Volumn 25, Issue 4, 2011, Pages 1926-1934

Contribution of cocktail of polypropylene and steel fibres in improving the behaviour of high strength concrete subjected to high temperature

Author keywords

Concrete; Ductility; Fibres cocktail; Mass loss; Modulus of elasticity; Polypropylene fibres; Porosity; Steel fibres; Strength; Temperature

Indexed keywords

FIBRES COCKTAIL; MASS LOSS; MODULUS OF ELASTICITY; POLYPROPYLENE FIBRES; STEEL FIBRES; STRENGTH;

EID: 78650881507     PISSN: 09500618     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.conbuildmat.2010.11.064     Document Type: Article
Times cited : (170)

References (36)
  • 1
    • 0003566904 scopus 로고
    • Technical University of Denmark, Institute of Building Design, Report 166
    • Hertz K. Heat induced explosion of dense concretes, Technical University of Denmark, Institute of Building Design, Report 166; 1984.
    • (1984) Heat Induced Explosion of Dense Concretes
    • Hertz, K.1
  • 2
    • 0023043892 scopus 로고
    • Research at imperial college on the effect of elevated temperatures on concrete
    • G.A. Khoury, and P.J.E. Sullivan Research at imperial college on the effect of elevated temperatures on concrete Fire Safety J 13 1988 68 72
    • (1988) Fire Safety J , vol.13 , pp. 68-72
    • Khoury, G.A.1    Sullivan, P.J.E.2
  • 4
    • 0027559487 scopus 로고
    • Spalling of high-strength silica fume concrete in fire
    • G. Sanjayan, and L. Stocks Spalling of high-strength silica fume concrete in fire ACI Mater J 90 1993 170 173
    • (1993) ACI Mater J , vol.90 , pp. 170-173
    • Sanjayan, G.1    Stocks, L.2
  • 6
    • 59849089609 scopus 로고    scopus 로고
    • Permeability of high-performance concrete subjected to elevated temperature (600 °c)
    • N.A. Noumowé, R. Siddique, and G. Debicki Permeability of high-performance concrete subjected to elevated temperature (600 °C) Constr Build Mater 23 2009 1855 1861
    • (2009) Constr Build Mater , vol.23 , pp. 1855-1861
    • Noumowé, N.A.1    Siddique, R.2    Debicki, G.3
  • 7
    • 0002390173 scopus 로고    scopus 로고
    • Effects of elevated temperature exposure on heating characteristics, spalling, and residual properties of high performance concrete
    • L.T. Phan, J.R. Lawson, and F.L. Davis Effects of elevated temperature exposure on heating characteristics, spalling, and residual properties of high performance concrete Mater Struct 34 2001 83 91
    • (2001) Mater Struct , vol.34 , pp. 83-91
    • Phan, L.T.1    Lawson, J.R.2    Davis, F.L.3
  • 9
    • 35348854970 scopus 로고    scopus 로고
    • Expérimental and numérical studies of thermo-hydrous tranfers in concrete exposed to high temperature
    • T.M. Kanéma, M.V.G. De Morais, A. Noumowé, J.-L. Gallias, and R. Cabrillac Expérimental and numérical studies of thermo-hydrous tranfers in concrete exposed to high temperature Heat Mass Transfer 44 2007 149 164
    • (2007) Heat Mass Transfer , vol.44 , pp. 149-164
    • Kanéma, T.M.1    De Morais, M.V.G.2    Noumowé, A.3    Gallias, J.-L.4    Cabrillac, R.5
  • 10
    • 78650871280 scopus 로고    scopus 로고
    • Fire resistance of concrete enclosures. Work package 1: Data collection, work package 2: Spalling categories
    • ArupFire, HSE
    • ArupFire, HSE, Fire resistance of concrete enclosures. Work package 1: data collection, work package 2: spalling categories. Rev B; 2005.
    • (2005) Rev B
  • 14
