메뉴 건너뛰기




Volumn 268, Issue 1-3, 2011, Pages 204-207

Removal of turbidity and suspended solids by electro-coagulation to improve feed water quality of reverse osmosis plant

Author keywords

Electro coagulation; Fouling; Reverse osmosis; Turbidity; Water treatment

Indexed keywords

CAPITAL COSTS; EFFICIENT METHOD; ELECTRO-COAGULATION; ENVIRONMENTAL RESTRICTION; FEED WATER; IRON ELECTRODES; REMOVAL EFFICIENCIES; RESIDENCE TIME; REVERSE OSMOSIS PLANTS; SILT DENSITY INDEX; SUSPENDED SOLIDS; TOTAL SUSPENDED SOLIDS; TREATMENT TECHNOLOGIES; WATER FLOWS; WATER SAMPLES; WELL WATER;

EID: 78650794842     PISSN: 00119164     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.desal.2010.10.027     Document Type: Article
Times cited : (57)

References (18)
  • 2
    • 79951727195 scopus 로고    scopus 로고
    • Electrolytic treatment of turbid water in package plant
    • Paul a.b. electrolytic treatment of turbid water in package plant. 22nd WEDC Conference , New Delhi India 1996, 35-47.
    • (1996) 22nd WEDC Conference , New Delhi India , pp. 35-47
    • Paul, A.1
  • 3
    • 0242418220 scopus 로고    scopus 로고
    • Comparative electro coagulation inactivation of bacteria and bacteriophage
    • Dress k., abbaszadegan m., maier r. Comparative electro coagulation inactivation of bacteria and bacteriophage. wat res uk 2003, 37:2291-2300.
    • (2003) wat res uk , vol.37 , pp. 2291-2300
    • Dress, K.1    abbaszadegan, M.2    maier, R.3
  • 4
    • 0032055427 scopus 로고    scopus 로고
    • Saline wastewater treatment by electrochemical method
    • Lin s.h., shyu c.t., sun m.c. Saline wastewater treatment by electrochemical method. wat res uk 1998, 32(4):1059-1066.
    • (1998) wat res uk , vol.32 , Issue.4 , pp. 1059-1066
    • Lin, S.1    shyu, C.2    sun, M.3
  • 5
    • 0025067746 scopus 로고
    • Reverse osmosis membrane fouling - the final frontier
    • DAVID P. Reverse osmosis membrane fouling - the final frontier. Ultra Pure Water 1990, 7(3):25-36.
    • (1990) Ultra Pure Water , vol.7 , Issue.3 , pp. 25-36
    • David, P.1
  • 6
    • 0025067746 scopus 로고
    • Reverse osmosis membrane fouling - the final frontier
    • Paul David, Abanmy Rahman M. Reverse osmosis membrane fouling - the final frontier. Ultra Pure Water 1990, 7(3):25-36.
    • (1990) Ultra Pure Water , vol.7 , Issue.3 , pp. 25-36
    • Paul, D.1    Abanmy, R.M.2
  • 7
    • 78650783039 scopus 로고    scopus 로고
    • Filmtec reverse osmosis membranes
    • January, Dow Liquid Separations
    • Dow Liquid Separations Filmtec reverse osmosis membranes. Technical Manual Trademark of the Dow Chemical Company 2004, 179. January.
    • (2004) Technical Manual Trademark of the Dow Chemical Company , pp. 179
  • 8
    • 0038388248 scopus 로고    scopus 로고
    • Pretreatment for membrane water treatment systems: a laboratory study
    • WEND C.F. Pretreatment for membrane water treatment systems: a laboratory study. Water Research 2003, 3(7):3367-3378.
    • (2003) Water Research , vol.3 , Issue.7 , pp. 3367-3378
    • Wend, C.F.1
  • 9
    • 33751394941 scopus 로고    scopus 로고
    • Membrane processes for water reuse from the effluent of industrial park wastewater treatment plant: a study on flux and fouling of membrane
    • JUANG L. Membrane processes for water reuse from the effluent of industrial park wastewater treatment plant: a study on flux and fouling of membrane. Desalination 2007, 202:302-309.
    • (2007) Desalination , vol.202 , pp. 302-309
    • Juang, L.1
  • 10
    • 78650768777 scopus 로고    scopus 로고
    • Experiences with fouling resistant membranes in combination with intermittent biocide dosage
