Volumn 30, Issue 1, 2011, Pages 22-27

Simultaneous dual frequency 1H and 19F open coil imaging of arthritic rabbit knee at 3T

Author keywords

Fluorine imaging; magnetic resonance imaging (MRI); multifrequency; radio frequency (RF) coil design; targeted nanoparticle contrast agent

Indexed keywords

BIO-MOLECULAR; COIL GEOMETRIES; CONTRAST AGENT; DUAL FREQUENCY; ELECTRICAL EVALUATIONS; FIELD STRENGTHS; IN-VIVO; LEVEL PROCESS; MOLECULAR IMAGING; MRI SCANNERS; MULTIFREQUENCY; OPERATIONAL PARAMETERS; OPERATIONAL PROBLEMS; PHILIPS MEDICAL SYSTEMS; RABBIT KNEES; RADIO-FREQUENCY (RF) COIL DESIGN; RADIO-FREQUENCY COIL; RECEIVE MODE; RESONANCE TECHNIQUE; RF MEASUREMENTS; SIMULATION PROGRAM WITH INTEGRATED CIRCUIT EMPHASIS; TARGETED NANOPARTICLE; TECHNICAL DATABASE;

EID: 78650907868     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2010.2056689     Document Type: Article
Times cited : (33)

References (14)
  • 2
    • 66149138882 scopus 로고    scopus 로고
    • Noise figure limits for circular loop MR coils
    • May
    • A. Kumar, W. A. Edelstein, and P. A. Bottomley, "Noise figure limits for circular loop MR coils," Magn. Reson. Med., vol. 61, pp. 1201-9, May 2009.
    • (2009) Magn. Reson. Med. , vol.61 , pp. 1201-9
    • Kumar, A.1    Edelstein, W.A.2    Bottomley, P.A.3
  • 4
    • 38249017250 scopus 로고
    • A 64 MHz half-birdcage resonator for clinical imaging
    • D. Ballon, M. C. Graham, S. Miodownik, and J. A. Koutcher, "A 64 MHz half-birdcage resonator for clinical imaging," J. Magn. Reson., vol. 90, pp. 131-140, 1990.
    • (1990) J. Magn. Reson. , vol.90 , pp. 131-140
    • Ballon, D.1    Graham, M.C.2    Miodownik, S.3    Koutcher, J.A.4
  • 5
    • 0029347450 scopus 로고
    • A simple method to incorporate the effects of an RF shield into RF resonator analysis for MRI applications
    • Aug.
    • J. Jin, R. L. Magin, G. Shen, and T. Perkins, "A simple method to incorporate the effects of an RF shield into RF resonator analysis for MRI applications," IEEE Trans. Biomed. Eng., vol. 42, pp. 840-3, Aug. 1995.
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , pp. 840-3
    • Jin, J.1    Magin, R.L.2    Shen, G.3    Perkins, T.4
  • 10
    • 78650864647 scopus 로고    scopus 로고
    • ver. 5, Beige Bag Software, Ann Arbor MI
    • B2 Spice. ver. 5, Beige Bag Software, Ann Arbor, MI.
    • B2 Spice
  • 14
    • 0032239369 scopus 로고    scopus 로고
    • Surface and gradiometer coils near a conducting body: The lift-off effect
    • B. H. Suits, A. N. Garroway, and J. B. Miller, "Surface and gradiometer coils near a conducting body: The lift-off effect," J. Magn. Reson., vol. 135, pp. 373-9, 1998.
    • (1998) J. Magn. Reson. , vol.135 , pp. 373-9
    • Suits, B.H.1    Garroway, A.N.2    Miller, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.