메뉴 건너뛰기




Volumn , Issue , 2010, Pages 2467-2472

Electrical circuit models of the human respiratory system reflect small airway impairment measured by Impulse Oscillation (IOS)

Author keywords

[No Author keywords available]

Indexed keywords

CHRONIC OBSTRUCTIVE LUNG DISEASE; CYSTIC FIBROSIS; ELECTRICAL CIRCUIT MODELS; FREQUENCY DEPENDENCE; HUMAN RESPIRATORY SYSTEM; IMPULSE OSCILLOMETRY; INPUT IMPEDANCE; LOW FREQUENCY; MEDICAL STUDIES; RESPIRATORY IMPEDANCE; SENSITIVE INDEX; SHUNT CAPACITANCE; SMALL AIRWAYS; UPPER AIRWAY;

EID: 78650834020     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2010.5626611     Document Type: Conference Paper
Times cited : (15)

References (29)
  • 1
    • 1642570300 scopus 로고    scopus 로고
    • Is forced expiratory volume in one second the best measure of severity in childhood asthma?
    • J. D. Spahn, R. Cherniack, K. Paull, E. W. Gelfand. "Is forced expiratory volume in one second the best measure of severity in childhood asthma?" Am J Respir Crit Care Med 2004 169: 784-6.
    • (2004) Am J Respir Crit Care Med , vol.169 , pp. 784-786
    • Spahn, J.D.1    Cherniack, R.2    Paull, K.3    Gelfand, E.W.4
  • 3
    • 78650838382 scopus 로고    scopus 로고
    • Relationship between small airway function and health status, dyspnea and disease control in asthma
    • Sep 22. [Epub ahead of print]
    • T. Takeda, T. Oga, A. Niimi, H. Matsumoto, I. Ito, M. Yamaguchi et al. "Relationship between Small Airway Function and Health Status, Dyspnea and Disease Control in Asthma." Respiration. 2009 Sep 22. [Epub ahead of print]
    • (2009) Respiration
    • Takeda, T.1    Oga, T.2    Niimi, A.3    Matsumoto, H.4    Ito, I.5    Yamaguchi, M.6
  • 4
    • 63449107671 scopus 로고    scopus 로고
    • Impulse oscillometry versus spirometry in a long-term study of controller therapy for pediatric asthma
    • G. Larsen, W. Morgan, G. Heldt. "Impulse oscillometry versus spirometry in a long-term study of controller therapy for pediatric asthma." J Allergy Clin Immunol 2009; 123:861-7.
    • (2009) J Allergy Clin Immunol , vol.123 , pp. 861-867
    • Larsen, G.1    Morgan, W.2    Heldt, G.3
  • 5
    • 67349245921 scopus 로고    scopus 로고
    • Effect of inhaled corticosteroids on small airways in asthma: Investigation using impulse oscillometry
    • M. Yamaguchi, A. Niimi, T. Ueda, M. Takemura, H. Matsuoka, M. Jinnai et al. "Effect of inhaled corticosteroids on small airways in asthma: investigation using impulse oscillometry." Pulm Pharmacol Ther. 2009;22:326-32.
    • (2009) Pulm Pharmacol Ther. , vol.22 , pp. 326-332
    • Yamaguchi, M.1    Niimi, A.2    Ueda, T.3    Takemura, M.4    Matsuoka, H.5    Jinnai, M.6
  • 6
    • 77949663450 scopus 로고    scopus 로고
    • Comparison of effectiveness in ciclesonide and fluticasone propionate on small airway function in mild asthma
    • M. Hoshino. "Comparison of Effectiveness in Ciclesonide and Fluticasone Propionate on Small Airway Function in Mild Asthma." Allergol Int. 2010;59:59-66
    • (2010) Allergol Int. , vol.59 , pp. 59-66
    • Hoshino, M.1
  • 7
    • 0022337588 scopus 로고
    • Respiratory impedance measured with a head generador to minimize upper airway shunt
    • R. Peslin, C. Duvivier, J. Didelon, C. Gallina. "Respiratory impedance measured with a head generador to minimize upper airway shunt." J Appl Physiol 1985; 59:1790-5
    • (1985) J Appl Physiol , vol.59 , pp. 1790-1795
    • Peslin, R.1    Duvivier, C.2    Didelon, J.3    Gallina, C.4
  • 8
    • 0024413703 scopus 로고
    • Effect of upper airway shunt and series properties on respiratory impedance measurements
    • M. Cauberghs, K. P. Van de Woestijne. "Effect of upper airway shunt and series properties on respiratory impedance measurements." J Appl Physiol. 1989;66(5):2274-9.
