메뉴 건너뛰기




Volumn , Issue , 2010, Pages 6437-6440

A high-power versatile wireless power transfer for biomedical implants

Author keywords

[No Author keywords available]

Indexed keywords

AIR-CORE; BIOMEDICAL ACTUATORS; BIOMEDICAL IMPLANTS; ELECTRICAL PROPERTY; GEOMETRICAL ARRANGEMENTS; HIGH-POWER; IMPEDANCE MATCHING NETWORK; INDUCTIVE COILS; MODERN MEDICINE; NON-INVASIVE; OPERATING FREQUENCY; POWER SOURCES; RADIO FREQUENCIES; TECHNICAL CONSTRAINTS; WIRELESS POWER TRANSFER;

EID: 78650838170     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2010.5627329     Document Type: Conference Paper
Times cited : (14)

References (13)
  • 1
    • 0017559930 scopus 로고
    • Design of radio-frequency powered coils for design of radio-frequency powered coils for implant instruments
    • Nov.
    • W. H. Ko, S. P. Liang, and C. D. F. Fung, "Design of radio-frequency powered coils for design of radio-frequency powered coils for implant instruments," Med & Bio. Eng. & Comput., pp. 634-640, Nov. 1977.
    • (1977) Med & Bio. Eng. & Comput. , pp. 634-640
    • Ko, W.H.1    Liang, S.P.2    Fung, C.D.F.3
  • 3
    • 0023324937 scopus 로고
    • Radio-Frequency coils in implantable devices: Misalignment analysis and design procedure
    • April
    • M. Soma, D. C. Galbraith, and R. L. White, "Radio-Frequency coils in implantable devices: Misalignment analysis and design procedure," IEEE Trans. Biomed. Eng., pp. 276-282, April 1987.
    • (1987) IEEE Trans. Biomed. Eng. , pp. 276-282
    • Soma, M.1    Galbraith, D.C.2    White, R.L.3
  • 4
    • 34548827377 scopus 로고    scopus 로고
    • Designing efficient inductive power links for implantable devices
    • May.
    • R. Harrison, "Designing efficient inductive power links for implantable devices," in IEEE ISCAS 2007, May. 2007, pp. 2080-2083.
    • (2007) IEEE ISCAS 2007 , pp. 2080-2083
    • Harrison, R.1
  • 5
    • 34247889987 scopus 로고    scopus 로고
    • Feedback analysis and design of RF power links for low-power bionic systems
    • Mar.
    • M. Baker and R. Sarpeshkar, "Feedback analysis and design of RF power links for low-power bionic systems," IEEE Trans. Biomed. Circuits Syst., pp. 28-38, Mar. 2007.
    • (2007) IEEE Trans. Biomed. Circuits Syst. , pp. 28-38
    • Baker, M.1    Sarpeshkar, R.2
  • 6
    • 39549107342 scopus 로고    scopus 로고
    • Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission
    • Sept.
    • U. M. Jow and M. Ghovanloo, "Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission," IEEE Trans. Biomed. Circuits Syst., pp. 193-202, Sept. 2007.
    • (2007) IEEE Trans. Biomed. Circuits Syst. , pp. 193-202
    • Jow, U.M.1    Ghovanloo, M.2
  • 8
    • 78650843064 scopus 로고    scopus 로고
    • [Online] Available: http://www.pediatricdeviceconsortium.org/devices/ roboimplant
    • http://www.pediatricdeviceconsortium.org/devices/roboimplant. [Online]. Available: http://www.pediatricdeviceconsortium.org/devices/roboimplant
  • 10
    • 27644482714 scopus 로고    scopus 로고
    • Distant energy transfer for artificial human implants
    • Nov.
    • M. Theodoridis and S. Mollov, "Distant energy transfer for artificial human implants," IEEE Trans. Biomed. Eng., pp. 1931-1938, Nov. 2005.
    • (2005) IEEE Trans. Biomed. Eng. , pp. 1931-1938
    • Theodoridis, M.1    Mollov, S.2
  • 11
    • 77951018841 scopus 로고    scopus 로고
    • A mm-sized implantable wireless power receiver
    • Minneapolis, MN, Sept.
    • A. Poon, "A mm-sized implantable wireless power receiver," in Proc. IEEE EMBS Annual International Conf., Minneapolis, MN, Sept. 2009, pp. 3217 - 3220.
    • (2009) Proc. IEEE EMBS Annual International Conf. , pp. 3217-3220
    • Poon, A.1
  • 13
    • 33646754901 scopus 로고    scopus 로고
    • The dependence of electromagnetic far-field absorption on body tissue composition in the frequency range from 300 MHz to 6 GHz
    • Mar
    • A. Christ, A. Klingenbock, T. Samaras, C. Goiceanu, and N. Kuster, "The dependence of electromagnetic far-field absorption on body tissue composition in the frequency range from 300 MHz to 6 GHz," IEEE MTT, vol. 54, no. 5, pp. 2188-2195, Mar 2006.
    • (2006) IEEE MTT , vol.54 , Issue.5 , pp. 2188-2195
    • Christ, A.1    Klingenbock, A.2    Samaras, T.3    Goiceanu, C.4    Kuster, N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.