메뉴 건너뛰기




Volumn 2, Issue , 2010, Pages 511-513

Relationships between the three-dimension morphologic parameters of proximal femurs

Author keywords

Correlation; Density; Proximal femur; QCT; Three dimensional parameters

Indexed keywords

CORRELATION; DENSITY; PROXIMAL FEMUR; QCT; THREE-DIMENSIONAL PARAMETERS;

EID: 78650666220     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BMEI.2010.5639978     Document Type: Conference Paper
Times cited : (3)

References (10)
  • 1
    • 0024544489 scopus 로고
    • Muirhead-Allwood W, Morphology of the femur in proximal femoral fractures
    • Ferris BD, Kennedy C, Bhamra M, "Muirhead-Allwood W, Morphology of the femur in proximal femoral fractures," J Bone Joint Surg Br, vol. 71, pp. 475-477, 1989.
    • (1989) J Bone Joint Surg Br , vol.71 , pp. 475-477
    • Ferris, B.D.1    Kennedy, C.2    Bhamra, M.3
  • 3
    • 0027377070 scopus 로고
    • Simple measurement of femoral geometry predicts hip fracture: The study of osteoporotic fractures
    • Faulkner KG, Cummings SR, Black D, Palermo L, Gluer CC, Genant HK, "Simple measurement of femoral geometry predicts hip fracture: the study of osteoporotic fractures," J Bone Miner Res, vol. 8, pp. 1211-1217, 1993.
    • (1993) J Bone Miner Res , vol.8 , pp. 1211-1217
    • Faulkner, K.G.1    Cummings, S.R.2    Black, D.3    Palermo, L.4    Gluer, C.C.5    Genant, H.K.6
  • 4
    • 0028786324 scopus 로고
    • Measurement of femoral geometry in type I and type II osteoporosis: Differences in hip axis length consistent with heterogeneity in the pathogenesis of osteoporotic fractures
    • Boonen S te al, "Measurement of femoral geometry in type I and type II osteoporosis: differences in hip axis length consistent with heterogeneity in the pathogenesis of osteoporotic fractures," J Bone Miner Res, vol. 10, pp. 1908-1912, 1995
    • (1995) J Bone Miner Res , vol.10 , pp. 1908-1912
    • Boonen, S.1
  • 6
    • 78650667499 scopus 로고    scopus 로고
    • Study on the Proximal Femoral Parameters in the Healthy Chinese
    • Jianwei Zhu, Qirong Dong, Fan Liu, Weiwei Xu, "Study on the Proximal Femoral Parameters in the Healthy Chinese," Suzhou University Journal of medical science, vol. 28, pp. 582-585, 2008.
    • (2008) Suzhou University Journal of Medical Science , vol.28 , pp. 582-585
    • Zhu, J.1    Dong, Q.2    Liu, F.3    Xu, W.4
  • 7
    • 0017041228 scopus 로고
    • Improved methods for quantitative radiographic evaluation with particular reference to total hip arthroplasty
    • Clarke IC, Gruen T, Matos M, Amstutz HC, "Improved methods for quantitative radiographic evaluation with particular reference to totalhip arthroplasty," Clin Orthop Relat Res, Nov-Dec, pp. 83-91, 1976. (Pubitemid 8003196)
    • (1976) Clinical Orthopaedics and Related Research , vol.NO. 121 , pp. 83-91
    • Clarke, I.C.1    Gruen, T.2    Matos, M.3    Amstutz, H.C.4
  • 9
    • 0028222513 scopus 로고
    • Automated evaluation of the hip axis length for predicting hip fracture
    • Faulkner KG, McClung M, Cummings SR, "Automated evaluation of the hip axis length for predicting hip fracture," J Bone Miner Res, vol. 9, pp. 1065-1070, 1994.
    • (1994) J Bone Miner Res , vol.9 , pp. 1065-1070
    • Faulkner, K.G.1    McClung, M.2    Cummings, S.R.3
  • 10
    • 0031015489 scopus 로고    scopus 로고
    • Magnification error of femoral geometry using fan beam densitometers
    • DOI 10.1007/s002239900177
    • Peacock NA, Noakes KA, Majerovic Y, Griffiths MR, "Magnification error of femoral geometry using fan beam densitometers, " Calcif Tissue Int, vol. 60, pp. 8-10, 1997. (Pubitemid 27021323)
    • (1997) Calcified Tissue International , vol.60 , Issue.1 , pp. 8-10
    • Pocock, N.A.1    Noakes, K.A.2    Majerovic, Y.3    Griffiths, M.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.