scopus 로고    scopus 로고
    • British HIV Association Guidelines for the treatment of HIV-1-infected adults with antiretroviral therapy 2008
    • 10.1111/j.1468-1293.2008.00636.x. 18826546
    • British HIV Association Guidelines for the treatment of HIV-1-infected adults with antiretroviral therapy 2008. BG Gazzard, HIV Med 2008 9 563 608 10.1111/j.1468-1293.2008.00636.x 18826546
    • (2008) HIV Med , vol.9 , pp. 563-608
    • Gazzard, B.G.1
  • 6
    • 42949105511 scopus 로고    scopus 로고
    • Updated antiretroviral treatment guidelines from DHHS and EACS
    • 18399008
    • Updated antiretroviral treatment guidelines from DHHS and EACS. C del Rio, AIDS Clin Care 2008 20 7 18399008
    • (2008) AIDS Clin Care , vol.20 , pp. 7
    • Del Rio, C.1
  • 7
    • 0030815923 scopus 로고    scopus 로고
    • A branched DNA signal amplification assay for quantification of nucleic acid targets below 100 molecules/ml
    • 10.1093/nar/25.15.2979. 9224596
    • A branched DNA signal amplification assay for quantification of nucleic acid targets below 100 molecules/ml. ML Collins B Irvine D Tyner E Fine C Zayati C Chang T Horn D Ahle J Detmer LP Shen,, et al. Nucleic Acids Res 1997 25 2979 2984 10.1093/nar/25.15.2979 9224596
    • (1997) Nucleic Acids Res , vol.25 , pp. 2979-2984
    • Collins, M.L.1    Irvine, B.2    Tyner, D.3    Fine, E.4    Zayati, C.5    Chang, C.6    Horn, T.7    Ahle, D.8    Detmer, J.9    Shen, L.P.10
  • 9
  • 10
    • 0028069547 scopus 로고
    • Rapid and simple PCR assay for quantitation of human immunodeficiency virus type 1 RNA in plasma: Application to acute retroviral infection
    • 8150937
    • Rapid and simple PCR assay for quantitation of human immunodeficiency virus type 1 RNA in plasma: application to acute retroviral infection. J Mulder N McKinney C Christopherson J Sninsky L Greenfield S Kwok, J Clin Microbiol 1994 32 292 300 8150937
    • (1994) J Clin Microbiol , vol.32 , pp. 292-300
    • Mulder, J.1    McKinney, N.2    Christopherson, C.3    Sninsky, J.4    Greenfield, L.5    Kwok, S.6
  • 13
    • 0033775615 scopus 로고    scopus 로고
    • Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays
    • 10.1677/jme.0.0250169. 11013345
    • Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays. SA Bustin, J Mol Endocrinol 2000 25 169 193 10.1677/jme.0.0250169 11013345
    • (2000) J Mol Endocrinol , vol.25 , pp. 169-193
    • Bustin, S.A.1
  • 14
    • 24944534978 scopus 로고    scopus 로고
    • Real-time PCR for mRNA quantitation
    • 10.2144/05391RV01. 16060372
    • Real-time PCR for mRNA quantitation. ML Wong JF Medrano, Biotechniques 2005 39 75 85 10.2144/05391RV01 16060372
    • (2005) Biotechniques , vol.39 , pp. 75-85
    • Wong, M.L.1    Medrano, J.F.2
  • 15
    • 0033769416 scopus 로고    scopus 로고
    • Genetic diversity of HIV-1: The moving target
    • 11086856
    • Genetic diversity of HIV-1: the moving target. M Peeters PM Sharp, Aids 2000 14 Suppl 3 129 140 11086856
    • (2000) Aids , vol.14 , Issue.SUPPL. 3 , pp. 19129-140
    • Peeters, M.1    Sharp, P.M.2
  • 18
    • 35348823156 scopus 로고    scopus 로고
    • Human immunodeficiency virus type 1 (HIV-1) plasma load discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR Version 1.5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 assays
