Effects of needle placement inaccuracies in hepatic radiofrequency tumor ablation

Author keywords

[No Author keywords available]

Indexed keywords

ABLATED REGIONS; FINITE ELEMENT SIMULATIONS; HEPATOCELLULAR CARCINOMA; HIGH PROBABILITY; LIVER TISSUE; NEEDLE PLACEMENT; RADIO FREQUENCIES; SHORTEST DISTANCE; TUMOR ABLATION;

EID: 78650850954     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2010.5626103     Document Type: Conference Paper
Times cited : (10)

References (20)
  • 1
    • 0034853643 scopus 로고    scopus 로고
    • Image-guided radiofrequency tumor ablation: Challenges and opportunities - Part i
    • Sep.
    • S. Nahum Goldberg and D.E. Dupuy, "Image-guided radiofrequency tumor ablation: challenges and opportunities - part I," Journal of Vascular and Interventional Radiology: JVIR, vol. 12, Sep. 2001, pp. 1021-1032.
    • (2001) Journal of Vascular and Interventional Radiology: JVIR , vol.12 , pp. 1021-1032
    • Nahum Goldberg, S.1    Dupuy, D.E.2
  • 3
    • 0017208259 scopus 로고
    • Electrophysiologic principles of radiofrequency lesion making
    • L. Organ, "Electrophysiologic Principles of Radiofrequency Lesion Making," Stereotactic and Functional Neurosurgery, vol. 39, 1976, pp. 69-76.
    • (1976) Stereotactic and Functional Neurosurgery , vol.39 , pp. 69-76
    • Organ, L.1
  • 4
    • 84883841056 scopus 로고    scopus 로고
    • Numerical simulation of radio frequency ablation with state dependent material parameters in three space dimensions
    • T. Kroger, I. Altrogge, T. Preusser, P. Pereira, D. Schmidt, A. Weihusen, and H. Peitgen, "Numerical Simulation of Radio Frequency Ablation with State Dependent Material Parameters in Three Space Dimensions," MICCAI 2006, pp. 380-388.
    • MICCAI 2006 , pp. 380-388
    • Kroger, T.1    Altrogge, I.2    Preusser, T.3    Pereira, P.4    Schmidt, D.5    Weihusen, A.6    Peitgen, H.7
  • 8
    • 33644670237 scopus 로고    scopus 로고
    • Radiofrequency ablation of hepatic tumors: Simulation, planning, and contribution of virtual reality and haptics
    • Aug.
    • C. Villard, L. Soler, and A. Gangi, "Radiofrequency ablation of hepatic tumors: simulation, planning, and contribution of virtual reality and haptics," Computer Methods in Biomechanics and Biomedical Engineering, vol. 8, Aug. 2005, pp. 215-227.
    • (2005) Computer Methods in Biomechanics and Biomedical Engineering , vol.8 , pp. 215-227
    • Villard, C.1    Soler, L.2    Gangi, A.3
  • 10
    • 48349143858 scopus 로고    scopus 로고
    • Effects of variation in perfusion rates and of perfusion models in computational models of radio frequency tumor ablation
    • Aug.
    • D.J. Schutt and D. Haemmerich, "Effects of variation in perfusion rates and of perfusion models in computational models of radio frequency tumor ablation," Medical Physics, vol. 35, Aug. 2008, pp. 3462-3470.
    • (2008) Medical Physics , vol.35 , pp. 3462-3470
    • Schutt, D.J.1    Haemmerich, D.2
  • 12
    • 16844378141 scopus 로고    scopus 로고
    • Geometry and temperature distribution during radiofrequency tissue ablation: An experimental ex vivo model
    • Mar.
    • L. Lobik, R.J. Leveillee, and M.F. Hoey, "Geometry and temperature distribution during radiofrequency tissue ablation: an experimental ex vivo model," Journal of Endourology / Endourological Society, vol. 19, Mar. 2005, pp. 242-247.
    • (2005) Journal of Endourology / Endourological Society , vol.19 , pp. 242-247