    • 0033101616 scopus 로고    scopus 로고
    • The "chunnel" fire. I: Chemoplastic softening in rapidly heated concrete
    • F.-J. Ulm, O. Coussy, and Z.P. Bazant The "Chunnel" fire. I: chemoplastic softening in rapidly heated concrete J Eng Mech March 1999 272 282
    • (1999) J Eng Mech , Issue.MARCH , pp. 272-282
    • Ulm, F.-J.1    Coussy, O.2    Bazant, Z.P.3
  • 16
    • 0035477318 scopus 로고    scopus 로고
    • High-temperature behavior of HPC with polypropylene fibres-from spalling to microstructure
    • P. Kalifa, G. Chene, and C. Galle High-temperature behavior of HPC with polypropylene fibres-from spalling to microstructure Cement Concrete Res 31 2001 1487 1499
    • (2001) Cement Concrete Res , vol.31 , pp. 1487-1499
    • Kalifa, P.1    Chene, G.2    Galle, C.3
  • 17
    • 0043284265 scopus 로고    scopus 로고
    • Temperature distribution and mechanical properties of high-strength silica fume concrete at temperatures up to 200 °c
    • N. Noumowé Temperature distribution and mechanical properties of high-strength silica fume concrete at temperatures up to 200 °C ACI Mater J 2003 326 330 [Title no 100-M39]
    • (2003) ACI Mater J , pp. 326-330
    • Noumowé, N.1
  • 18
    • 32644439206 scopus 로고    scopus 로고
    • On residual strength of high-performance concrete with and without polypropylene fibres at elevates temperatures
    • J. Xiao, and H. Falkner On residual strength of high-performance concrete with and without polypropylene fibres at elevates temperatures Fire Safety J 41 2006 115 121
    • (2006) Fire Safety J , vol.41 , pp. 115-121
    • Xiao, J.1    Falkner, H.2
  • 19
    • 33646106555 scopus 로고    scopus 로고
    • How do polypropylene fibers improve the spalling behavior of in-situ concrete?
    • M. Zeiml, D. Leithner, R. Lackner, and H. Mang How do polypropylene fibers improve the spalling behavior of in-situ concrete? Cement Concrete Res 36 2006 929 942
    • (2006) Cement Concrete Res , vol.36 , pp. 929-942
    • Zeiml, M.1    Leithner, D.2    Lackner, R.3    Mang, H.4
  • 20
    • 27744541894 scopus 로고    scopus 로고
    • Mechanical properties and microstruture of high strength concrete containing polypropylene fibres exposed to temperatures up to 200 °c
    • N.A. Noumowé Mechanical properties and microstruture of high strength concrete containing polypropylene fibres exposed to temperatures up to 200 °C Cement Concrete Res 35 2005 2192 2198
    • (2005) Cement Concrete Res , vol.35 , pp. 2192-2198
    • Noumowé, N.A.1
  • 21
    • 70349769172 scopus 로고    scopus 로고
    • Comparison of compressive and splitting tensile strength of high-strength concrete with and without polypropylene fibers heated to high temperatures
    • 10.1016/j.firesaf.2009.07.001
    • A. Behnood, and M. Ghandehari Comparison of compressive and splitting tensile strength of high-strength concrete with and without polypropylene fibers heated to high temperatures Fire Safety J 2009 10.1016/j.firesaf.2009.07.001
    • (2009) Fire Safety J
    • Behnood, A.1    Ghandehari, M.2
  • 22
    • 1242277254 scopus 로고    scopus 로고
    • Stress-strain for high strength concrete at elevated temperatures
    • F.-P. Cheng, V.K.R. Kodur, and T.-C. Wang Stress-strain for high strength concrete at elevated temperatures J Mater Civ Eng 16 2004 84 90
    • (2004) J Mater Civ Eng , vol.16 , pp. 84-90
    • Cheng, F.-P.1    Kodur, V.K.R.2    Wang, T.-C.3
  • 23
    • 33748753676 scopus 로고    scopus 로고