    • 10.1128/JCM.00973-07. 17715371
    • Human immunodeficiency virus type 1 (HIV-1) plasma load discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR Version 1.5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 assays. F Damond B Roquebert A Benard G Collin M Miceli P Yeni F Brun-Vezinet D Descamps, J Clin Microbiol 2007 45 3436 3438 10.1128/JCM.00973-07 17715371
    • (2007) J Clin Microbiol , vol.45 , pp. 3436-3438
    • Damond, F.1    Roquebert, B.2    Benard, A.3    Collin, G.4    Miceli, M.5    Yeni, P.6    Brun-Vezinet, F.7    Descamps, D.8
  • 20
    • 23744440598 scopus 로고    scopus 로고
    • Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT
    • 10.1128/JCM.43.8.3860-3868.2005. 16081923
    • Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT. P Swanson C de Mendoza Y Joshi A Golden RL Hodinka V Soriano SG Devare J Hackett Jr, J Clin Microbiol 2005 43 3860 3868 10.1128/JCM.43.8.3860-3868.2005 16081923
    • (2005) J Clin Microbiol , vol.43 , pp. 3860-3868
    • Swanson, P.1    De Mendoza, C.2    Joshi, Y.3    Golden, A.4    Hodinka, R.L.5    Soriano, V.6    Devare, S.G.7    Hackett Jr., J.8
  • 21
    • 35648990433 scopus 로고    scopus 로고
    • A RealTime HIV-1 viral load assay for automated quantitation of HIV-1 RNA in genetically diverse group M subtypes A-H, group O and group N samples
    • 10.1016/j.jviromet.2007.07.003. 17707519
    • A RealTime HIV-1 viral load assay for automated quantitation of HIV-1 RNA in genetically diverse group M subtypes A-H, group O and group N samples. N Tang S Huang J Salituro WB Mak G Cloherty J Johanson YH Li G Schneider J Robinson J Hackett,, et al. J Virol Methods 2007 146 236 245 10.1016/j.jviromet.2007.07.003 17707519
    • (2007) J Virol Methods , vol.146 , pp. 236-245
    • Tang, N.1    Huang, S.2    Salituro, J.3    Mak, W.B.4    Cloherty, G.5    Johanson, J.6    Li, Y.H.7    Schneider, G.8    Robinson, J.9    Hackett, J.10
  • 22
    • 33748879967 scopus 로고    scopus 로고
    • Performance of the automated Abbott RealTime HIV-1 assay on a genetically diverse panel of specimens from London: Comparison to VERSANT HIV-1 RNA 3.0, AMPLICOR HIV-1 MONITOR v1.5, and LCx HIV RNA Quantitative assays
    • 10.1016/j.jviromet.2006.06.010. 16876263
    • Performance of the automated Abbott RealTime HIV-1 assay on a genetically diverse panel of specimens from London: comparison to VERSANT HIV-1 RNA 3.0, AMPLICOR HIV-1 MONITOR v1.5, and LCx HIV RNA Quantitative assays. P Swanson V Holzmayer S Huang P Hay A Adebiyi P Rice K Abravaya S Thamm SG Devare J Hackett Jr, J Virol Methods 2006 137 184 192 10.1016/j.jviromet.2006.06.010 16876263
    • (2006) J Virol Methods , vol.137 , pp. 184-192
    • Swanson, P.1    Holzmayer, V.2    Huang, S.3    Hay, P.4    Adebiyi, A.5    Rice, P.6    Abravaya, K.7    Thamm, S.8    Devare, S.G.9    Hackett Jr., J.10
  • 23
    • 67650021214 scopus 로고    scopus 로고
    • Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays
    • 10.1128/JCM.01761-08. 19420172
    • Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays. LE Scott LD Noble J Moloi L Erasmus WD Venter W Stevens, J Clin Microbiol 2009 47 2209 2217 10.1128/JCM.01761-08 19420172
    • (2009) J Clin Microbiol , vol.47 , pp. 2209-2217
    • Scott, L.E.1    Noble, L.D.2    Moloi, J.3    Erasmus, L.4    Venter, W.D.5    Stevens, W.6