    • (1989) J Appl Physiol. , vol.66 , Issue.5 , pp. 2274-2279
    • Cauberghs, M.1    Van De Woestijne, K.P.2
  • 9
    • 0027077714 scopus 로고
    • Changes of respiratory input impedance during breathing in humans
    • M. Cauberghs, K. P. Van de Woestijne. "Changes of respiratory input impedance during breathing in humans." J Appl Physiol. 1992;73(6):2355-62.
    • (1992) J Appl Physiol. , vol.73 , Issue.6 , pp. 2355-2362
    • Cauberghs, M.1    Van De Woestijne, K.P.2
  • 10
    • 0014514840 scopus 로고
    • Contribution of compliance of airways to frequency dependent behavior of lungs
    • J. Mead. "Contribution of compliance of airways to frequency dependent behavior of lungs." J. Appl. Physiol. 1969, 26, 670-3.
    • (1969) J. Appl. Physiol. , vol.26 , pp. 670-673
    • Mead, J.1
  • 11
    • 34047093821 scopus 로고    scopus 로고
    • Can asthma in children be detected by the estimated parameter values of the augmented ric model?
    • 28th Annual International Conference, New York City, USA, Aug 30-Sep 3
    • A. Rajagiri, B. Diong, M. Goldman, H. Nazeran. "Can Asthma in Children be Detected by the Estimated Parameter Values of the Augmented RIC Model?", Proceedings of the IEEE-Engineering in Medicine and Biology Society (EMBS), 28th Annual International Conference, pp. 5595-5598, New York City, USA, Aug 30-Sep 3, 2006
    • (2006) Proceedings of the IEEE-Engineering in Medicine and Biology Society (EMBS) , pp. 5595-5598
    • Rajagiri, A.1    Diong, B.2    Goldman, M.3    Nazeran, H.4
  • 16
    • 8744225346 scopus 로고    scopus 로고
    • Respiratory symptoms and physiologic assessment of ironworkers at the world trade center disaster site
    • G. Skloot, M. Goldman, D. Fischler, C. Goldman, C. Schechter, S. Levin, et al. "Respiratory Symptoms and Physiologic Assessment of Ironworkers at the World Trade Center Disaster Site." Chest, 2004; 125:1248-1255
    • (2004) Chest , vol.125 , pp. 1248-1255
    • Skloot, G.1    Goldman, M.2    Fischler, D.3    Goldman, C.4    Schechter, C.5    Levin, S.6
  • 17
    • 78650818760 scopus 로고    scopus 로고
    • Reproducibility of impulse oscillometry (IOS) within and between tests
    • abstract
    • E. Toon, D. Bilton, M. D. Goldman, K. E. Oates. "Reproducibility of Impulse Oscillometry (IOS) within and between tests." Proc. Am Thoracic Soc. 2005; 2:A34 (abstract)
    • (2005) Proc. Am Thoracic Soc. , vol.2
    • Toon, E.1    Bilton, D.2    Goldman, M.D.3    Oates, K.E.4
  • 18
    • 0034775686 scopus 로고    scopus 로고
    • Clinical application of forced oscillation
    • M. Goldman. "Clinical Application of Forced Oscillation." Pul Pharm Ther, 2001; 14: 341-50.
    • (2001) Pul Pharm Ther , vol.14 , pp. 341-350
    • Goldman, M.1
  • 19
    • 23744448863 scopus 로고    scopus 로고
    • Clinical applications of forced oscillation to assess perhiperal airway function
    • M. Goldman, C. Saadeh, D. Ross. "Clinical Applications of Forced Oscillation to Assess Perhiperal Airway Function." Res Physiol Neuro 2005; 148:179-94
    • (2005) Res Physiol Neuro , vol.148 , pp. 179-194
    • Goldman, M.1    Saadeh, C.2    Ross, D.3
  • 20
    • 23744503908 scopus 로고    scopus 로고
    • Forced oscillation technique and impulse oscillometry
    • H. Smith, P. Reinhold, M. Goldman. "Forced oscillation technique and impulse oscillometry." Eur. Respir. Mon. 2005; 31:72-105
    • (2005) Eur. Respir. Mon. , vol.31 , pp. 72-105
    • Smith, H.1    Reinhold, P.2    Goldman, M.3
  • 21
    • 0014062847 scopus 로고
    • Resistance of central and peripheral airways measured by a retrograde catheter
    • P. Macklem, J. Mead. "Resistance of central and peripheral airways measured by a retrograde catheter." J. Appl. Physiol. 1967;22:395-401
