메뉴 건너뛰기




Volumn , Issue , 2010, Pages 871-874

High-resolution cardiac MRI using partially separable functions and weighted spatial smoothness regularization

Author keywords

[No Author keywords available]

Indexed keywords

ANATOMICAL CONSTRAINT; CARDIAC MRI; EXPERIMENTAL DATA; HIGH RESOLUTION; IMAGING SPEED; IN-PLANE; PARTIALLY SEPARABLE FUNCTIONS; RAT HEART; SPACE DATA; SPATIAL RESOLUTION; SPATIAL SMOOTHNESS; SPATIO-TEMPORAL RESOLUTION; TEMPORAL RESOLUTION; TIME AXIS;

EID: 78650844976     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2010.5627889     Document Type: Conference Paper
Times cited : (18)

References (16)
  • 2
    • 33750372663 scopus 로고    scopus 로고
    • Cardiac MR imaging: State of the technology
    • November
    • J. P. Finn, K. Nael, V. Deshpande, O. Ratib, and G. Laub, "Cardiac MR imaging: State of the technology," Radiology, vol. 241, no. 2, pp. 338-354, November 2006.
    • (2006) Radiology , vol.241 , Issue.2 , pp. 338-354
    • Finn, J.P.1    Nael, K.2    Deshpande, V.3    Ratib, O.4    Laub, G.5
  • 3
    • 0032751897 scopus 로고    scopus 로고
    • Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
    • B. Madore, G. Glover, and N. J. Pelc, "Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI," Magn Reson Med, vol. 42, pp. 813-828, 1999.
    • (1999) Magn Reson Med , vol.42 , pp. 813-828
    • Madore, B.1    Glover, G.2    Pelc, N.J.3
  • 4
    • 49749091687 scopus 로고    scopus 로고
    • Patient-adapted reconstruction and acquisition dynamic imaging method (PARADIGM) for MRI
    • N. Aggarwal and Y. Bresler, "Patient-adapted reconstruction and acquisition dynamic imaging method (PARADIGM) for MRI," Inverse Probl, vol. 24, 2008.
    • (2008) Inverse Probl , vol.24
    • Aggarwal, N.1    Bresler, Y.2
  • 5
    • 0242385483 scopus 로고    scopus 로고
    • K-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • J. Tsao, P. Boesiger, and K. P. Pruessmann, "k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations," Magn Reson Med, vol. 50, pp. 1031-1042, 2003.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 6
    • 60349105482 scopus 로고    scopus 로고
    • K-t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
    • H. Jung, K. Sung, K. S. Nayak, E. Y. Kim, and J. C. Ye, "k-t FOCUSS: a general compressed sensing framework for high resolution dynamic MRI," Magn Reson Med, vol. 61, pp. 103-116, 2009.
    • (2009) Magn Reson Med , vol.61 , pp. 103-116
    • Jung, H.1    Sung, K.2    Nayak, K.S.3    Kim, E.Y.4    Ye, J.C.5
  • 7
    • 36348994822 scopus 로고    scopus 로고
    • Spatiotemporal imaging with partially separable functions
    • Z.-P. Liang, "Spatiotemporal imaging with partially separable functions," in Proc IEEE Int Symp Biomed Imaging, 2007, pp. 988-991.
    • (2007) Proc IEEE Int Symp Biomed Imaging , pp. 988-991
    • Liang, Z.-P.1
  • 11
    • 78650803541 scopus 로고    scopus 로고
    • PSF model-based reconstruction with sparsity constraint: Algorithm and application to real-time cardiac MRI
    • to be published
    • B. Zhao, J. P. Haldar, and Z.-P. Liang, "PSF model-based reconstruction with sparsity constraint: Algorithm and application to real-time cardiac MRI," in Conf Proc IEEE Eng Med Biol Soc, 2010, to be published.
    • (2010) Conf Proc IEEE Eng Med Biol Soc
    • Zhao, B.1    Haldar, J.P.2    Liang, Z.-P.3
  • 12
    • 0027468047 scopus 로고
    • K-space description for MR imaging of dynamic objects
    • Q.-S. Xiang and R. M. Henkelman, "K-space description for MR imaging of dynamic objects," Magn Reson Med, vol. 29, pp. 422- 428, 1993.
    • (1993) Magn Reson Med , vol.29 , pp. 422-428
    • Xiang, Q.-S.1    Henkelman, R.M.2
  • 13
    • 41849149681 scopus 로고    scopus 로고
    • Anatomically constrained reconstruction from noisy data
    • J. P. Haldar, D. Hernando, S.-K. Song, and Z.-P. Liang, "Anatomically constrained reconstruction from noisy data," Magn Reson Med, vol. 59, pp. 810-818, 2008.
    • (2008) Magn Reson Med , vol.59 , pp. 810-818
    • Haldar, J.P.1    Hernando, D.2    Song, S.-K.3    Liang, Z.-P.4
  • 14
    • 63449102799 scopus 로고    scopus 로고
    • Undersampled radial MR acquisition and highly constrained back projection (HYPR) reconstruction: Potential medical imaging applications in the post-Nyquist era
    • C. A. Mistretta, "Undersampled radial MR acquisition and highly constrained back projection (HYPR) reconstruction: Potential medical imaging applications in the post-Nyquist era," J Magn Reson Imaging, vol. 29, no. 3, pp. 501-516, 2009.
    • (2009) J Magn Reson Imaging , vol.29 , Issue.3 , pp. 501-516
    • Mistretta, C.A.1
  • 16
    • 32444439642 scopus 로고    scopus 로고
    • In situ labeling of immune cells with iron oxide particles: An approach to detect organ rejection by cellular MRI
    • Feb
    • Y.-J. L. Wu, Q. Ye, L. M. Foley, T. K. Hitchens, K. Sato, J. B. Williams, and C. Ho, "In situ labeling of immune cells with iron oxide particles: An approach to detect organ rejection by cellular MRI," Proc Natl Acad Sci U S A, vol. 103, no. 6, pp. 1852-1857, Feb 2006.
    • (2006) Proc Natl Acad Sci U S A , vol.103 , Issue.6 , pp. 1852-1857
    • Wu, Y.-J.L.1    Ye, Q.2    Foley, L.M.3    Hitchens, T.K.4    Sato, K.5    Williams, J.B.6    Ho, C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.