  • 24
    • 14744306436 scopus 로고
    • Simultaneous amplification and detection of specific DNA sequences
    • 10.1038/nbt0492-413
    • Simultaneous amplification and detection of specific DNA sequences. R Higuchi G Dollinger PS Walsh R Griffith, Biotechnology (NY) 1992 10 413 417 10.1038/nbt0492-413
    • (1992) Biotechnology (NY) , vol.10 , pp. 413-417
    • Higuchi, R.1    Dollinger, G.2    Walsh, P.S.3    Griffith, R.4
  • 26
    • 30644456415 scopus 로고    scopus 로고
    • Evaluation of the clinical sensitivity for the quantification of human immunodeficiency virus type 1 RNA in plasma: Comparison of the new COBAS TaqMan HIV-1 with three current HIV-RNA assays - LCx HIV RNA quantitative, VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 Monitor v1.5
    • 10.1016/j.jviromet.2005.07.014. 16194575
    • Evaluation of the clinical sensitivity for the quantification of human immunodeficiency virus type 1 RNA in plasma: Comparison of the new COBAS TaqMan HIV-1 with three current HIV-RNA assays - LCx HIV RNA quantitative, VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 Monitor v1.5. A Katsoulidou M Petrodaskalaki V Sypsa E Papachristou CG Anastassopoulou P Gargalianos A Karafoulidou M Lazanas T Kordossis A Andoniadou A Hatzakis, J Virol Methods 2006 131 168 174 10.1016/j.jviromet.2005.07.014 16194575
    • (2006) J Virol Methods , vol.131 , pp. 168-174
    • Katsoulidou, A.1    Petrodaskalaki, M.2    Sypsa, V.3    Papachristou, E.4    Anastassopoulou, C.G.5    Gargalianos, P.6    Karafoulidou, A.7    Lazanas, M.8    Kordossis, T.9    Andoniadou, A.10    Hatzakis, A.11
  • 27
    • 0035059676 scopus 로고    scopus 로고
    • Quantification of human immunodeficiency virus type 1 proviral load by a TaqMan real-time PCR assay
    • 10.1128/JCM.39.4.1303-1310.2001. 11283046
    • Quantification of human immunodeficiency virus type 1 proviral load by a TaqMan real-time PCR assay. N Desire A Dehee V Schneider C Jacomet C Goujon PM Girard W Rozenbaum JC Nicolas, J Clin Microbiol 2001 39 1303 1310 10.1128/JCM.39.4.1303-1310.2001 11283046
    • (2001) J Clin Microbiol , vol.39 , pp. 1303-1310
    • Desire, N.1    Dehee, A.2    Schneider, V.3    Jacomet, C.4    Goujon, C.5    Girard, P.M.6    Rozenbaum, W.7    Nicolas, J.C.8
  • 28
    • 0037289544 scopus 로고    scopus 로고
    • Comparison of TaqMan real-time PCR and p24 Elisa for quantification of in vitro HIV-1 replication
    • 10.1016/S0166-0934(02)00230-6. 12505631
    • Comparison of TaqMan real-time PCR and p24 Elisa for quantification of in vitro HIV-1 replication. SA Klein S Karsten B Ruster C Klebba M Pape OG Ottmann D Hoelzer WK Roth, J Virol Methods 2003 107 169 175 10.1016/S0166-0934(02) 00230-6 12505631
    • (2003) J Virol Methods , vol.107 , pp. 169-175
    • Klein, S.A.1    Karsten, S.2    Ruster, B.3    Klebba, C.4    Pape, M.5    Ottmann, O.G.6    Hoelzer, D.7    Roth, W.K.8
  • 29
    • 10744228049 scopus 로고    scopus 로고
    • New real-time reverse transcriptase-initiated PCR assay with single-copy sensitivity for human immunodeficiency virus type 1 RNA in plasma
    • 10.1128/JCM.41.10.4531-4536.2003. 14532178