    • Lobik, L.1    Leveillee, R.J.2    Hoey, M.F.3
  • 14
    • 34447508063 scopus 로고    scopus 로고
    • Expanding the bioheat equation to include tissue internal water evaporation during heating
    • Aug.
    • D. Yang, M.C. Converse, D.M. Mahvi, and J.G. Webster, "Expanding the bioheat equation to include tissue internal water evaporation during heating," IEEE Transactions on Bio-Medical Engineering, vol. 54, Aug. 2007, pp. 1382-1388.
    • (2007) IEEE Transactions on Bio-Medical Engineering , vol.54 , pp. 1382-1388
    • Yang, D.1    Converse, M.C.2    Mahvi, D.M.3    Webster, J.G.4
  • 15
    • 27744482686 scopus 로고    scopus 로고
    • Automatic control of finite element models for temperature-controlled radiofrequency ablation
    • D. Haemmerich and J. Webster, "Automatic control of finite element models for temperature-controlled radiofrequency ablation," BioMedical Engineering OnLine, vol. 4, 2005, p. 42.
    • (2005) BioMedical Engineering OnLine , vol.4 , pp. 42
    • Haemmerich, D.1    Webster, J.2
  • 16
    • 34548277425 scopus 로고    scopus 로고
    • Deal.II - A generalpurpose object-oriented finite element library
    • W. Bangerth, R. Hartmann, and G. Kanschat, "deal.II - A generalpurpose object-oriented finite element library," ACM Trans. Math. Softw., vol. 33, 2007, p. 24.
    • (2007) ACM Trans. Math. Softw. , vol.33 , pp. 24
    • Bangerth, W.1    Hartmann, R.2    Kanschat, G.3
  • 17
    • 79959374411 scopus 로고    scopus 로고
    • Ver. 2.3, http://www.truegrid.com/pub/TGMAN230.2.pdf
    • TrueGrid, "TrueGrid® User's Manual," Ver. 2.3, 2006. http://www.truegrid.com/pub/TGMAN230.1.pdf http://www.truegrid.com/pub/TGMAN230. 2.pdf
    • (2006) TrueGrid® User's Manual
  • 18
    • 0035115565 scopus 로고    scopus 로고
    • Hepatic perfusion parameters in chronic liver disease: Dynamic CT measurements correlated with disease severity
    • Mar.
    • B.E. Van Beers, I. Leconte, R. Materne, A.M. Smith, J. Jamart, and Y. Horsmans, "Hepatic Perfusion Parameters in Chronic Liver Disease: Dynamic CT Measurements Correlated with Disease Severity," Am. J. Roentgenol., vol. 176, Mar. 2001, pp. 667-673.
    • (2001) Am. J. Roentgenol. , vol.176 , pp. 667-673
    • Van Beers, B.E.1    Leconte, I.2    Materne, R.3    Smith, A.M.4    Jamart, J.5    Horsmans, Y.6
  • 19
    • 0032014184 scopus 로고    scopus 로고
    • In vivo assessment of neovascularization of liver metastases using perfusion CT
    • Mar.
    • K. Miles, D. Leggett, B. Kelley, M. Hayball, R. Sinnatamby, and I. Bunce, "In vivo assessment of neovascularization of liver metastases using perfusion CT," Br J Radiol, vol. 71, Mar. 1998, pp. 276-281.
    • (1998) Br J Radiol , vol.71 , pp. 276-281
    • Miles, K.1    Leggett, D.2    Kelley, B.3    Hayball, M.4    Sinnatamby, R.5    Bunce, I.6
  • 20
    • 0942287356 scopus 로고    scopus 로고
    • Quantitative perfusion map of malignant liver tumors, created from dynamic computed tomography data
    • Feb.
    • Y. Tsushima, S. Funabasama, J. Aoki, S. Sanada, and K. Endo, "Quantitative perfusion map of malignant liver tumors, created from dynamic computed tomography data," Academic Radiology, vol. 11, Feb. 2004, pp. 215-223.
    • (2004) Academic Radiology , vol.11 , pp. 215-223
    • Tsushima, Y.1    Funabasama, S.2    Aoki, J.3    Sanada, S.4    Endo, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.