메뉴 건너뛰기




Volumn 26, Issue 1, 2011, Pages 143-151

Hilbert-transform-based transient/intermittent earth fault detection in noneffectively grounded distribution systems

Author keywords

Direction detection; earth fault detection; instantaneous power; intermittent fault; transient fault

Indexed keywords

DIRECTION DETECTION; EARTH FAULT DETECTION; INSTANTANEOUS POWER; INTERMITTENT FAULT; TRANSIENT FAULT;

EID: 78650877897     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2010.2068578     Document Type: Article
Times cited : (115)

References (18)
  • 1
    • 36249018129 scopus 로고    scopus 로고
    • PSRC Working Group D15, Online]. Available
    • PSRC Working Group D15, High impedance fault detection technology, 1996. [Online]. Available: http://grouper.ieee.org/groups/td/ dist/documents/highz.pdf
    • (1996) High Impedance Fault Detection Technology
  • 2
    • 0007826387 scopus 로고
    • GEC Measurement, 3rd ed. Stafford U.K.: AREVA T&D
    • Protective Relay Application Guide, GEC Measurement, 3rd ed. Stafford, U.K.: AREVA T&D, 1987.
    • (1987) Protective Relay Application Guide
  • 3
    • 0025408431 scopus 로고
    • Unique aspects of distribution system harmonics due to high impedance ground faults
    • Apr.
    • D. I. Jeerings and J. R. Linders, "Unique aspects of distribution system harmonics due to high impedance ground faults," IEEE Trans. Power Del., vol. 5, no. 2, pp. 1086-1094, Apr. 1990.
    • (1990) IEEE Trans. Power Del. , vol.5 , Issue.2 , pp. 1086-1094
    • Jeerings, D.I.1    Linders, J.R.2
  • 4
    • 0025408035 scopus 로고
    • High impedance fault arcing on sandy soil in 15 kV distribution feeders: Contributions to the evaluation of the low frequency spectrum
    • Apr.
    • A. E. Emanuel, D. Cyganski, J. A. Orr, S. Shiller, and E. M. Gulachenski, "High impedance fault arcing on sandy soil in 15 kV distribution feeders: Contributions to the evaluation of the low frequency spectrum," IEEE Trans. Power Del., vol. 5, no. 2, pp. 676-686, Apr. 1990.
    • (1990) IEEE Trans. Power Del. , vol.5 , Issue.2 , pp. 676-686
    • Emanuel, A.E.1    Cyganski, D.2    Orr, J.A.3    Shiller, S.4    Gulachenski, E.M.5
  • 6
    • 0031139615 scopus 로고    scopus 로고
    • Practical high-impedance fault detection on distribution feeders
    • May/Jun.
    • C. L. Benner and B. D. Russell, "Practical high-impedance fault detection on distribution feeders," IEEE Trans. Ind. Appl., vol. 33, no. 3, pp. 635-640, May/Jun. 1997.
    • (1997) IEEE Trans. Ind. Appl. , vol.33 , Issue.3 , pp. 635-640
    • Benner, C.L.1    Russell, B.D.2
  • 8
    • 33750094485 scopus 로고    scopus 로고
    • High-impedance fault detection in distribution networks with use of wavelet-based algorithm
    • Oct.
    • M. Michalik, W. Rebizant, M. Lukowicz, S.-J. Lee, and S.-H. Kang, "High-impedance fault detection in distribution networks with use of wavelet-based algorithm," IEEE Trans. Power Del., vol. 21, no. 4, pp. 1793-1802, Oct. 2006.
    • (2006) IEEE Trans. Power Del. , vol.21 , Issue.4 , pp. 1793-1802
    • Michalik, M.1    Rebizant, W.2    Lukowicz, M.3    Lee, S.-J.4    Kang, S.-H.5
  • 10
    • 37749034316 scopus 로고    scopus 로고
    • DWT-Based detection and transient power direction- based location of high impedance faults due to leaning trees in unearthed MV networks
    • Jan.
    • N. I. Elkalashy, M. Lehtonen, H. A. Darwish, A.-M. I. Taalab, and M. A. Izzularab, "DWT-Based detection and transient power direction- based location of high impedance faults due to leaning trees in unearthed MV networks," IEEE Trans. Power Del., vol. 23, no. 1, pp. 94-101, Jan. 2008.