    • New real-time reverse transcriptase-initiated PCR assay with single-copy sensitivity for human immunodeficiency virus type 1 RNA in plasma. S Palmer AP Wiegand F Maldarelli H Bazmi JM Mican M Polis RL Dewar A Planta S Liu JA Metcalf,, et al. J Clin Microbiol 2003 41 4531 4536 10.1128/JCM.41.10.4531-4536. 2003 14532178
    • (2003) J Clin Microbiol , vol.41 , pp. 4531-4536
    • Palmer, S.1    Wiegand, A.P.2    Maldarelli, F.3    Bazmi, H.4    Mican, J.M.5    Polis, M.6    Dewar, R.L.7    Planta, A.8    Liu, S.9    Metcalf, J.A.10
  • 30
    • 0034747327 scopus 로고    scopus 로고
    • TaqMan 5'-nuclease human immunodeficiency virus type 1 PCR assay with phage-packaged competitive internal control for high-throughput blood donor screening
    • 10.1128/JCM.39.12.4302-4308.2001. 11724836
    • TaqMan 5'-nuclease human immunodeficiency virus type 1 PCR assay with phage-packaged competitive internal control for high-throughput blood donor screening. C Drosten E Seifried WK Roth, J Clin Microbiol 2001 39 4302 4308 10.1128/JCM.39.12.4302-4308.2001 11724836
    • (2001) J Clin Microbiol , vol.39 , pp. 4302-4308
    • Drosten, C.1    Seifried, E.2    Roth, W.K.3
  • 34
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 2868172
    • Statistical methods for assessing agreement between two methods of clinical measurement. JM Bland DG Altman, Lancet 1986 1 307 310 2868172
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 35
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • 10.1191/096228099673819272. 10501650
    • Measuring agreement in method comparison studies. JM Bland DG Altman, Stat Methods Med Res 1999 8 135 160 10.1191/096228099673819272 10501650
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 36
    • 70349742777 scopus 로고    scopus 로고
    • Evaluation of the Abbott m2000rt RealTime HIV-1 assay with manual sample preparation compared with the ROCHE COBAS AmpliPrep/AMPLICOR HIV-1 MONITOR v1.5 using specimens from East Africa
    • 10.1016/j.jviromet.2009.08.013. 19729037
    • Evaluation of the Abbott m2000rt RealTime HIV-1 assay with manual sample preparation compared with the ROCHE COBAS AmpliPrep/AMPLICOR HIV-1 MONITOR v1.5 using specimens from East Africa. JA Crump LE Scott E Msuya AB Morrissey EE Kimaro JF Shao WS Stevens, J Virol Methods 2009 162 218 222 10.1016/j.jviromet. 2009.08.013 19729037
    • (2009) J Virol Methods , vol.162 , pp. 218-222
    • Crump, J.A.1    Scott, L.E.2    Msuya, E.3    Morrissey, A.B.4    Kimaro, E.E.5    Shao, J.F.6    Stevens, W.S.7
  • 37
    • 33747200876 scopus 로고    scopus 로고
    • Comparison of the LCx human immunodeficiency virus (HIV) RNA quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan assays for quantitation of HIV type 1 RNA in plasma
    • 10.1128/JCM.00341-06. 16891517
    • Comparison of the LCx human immunodeficiency virus (HIV) RNA quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan assays for quantitation of HIV type 1 RNA in plasma. V Foulongne B Montes MN Didelot-Rousseau M Segondy, J Clin Microbiol 2006 44 2963 2966 10.1128/JCM.00341-06 16891517
    • (2006) J Clin Microbiol , vol.44 , pp. 2963-2966
    • Foulongne, V.1    Montes, B.2    Didelot-Rousseau, M.N.3    Segondy, M.4
  • 38
    • 65249107130 scopus 로고    scopus 로고
    • Comparison of the Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 test: Workflow, reliability, and direct costs
    • 10.1128/JCM.02231-08. 19193837