    • (1967) J. Appl. Physiol. , vol.22 , pp. 395-401
    • MacKlem, P.1    Mead, J.2
  • 22
    • 78650806823 scopus 로고    scopus 로고
    • Circuit analysis justifies a rduced mead's model of the human respiratory impedance for impulse oscillometry data
    • Buenos Aires, Argentina, August 31- September 4
    • C. Ramos, H. Nazeran, M.D. Goldman, B. Diong. "Circuit Analysis Justifies a Rduced Mead's Model of the Human Respiratory Impedance for Impulse Oscillometry Data." Proceedings of the IEEE EMBS 32nd Annual International Conference, Buenos Aires, Argentina, August 31- September 4, 2010.
    • (2010) Proceedings of the IEEE EMBS 32nd Annual International Conference
    • Ramos, C.1    Nazeran, H.2    Goldman, M.D.3    Diong, B.4
  • 23
    • 0034881120 scopus 로고    scopus 로고
    • Forced oscillation technique to evaluate tracheostenosis in patients with neurologic injury
    • T. Horan, S. Mateus, P. Beraldo, L. Araújo, J. Urschel, E. Urmenyi, F. Santiago. Forced oscillation technique to evaluate tracheostenosis in patients with neurologic injury. Chest. 2001;120:69-73.
    • (2001) Chest , vol.120 , pp. 69-73
    • Horan, T.1    Mateus, S.2    Beraldo, P.3    Araújo, L.4    Urschel, J.5    Urmenyi, E.6    Santiago, F.7
  • 24
    • 0028358809 scopus 로고
    • Measurement of respiratory impedance by forced oscillation: Comparison of the standard and head generator methods
    • Y. Iwatsubo, H. Lorino, C. Hubert, C. Duvivier, R. Peslin, Q. T. Pham et al. "Measurement of respiratory impedance by forced oscillation: comparison of the standard and head generator methods." Eur Respir J. 1994;7(5):901-6.
    • (1994) Eur Respir J. , vol.7 , Issue.5 , pp. 901-906
    • Iwatsubo, Y.1    Lorino, H.2    Hubert, C.3    Duvivier, C.4    Peslin, R.5    Pham, Q.T.6
  • 25
    • 0018398207 scopus 로고
    • Human pulmonary resistance: Effect of frequency and gas physical properties
    • P. V. Bhansali, C. G. Irvin, J. A. Dempsey, R. Bush, J. G. Webster. "Human pulmonary resistance: effect of frequency and gas physical properties." J Appl Physiol. 1979;47(1):161-8.
    • (1979) J Appl Physiol. , vol.47 , Issue.1 , pp. 161-168
    • Bhansali, P.V.1    Irvin, C.G.2    Dempsey, J.A.3    Bush, R.4    Webster, J.G.5
  • 27
    • 0015834638 scopus 로고
    • Interrelation between alterations in pulmonary mechanics and hemodynamics in acute myocardial infarction
    • B. Interiano, R. W. Hyde, M. Hodges, P. N. Yu "Interrelation between alterations in pulmonary mechanics and hemodynamics in acute myocardial infarction." J Clin Invest. 1973; 52:1994-2006
    • (1973) J Clin Invest. , vol.52 , pp. 1994-2006
    • Interiano, B.1    Hyde, R.W.2    Hodges, M.3    Yu, P.N.4
  • 28
    • 0031608180 scopus 로고    scopus 로고
    • Measurement of respiratory impedance in healthy calves using the Impulse Oscillation technique - Physiological and Methodological aspects
    • P. Reinhold, H.-J. Smith, A. Langenberg, P. Lekeux. "Measurement of respiratory impedance in healthy calves using the Impulse Oscillation technique - Physiological and Methodological aspects." Vet J 1998; 155: 27-38
    • (1998) Vet J , vol.155 , pp. 27-38
    • Reinhold, P.1    Smith, H.-J.2    Langenberg, A.3    Lekeux, P.4
  • 29
    • 0016615988 scopus 로고
    • Resistance of intrathoracic airways of healthy subjects during periodic flow
    • K. E. Finucane, S. V. Dawson, P. D. Phelan, J. Mead. "Resistance of intrathoracic airways of healthy subjects during periodic flow." J Appl Physiol 1975; 38:517-30
    • (1975) J Appl Physiol , vol.38 , pp. 517-530
    • Finucane, K.E.1    Dawson, S.V.2    Phelan, P.D.3    Mead, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.