    • Effect of high temperatures on high performance steel fiber reinforced concrete
    • A. Lau, and M. Anson Effect of high temperatures on high performance steel fiber reinforced concrete Cement Concrete Res 36 2006 1698 1707
    • (2006) Cement Concrete Res , vol.36 , pp. 1698-1707
    • Lau, A.1    Anson, M.2
  • 26
    • 2142661794 scopus 로고    scopus 로고
    • Residual strength of hybrid-fiber reinforced high strength concrete after exposure to high temperature
    • B. Chen, and J. Liu Residual strength of hybrid-fiber reinforced high strength concrete after exposure to high temperature Cement Concrete Res 34 2004 1065 1069
    • (2004) Cement Concrete Res , vol.34 , pp. 1065-1069
    • Chen, B.1    Liu, J.2
  • 27
    • 10044299325 scopus 로고    scopus 로고
    • Compressive behavior of fiber reinforced high-performance concrete subjected to elevated temperatures
    • C.S. Poon, Z.H. Shui, and L. Lam Compressive behavior of fiber reinforced high-performance concrete subjected to elevated temperatures Cement Concrete Res 34 2004 2215 2222
    • (2004) Cement Concrete Res , vol.34 , pp. 2215-2222
    • Poon, C.S.1    Shui, Z.H.2    Lam, L.3
  • 28
    • 33645143846 scopus 로고    scopus 로고
    • Explosive spalling and residual mechanical properties of fiber-toughened high-performance concrete subjected to high temperatures
    • G.-F. Peng, W.-W. Yang, J. Zhao, Y.-F. Liu, S.-H. Bian, and L.-H. Zhao Explosive spalling and residual mechanical properties of fiber-toughened high-performance concrete subjected to high temperatures Cement Concrete Res 36 2006 723 727
    • (2006) Cement Concrete Res , vol.36 , pp. 723-727
    • Peng, G.-F.1    Yang, W.-W.2    Zhao, J.3    Liu, Y.-F.4    Bian, S.-H.5    Zhao, L.-H.6
  • 29
    • 33748746142 scopus 로고    scopus 로고
    • Effect of short fibers on residual permeability and mechanical properties of hybrid fibre reinforced high strength concrete after heat exposition
    • S.L. Suhaendi, and H. Takashi Effect of short fibers on residual permeability and mechanical properties of hybrid fibre reinforced high strength concrete after heat exposition Cement Concrete Res 36 2006 1672 1678
    • (2006) Cement Concrete Res , vol.36 , pp. 1672-1678
    • Suhaendi, S.L.1    Takashi, H.2
  • 30
    • 85013866047 scopus 로고    scopus 로고
    • A way to improve the behaviour of concrete at high temperature: Addition of a cocktail of polypropylene and steel fibres
    • Washington; 29 May-3 June
    • Pliya P, Beaucour A-L, Noumowé A. A way to improve the behaviour of concrete at high temperature: addition of a cocktail of polypropylene and steel fibres. In: International fib congress and PCI annual convention/ exhibition, Washington; 29 May-3 June 2010.
    • (2010) International Fib Congress and PCI Annual Convention/exhibition
    • Pliya, P.1    Beaucour, A.-L.2    Noumowé, A.3
  • 31
    • 38749125136 scopus 로고    scopus 로고
    • High temperature resistance of normal strength and autoclaved high strength mortars incorporated polypropylene and steel fibers
    • S. Aydin, H. Yazici, and B. Baradan High temperature resistance of normal strength and autoclaved high strength mortars incorporated polypropylene and steel fibers Constr Build Mater 22 2008 504 512
    • (2008) Constr Build Mater , vol.22 , pp. 504-512
    • Aydin, S.1    Yazici, H.2    Baradan, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.