메뉴 건너뛰기




Volumn , Issue , 2010, Pages 2053-2056

Reduced spatial focality of electrical field in tDCS with ring electrodes due to tissue anisotropy

Author keywords

[No Author keywords available]

Indexed keywords

ANISOTROPIC CONDUCTIVITY; EFFECTIVE STIMULATION; ELECTRICAL FIELD; FINITE ELEMENTS; HEAD MODEL; HIGH RESOLUTION; INDUCED ELECTRICAL FIELD; RING ELECTRODES; WHITE MATTER;

EID: 78650801790     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2010.5626502     Document Type: Conference Paper
Times cited : (27)

References (18)
  • 1
    • 0034666046 scopus 로고    scopus 로고
    • Excitability changes induced in the human motor cortex by transcranial direct current stimulation
    • M. A. Nitsche and W. Paulus, "Excitability changes induced in the human motor cortex by transcranial direct current stimulation," J. physiol., vol. 527.3, pp. 633-639, 2000.
    • (2000) J. Physiol. , vol.527 , Issue.3 , pp. 633-639
    • Nitsche, M.A.1    Paulus, W.2
  • 2
    • 68549125229 scopus 로고    scopus 로고
    • A Treatment of depression with transcranial direct current stimulation (tDCS): A Review
    • M. A. Nitsche, S. B Paulus, F. Fregni, and Pascual-Leone "A Treatment of depression with transcranial direct current stimulation (tDCS): A Review," Exp. Neurology., vol. 219, pp. 14-19, 2009.
    • (2009) Exp. Neurology. , vol.219 , pp. 14-19
    • Nitsche, M.A.1    Paulus, S.B.2    Fregni, F.3    Pascual-Leone4
  • 3
    • 33745968282 scopus 로고    scopus 로고
    • Non-invasive brain simulation: A new strategy to improve neurorehabilitation after stroke?
    • F. C. Hummel and L. G Cohen, "Non-invasive brain simulation: a new strategy to improve neurorehabilitation after stroke?," Lancet Neurol., vol. 5, pp.708-712, 2006.
    • (2006) Lancet Neurol. , vol.5 , pp. 708-712
    • Hummel, F.C.1    Cohen, L.G.2
  • 4
    • 33947714465 scopus 로고    scopus 로고
    • Transcranial direct current stimulation: A computer-based human model study
    • T. Wagner, F. Fregni, S. Fecteat, A. Grodzinsky, and M. Zahn, "Transcranial direct current stimulation: a computer-based human model study," NeuroImage, vol. 35, pp. 1113-24, 2007
    • (2007) NeuroImage , vol.35 , pp. 1113-24
    • Wagner, T.1    Fregni, F.2    Fecteat, S.3    Grodzinsky, A.4    Zahn, M.5
  • 6
    • 33645276285 scopus 로고    scopus 로고
    • A controlled clinical trial of cathodal DC polarization in patients with refractory epilepsy
    • F. Fregin, S. Thome-Souza, M. A. Nitsche, S. D. Freedman, K. D. Valente, and A. Pascual-Leone, "A controlled clinical trial of cathodal DC polarization in patients with refractory epilepsy," Epilepsia, vol. 75, pp. 335-342, 2006.
    • (2006) Epilepsia , vol.75 , pp. 335-342
    • Fregin, F.1    Thome-Souza, S.2    Nitsche, M.A.3    Freedman, S.D.4    Valente, K.D.5    Pascual-Leone, A.6
  • 7
    • 47349090900 scopus 로고    scopus 로고
    • Trasncranial current stimulation focality using disc and ring electrode configurations: FEM analysis
    • A. Datta, M. Elwassif, F. Battaglia, and M. Bikson, "Trasncranial current stimulation focality using disc and ring electrode configurations: FEM analysis," J. Neural Eng, vol. 5, pp. 163-74, 2008.
    • (2008) J. Neural Eng , vol.5 , pp. 163-74
    • Datta, A.1    Elwassif, M.2    Battaglia, F.3    Bikson, M.4
  • 8
    • 68149086370 scopus 로고    scopus 로고
    • Gyri-precise head model of transcranial direct current stimulation: Improved spatial focality using a ring electrode versus conventional rectangular pad
    • A. Datta, V. Bansal, J. Diaz, J. Patel, D. Reato, and M. Bikson, "Gyri-precise head model of transcranial direct current stimulation: Improved spatial focality using a ring electrode versus conventional rectangular pad," Brain Stimul., vol. 2, pp. 201-207, 2009.
    • (2009) Brain Stimul. , vol.2 , pp. 201-207
    • Datta, A.1    Bansal, V.2    Diaz, J.3    Patel, J.4    Reato, D.5    Bikson, M.6
  • 9
    • 78650820741 scopus 로고    scopus 로고
    • Comparing different configurations using the 10-10 international system in tDCS: A finite element model analysis
    • Minnesota, USA, September 2-6