    • Comparison of the Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 test: workflow, reliability, and direct costs. CR Sloma JJ Germer TM Gerads JN Mandrekar PS Mitchell JD Yao, J Clin Microbiol 2009 47 889 895 10.1128/JCM.02231-08 19193837
    • (2009) J Clin Microbiol , vol.47 , pp. 889-895
    • Sloma, C.R.1    Germer, J.J.2    Gerads, T.M.3    Mandrekar, J.N.4    Mitchell, P.S.5    Yao, J.D.6
  • 39
    • 34447280788 scopus 로고    scopus 로고
    • Comparison of the Roche COBAS Amplicor Monitor, Roche COBAS Ampliprep/COBAS Taqman and Abbott RealTime Test assays for quantification of hepatitis C virus and HIV RNA
    • 10.1515/CCLM.2007.149. 17617038
    • Comparison of the Roche COBAS Amplicor Monitor, Roche COBAS Ampliprep/COBAS Taqman and Abbott RealTime Test assays for quantification of hepatitis C virus and HIV RNA. D Wolff A Gerritzen, Clin Chem Lab Med 2007 45 917 922 10.1515/CCLM.2007.149 17617038
    • (2007) Clin Chem Lab Med , vol.45 , pp. 917-922
    • Wolff, D.1    Gerritzen, A.2
  • 40
    • 0030763603 scopus 로고    scopus 로고
    • Effects of specimen collection, processing, and storage conditions on stability of human immunodeficiency virus type 1 RNA levels in plasma
    • 9350753
    • Effects of specimen collection, processing, and storage conditions on stability of human immunodeficiency virus type 1 RNA levels in plasma. CC Ginocchio XP Wang MH Kaplan G Mulligan D Witt JW Romano M Cronin R Carroll, J Clin Microbiol 1997 35 2886 2893 9350753
    • (1997) J Clin Microbiol , vol.35 , pp. 2886-2893
    • Ginocchio, C.C.1    Wang, X.P.2    Kaplan, M.H.3    Mulligan, G.4    Witt, D.5    Romano, J.W.6    Cronin, M.7    Carroll, R.8
  • 41
    • 0031965458 scopus 로고    scopus 로고
    • Stability of human immunodeficiency virus RNA in blood specimens as measured by a commercial PCR-based assay
    • 9466765
    • Stability of human immunodeficiency virus RNA in blood specimens as measured by a commercial PCR-based assay. K Sebire K McGavin S Land T Middleton C Birch, J Clin Microbiol 1998 36 493 498 9466765
    • (1998) J Clin Microbiol , vol.36 , pp. 493-498
    • Sebire, K.1    McGavin, K.2    Land, S.3    Middleton, T.4    Birch, C.5
  • 42
    • 46949096989 scopus 로고    scopus 로고
    • Comparison of the Abbott RealTime HIV-1 and HCV viral load assays with commercial competitor assays
    • 10.1586/14737159.8.4.369. 18598219
    • Comparison of the Abbott RealTime HIV-1 and HCV viral load assays with commercial competitor assays. M Schutten, Expert Rev Mol Diagn 2008 8 369 377 10.1586/14737159.8.4.369 18598219
    • (2008) Expert Rev Mol Diagn , vol.8 , pp. 369-377
    • Schutten, M.1
  • 44
    • 34250210715 scopus 로고    scopus 로고
    • Impaired quantification of plasma HIV-1 RNA with a commercialized real-time PCR assay in a couple of HIV-1-infected individuals
    • 10.1016/j.jcv.2007.04.007. 17532257
    • Impaired quantification of plasma HIV-1 RNA with a commercialized real-time PCR assay in a couple of HIV-1-infected individuals. P Colson C Solas J Moreau A Motte M Henry C Tamalet, J Clin Virol 2007 39 226 229 10.1016/j.jcv.2007.04.007 17532257
    • (2007) J Clin Virol , vol.39 , pp. 226-229
    • Colson, P.1    Solas, C.2    Moreau, J.3    Motte, A.4    Henry, M.5    Tamalet, C.6
  • 45
    • 0026518911 scopus 로고
