Volumn 26, Issue 1, 2011, Pages 385-393

Included angle selection of V-shape insulator string for 750-kV compact transmission line

Author keywords

Compact transmission line; finite element model; loading experiment; stress and swing; V shape insulator string

Indexed keywords

COMPACT TRANSMISSION LINES; EXPERIMENTAL DATA; FINITE-ELEMENT MODELS; INSULATOR STRING; LOADING EXPERIMENT; MECHANICAL PERFORMANCE; NEW SOLUTIONS; PORCELAIN INSULATORS; V-SHAPE;

EID: 78650919718     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2010.2068567     Document Type: Article
Times cited : (11)

References (15)
  • 4
    • 78650867214 scopus 로고    scopus 로고
    • Study on loading characteristics of V-shape composite insulator used in 330 kV compact line
    • Y. Bo, H. Lei, and W. Liming, "Study on loading characteristics of V-shape composite insulator used in 330 kV compact line," Proc. CSEE, vol. 25, no. 15, 2005.
    • (2005) Proc. CSEE , vol.25 , Issue.15
    • Bo, Y.1    Lei, H.2    Liming, W.3
  • 5
  • 6
    • 78650860031 scopus 로고    scopus 로고
    • Design and application of cup-tower for center-phase with v-string
    • Z. Quanjiang, B. Yongzhong, and Z. Peihua, "Design and application of cup-tower for center-phase with v-string," Shanxi Electric, vol. 5, pp. 53-58, 2003.
    • (2003) Shanxi Electric , vol.5 , pp. 53-58
    • Quanjiang, Z.1    Yongzhong, B.2    Peihua, Z.3
  • 8
    • 78650883478 scopus 로고    scopus 로고
    • Investigation on application of composite insulator for V-string
    • S. Dingshen, C.Wei, and W. Jin, "Investigation on application of composite insulator for V-string," Insulators Sure Arresters, vol. 201, no. 5, pp. 14-16, 2004.
    • (2004) Insulators Sure Arresters , vol.201 , Issue.5 , pp. 14-16
    • Dingshen, S.1    Wei, C.2    Jin, W.3
  • 9
    • 78650876789 scopus 로고    scopus 로고
    • Execution of prevention of ball head drop-out of V-shaped insulators on 500 kV compact type transmission lines
    • Y. Wenjun, L. Chuntian, and Z. Haijun, "Execution of prevention of ball head drop-out of V-shaped insulators on 500 kV compact type transmission lines," Elect. Power Construct., vol. 27, no. 7, pp. 8-10, 2006.
    • (2006) Elect. Power Construct. , vol.27 , Issue.7 , pp. 8-10
    • Wenjun, Y.1    Chuntian, L.2    Haijun, Z.3
  • 10
    • 78650884782 scopus 로고    scopus 로고
    • Analysis on the mechanism of V-shaped compound insulator chain s dropping on 500 kV compact transmission lines
    • C. Yu, "Analysis on the mechanism of V-shaped compound insulator chain s dropping on 500 kV compact transmission lines," Sci-Tech Inf. Develop. Econ., vol. 17, no. 36, pp. 254-255, 2007.
    • (2007) Sci-Tech Inf. Develop. Econ. , vol.17 , Issue.36 , pp. 254-255
    • Yu, C.1
  • 12
    • 78650892718 scopus 로고    scopus 로고
    • Design and calculation for V-shape insulator strings
    • L. Xujun and H. Zhaofeng, "Design and calculation for V - shape insulator strings," Shandong Electric Power, vol. 116, no. 6, pp. 12-14, 2000.
    • (2000) Shandong Electric Power , vol.116 , Issue.6 , pp. 12-14
    • Xujun, L.1    Zhaofeng, H.2
  • 13
    • 78650922941 scopus 로고    scopus 로고
    • Mechannical verify curve of V-shape insulator strings
    • N. Haiyun, "Mechannical verify curve of V-shape insulator strings," Yunnan Elect. Power, vol. 28, no. 1, pp. 10-11, 2000.
    • (2000) Yunnan Elect. Power , vol.28 , Issue.1 , pp. 10-11
    • Haiyun, N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.