    • (2008) IEEE Trans. Power Del. , vol.23 , Issue.1 , pp. 94-101
    • Elkalashy, N.I.1    Lehtonen, M.2    Darwish, H.A.3    Taalab, A.-M.I.4    Izzularab, M.A.5
  • 11
    • 0033315780 scopus 로고    scopus 로고
    • Neural networks based algorithm for detecting high impedance faults on power distribution lines
    • M. Al-Dabbagh and L. Al-Dabbagh, "Neural networks based algorithm for detecting high impedance faults on power distribution lines," in Proc. Int. Joint Conf. Neural Networks, 1999, vol. 5, pp. 3386-3390.
    • (1999) Proc. Int. Joint Conf. Neural Networks , vol.5 , pp. 3386-3390
    • Al-Dabbagh, M.1    Al-Dabbagh, L.2
  • 12
    • 76249085045 scopus 로고    scopus 로고
    • Review of ground fault protection methods for grounded ungrounded and compensated distribution systems
    • J. Roberts, H. Altuve, and D. Hou, "Review of ground fault protection methods for grounded ungrounded and compensated distribution systems," in Proc. 28th Annu.Western Protective Relaying Conf., 2001, p. 10.
    • (2001) Proc. 28th Annu.Western Protective Relaying Conf. , pp. 10
    • Roberts, J.1    Altuve, H.2    Hou, D.3
  • 13
    • 11244339644 scopus 로고    scopus 로고
    • Application of the continuous wavelet transform to intermittent high impedance ground fault detection inMV networks
    • H. Belka and M. Michalik, "Application of the continuous wavelet transform to intermittent high impedance ground fault detection inMV networks," Proc. Developments in Power System Protection, vol. 2, pp. 473-476, 2008.
    • (2008) Proc. Developments in Power System Protection , vol.2 , pp. 473-476
    • Belka, H.1    Michalik, M.2
  • 14
    • 0033702053 scopus 로고    scopus 로고
    • Frequency-domain observations on definitions of reactive power
    • Jun.
    • A. M. Stankovic and H. Lev-Ari, "Frequency-domain observations on definitions of reactive power," IEEE Power Eng. Rev., vol. 20, no. 6, pp. 46-48, Jun. 2000.
    • (2000) IEEE Power Eng. Rev. , vol.20 , Issue.6 , pp. 46-48
    • Stankovic, A.M.1    Lev-Ari, H.2
  • 15
    • 0021429788 scopus 로고
    • Instantaneous reactive power compensators comprising switching devices without energy storage components
    • May
    • H. Akagi, Y. kanazawa, and A. Nabae, "Instantaneous reactive power compensators comprising switching devices without energy storage components," IEEE Trans. Ind. Appl., vol. IA-20, no. 3, pp. 625-630, May 1984.
    • (1984) IEEE Trans. Ind. Appl. , vol.IA-20 , Issue.3 , pp. 625-630
    • Akagi, H.1    Kanazawa, Y.2    Nabae, A.3
  • 16
    • 4344695727 scopus 로고    scopus 로고
    • Average and instantaneous reactive power of non-sinusoidal circuit based on Hilbert transformation
    • Y. Xue, B. Xu, and Z. Feng, "Average and instantaneous reactive power of non-sinusoidal circuit based on Hilbert transformation," Autom. Elect. Power Syst., vol. 28, pp. 35-39, 2004.
    • (2004) Autom. Elect. Power Syst. , vol.28 , pp. 35-39
    • Xue, Y.1    Xu, B.2    Feng, Z.3
  • 17
    • 67449086477 scopus 로고    scopus 로고
    • Adaptive directional relay and direction comparison protection based on instantaneous power for UHV transmission lines
    • X. Dong, S. Shi, W. Kong, Y. Li, and Z. Bo, "Adaptive directional relay and direction comparison protection based on instantaneous power for UHV transmission lines," Proc. Developments Power System Protection, pp. 275-279, 2008.
    • (2008) Proc. Developments Power System Protection , pp. 275-279
    • Dong, X.1    Shi, S.2    Kong, W.3    Li, Y.4    Bo, Z.5