    • SEHN P. Experiences with fouling resistant membranes in combination with intermittent biocide dosage. 9th Aachen Membrane Colloquium, Verlag Mainz, Aachen 2003.
    • (2003) 9th Aachen Membrane Colloquium, Verlag Mainz, Aachen
    • Sehn, P.1
  • 11
    • 8644278954 scopus 로고    scopus 로고
    • Early discovery of RO membrane fouling and real-time monitoring of plant performance for optimizing cost of water
    • SAAD M.A. Early discovery of RO membrane fouling and real-time monitoring of plant performance for optimizing cost of water. Desalination 2004, 165:183-191.
    • (2004) Desalination , vol.165 , pp. 183-191
    • Saad, M.A.1
  • 12
    • 78650795095 scopus 로고    scopus 로고
    • The role of membrane technologies in supplying drinking and industrial water in Tunisia: conventional process and new trends
    • Salah B. The role of membrane technologies in supplying drinking and industrial water in Tunisia: conventional process and new trends. INRST Hammam Lif Tunisia 2002, 95:20-50.
    • (2002) INRST Hammam Lif Tunisia , vol.95 , pp. 20-50
    • Salah, B.1
  • 13
    • 14844291415 scopus 로고    scopus 로고
    • The future for electro coagulation as localized water treatment technology
    • HOLT P.K. The future for electro coagulation as localized water treatment technology. Chemosphere 2005, 59:355-367.
    • (2005) Chemosphere , vol.59 , pp. 355-367
    • Holt, P.K.1
  • 14
    • 77956587068 scopus 로고    scopus 로고
    • Removal of COD and turbidity to improve wastewater quality using electro coagulation technique
    • Faiqun M. Removal of COD and turbidity to improve wastewater quality using electro coagulation technique. Malaysian Journal of Analytical Sciences 2007, 11(1):198-205.
    • (2007) Malaysian Journal of Analytical Sciences , vol.11 , Issue.1 , pp. 198-205
    • Faiqun, M.1
  • 15
    • 77956587068 scopus 로고    scopus 로고
    • Removal of COD and turbidity to improve wastewater quality using electro coagulation technique
    • Ni'am Moh Faiqun, Othman Fadil, Sohaili Johan, Fauzia Zulfa Removal of COD and turbidity to improve wastewater quality using electro coagulation technique. The Malaysian Journal Analytical Sciences 2007, 11(1):198-205.
    • (2007) The Malaysian Journal Analytical Sciences , vol.11 , Issue.1 , pp. 198-205
    • Ni'am, M.F.1    Othman, F.2    Sohaili, J.3    Fauzia, Z.4
  • 16
    • 0034117729 scopus 로고    scopus 로고
    • Separation of pollutants from restaurant wastewater by electrocoagulation
    • Chen X., Chen G., Yue P.L. Separation of pollutants from restaurant wastewater by electrocoagulation. Separation and Purification Techology 2000, 19:65-76.
    • (2000) Separation and Purification Techology , vol.19 , pp. 65-76
    • Chen, X.1    Chen, G.2    Yue, P.L.3
  • 17
    • 0038693005 scopus 로고    scopus 로고
    • Treatment of textile wastewaters by electrocoagulation using iron and aluminum electrodes
    • Kobya M., Can O.T., Bayramoglu M. Treatment of textile wastewaters by electrocoagulation using iron and aluminum electrodes. Journal of Hazardous Materials 2003, B100:163-178.
    • (2003) Journal of Hazardous Materials , vol.100 , pp. 163-178
    • Kobya, M.1    Can, O.T.2    Bayramoglu, M.3
  • 18
    • 13444306216 scopus 로고    scopus 로고
    • Deciphering the science behind electro coagulation to remove suspended clay particles from water
    • Holt P.K., Barton G.W., Mitchell C.A. Deciphering the science behind electro coagulation to remove suspended clay particles from water. Water Science and Technology 2004, 50(12):177-184.
    • (2004) Water Science and Technology , vol.50 , Issue.12 , pp. 177-184
    • Holt, P.K.1    Barton, G.W.2    Mitchell, C.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.