    • Human immunodeficiency virus type 1 quasispecies in vivo and ex vivo
    • 1600752
    • Human immunodeficiency virus type 1 quasispecies in vivo and ex vivo. S Wain-Hobson, Curr Top Microbiol Immunol 1992 176 181 193 1600752
    • (1992) Curr Top Microbiol Immunol , vol.176 , pp. 181-193
    • Wain-Hobson, S.1
  • 46
    • 33847205778 scopus 로고    scopus 로고
    • Evaluation of performance across the dynamic range of the Abbott RealTime HIV-1 assay as compared to VERSANT HIV-1 RNA 3.0 and AMPLICOR HIV-1 MONITOR v1.5 using serial dilutions of 39 group M and O viruses
    • 10.1016/j.jviromet.2006.11.026. 17184853
    • Evaluation of performance across the dynamic range of the Abbott RealTime HIV-1 assay as compared to VERSANT HIV-1 RNA 3.0 and AMPLICOR HIV-1 MONITOR v1.5 using serial dilutions of 39 group M and O viruses. P Swanson S Huang K Abravaya C de Mendoza V Soriano SG Devare J Hackett Jr, J Virol Methods 2007 141 49 57 10.1016/j.jviromet.2006.11.026 17184853
    • (2007) J Virol Methods , vol.141 , pp. 49-57
    • Swanson, P.1    Huang, S.2    Abravaya, K.3    De Mendoza, C.4    Soriano, V.5    Devare, S.G.6    Hackett Jr., J.7
  • 47
    • 33846543809 scopus 로고    scopus 로고
    • Comparison of four commercial quantitative HIV-1 assays for viral load monitoring in clinical daily routine
    • 10.1515/CCLM.2007.008. 17243923
    • Comparison of four commercial quantitative HIV-1 assays for viral load monitoring in clinical daily routine. P Braun R Ehret F Wiesmann F Zabbai M Knickmann R Kuhn S Thamm G Warnat H Knechten, Clin Chem Lab Med 2007 45 93 99 10.1515/CCLM.2007.008 17243923
    • (2007) Clin Chem Lab Med , vol.45 , pp. 93-99
    • Braun, P.1    Ehret, R.2    Wiesmann, F.3    Zabbai, F.4    Knickmann, M.5    Kuhn, R.6    Thamm, S.7    Warnat, G.8    Knechten, H.9
  • 48
    • 34250673163 scopus 로고    scopus 로고
    • Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA
    • 10.1128/JCM.02385-06. 17409216
    • Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA. M Schutten D Peters NK Back M Beld K Beuselinck V Foulongne AM Geretti L Pandiani C Tiemann HG Niesters, J Clin Microbiol 2007 45 1712 1717 10.1128/JCM.02385-06 17409216
    • (2007) J Clin Microbiol , vol.45 , pp. 1712-1717
    • Schutten, M.1    Peters, D.2    Back, N.K.3    Beld, M.4    Beuselinck, K.5    Foulongne, V.6    Geretti, A.M.7    Pandiani, L.8    Tiemann, C.9    Niesters, H.G.10
  • 49
    • 66149147547 scopus 로고    scopus 로고
    • Impact of discrepancies between the Abbott RrealTime and cobas TaqMan assays for quantification of human immunodeficiency virus type 1 group M non-B subtypes
    • 10.1128/JCM.02134-08. 19297599
    • Impact of discrepancies between the Abbott RrealTime and cobas TaqMan assays for quantification of human immunodeficiency virus type 1 group M non-B subtypes. M Wirden R Tubiana F Marguet I Leroy A Simon M Bonmarchand Z Ait-Arkoub R Murphy AG Marcelin C Katlama V Calvez, J Clin Microbiol 2009 47 1543 1545 10.1128/JCM.02134-08 19297599
    • (2009) J Clin Microbiol , vol.47 , pp. 1543-1545
    • Wirden, M.1    Tubiana, R.2    Marguet, F.3    Leroy, I.4    Simon, A.5    Bonmarchand, M.6    Ait-Arkoub, Z.7    Murphy, R.8    Marcelin, A.G.9    Katlama, C.10    Calvez, V.11


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.