    • F. Paula, L. Alberto, and P. C. Miranda, "Comparing different configurations using the 10-10 international system in tDCS: a finite element model analysis," IEEE EMBS, Minnesota, USA, September 2-6, 2009.
    • (2009) IEEE EMBS
    • Paula, F.1    Alberto, L.2    Miranda, P.C.3
  • 10
    • 33744904694 scopus 로고    scopus 로고
    • Predicted current densities in the brain during transcranial electrical stimulation
    • R. N. Holderfer, R. Sadlier, and M. J. Russell, "Predicted current densities in the brain during transcranial electrical stimulation," Clin. Neurophysiol, vol. 117, pp. 1388-1397, 2006.
    • (2006) Clin. Neurophysiol , vol.117 , pp. 1388-1397
    • Holderfer, R.N.1    Sadlier, R.2    Russell, M.J.3
  • 11
    • 61849108781 scopus 로고    scopus 로고
    • 3-D diffusion tensor MRI anisotropy content-adaptive finite element model generation for bioelectromagnetic imaging
    • Vancouver, Canada, August 20-24
    • W. H. Lee, T. - S. Kim, A. T. Kim, and S. Y. Lee, "3-D diffusion tensor MRI anisotropy content-adaptive finite element model generation for bioelectromagnetic imaging," IEEE EMBS, Vancouver, Canada, August 20-24, 2008.
    • (2008) IEEE EMBS
    • Lee, W.H.1    Kim, T.-S.2    Kim, A.T.3    Lee, S.Y.4
  • 12
    • 0037291599 scopus 로고    scopus 로고
    • Influence of conductivity tensors on the scalp electrical potential: Study with 2-D finite element models
    • S. Kim, T. - S. Kim, Y. Zhou, and M. Singh, "Influence of conductivity tensors on the scalp electrical potential: Study with 2-D finite element models," IEEE Trans. Nucl. Sci., vol. 50, pp. 133-138, 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 133-138
    • Kim, S.1    Kim, T.-S.2    Zhou, Y.3    Singh, M.4
  • 13
    • 33645751551 scopus 로고    scopus 로고
    • Influence of tissue conductivity anisotropy on EEG/MEG field and return current computation in a realistic head model: A simulation and visualization study using high-resolution finite element modeling
    • C. H. Wolters, A. Anwander, X. Tricoche, D. Weinstein, M. A. Koch, and R. S. Macleod, "Influence of tissue conductivity anisotropy on EEG/MEG field and return current computation in a realistic head model: A simulation and visualization study using high-resolution finite element modeling," NeuroImage, vol. 30, pp. 813-826, 2006.
    • (2006) NeuroImage , vol.30 , pp. 813-826
    • Wolters, C.H.1    Anwander, A.2    Tricoche, X.3    Weinstein, D.4    Koch, M.A.5    MacLeod, R.S.6
  • 14
    • 0028154030 scopus 로고
    • MR diffusion tensor spectroscopy and imaging
    • P. J. Basser, J. Mattiello, and D. LeBihan, "MR diffusion tensor spectroscopy and imaging," Biophys. J., vol. 66, pp. 259-267, 1994.
    • (1994) Biophys. J. , vol.66 , pp. 259-267
    • Basser, P.J.1    Mattiello, J.2    Lebihan, D.3
  • 15
    • 0032779354 scopus 로고    scopus 로고
    • Conductivity mapping of biological tissue using diffusion MRI
    • D. Tuch, V. Wedeen, A. Dale, J. George, and J. Belliveau, "Conductivity mapping of biological tissue using diffusion MRI," Ann. N.Y. Acad. Sci., vol. 888, pp. 314-316, 1999.
    • (1999) Ann. N.Y. Acad. Sci. , vol.888 , pp. 314-316
    • Tuch, D.1    Wedeen, V.2    Dale, A.3    George, J.4    Belliveau, J.5
  • 16
    • 77950975207 scopus 로고    scopus 로고
    • Realistic Simulation of Transcranial Direct Current Stimulation via 3-D High-resolution Finite Element Analysis: Effect of Tissue Anisotropy
    • Minnesota, USA, September 2-6
    • H. S. Suh, S. H. Kim, W. H. Lee, and T.-S. Kim, "Realistic Simulation of Transcranial Direct Current Stimulation via 3-D High-resolution Finite Element Analysis: Effect of Tissue Anisotropy," IEEE EMBS, Minnesota, USA, September 2-6, 2009.
    • (2009) IEEE EMBS
    • Suh, H.S.1    Kim, S.H.2    Lee, W.H.3    Kim, T.-S.4
  • 17
    • 1242283941 scopus 로고    scopus 로고
    • EEGLAB: An open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
    • A. Delorme and S. Makeig, "EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis," J. Neuro. Method, vol. 134, pp. 9-21, 2004
    • (2004) J. Neuro. Method , vol.134 , pp. 9-21
    • Delorme, A.1    Makeig, S.2
  • 18
    • 78650837833 scopus 로고    scopus 로고
    • Available
    • ANSYS. Available: http://www.ansys.com/