Gestational age- and estimated fetal weight-adjusted reference ranges for myocardial tissue Doppler indices at 24-41 weeks' gestation

Author keywords

cardiac function; echocardiography; myocardial peak velocities; myocardial performance index; tissue Doppler imaging

Indexed keywords

ADULT; ARTICLE; CROSS-SECTIONAL STUDY; DOPPLER ECHOCARDIOGRAPHY; ECHOGRAPHY; FEMALE; FETUS ECHOGRAPHY; FETUS HEART; FETUS WEIGHT; GESTATIONAL AGE; HEART MUSCLE; HEART VENTRICLE; HEART VENTRICLE SEPTUM; HUMAN; METHODOLOGY; PHYSIOLOGY; PREGNANCY; PROSPECTIVE STUDY; REFERENCE VALUE; REGRESSION ANALYSIS; REPRODUCIBILITY;

EID: 78650644949     PISSN: 09607692     EISSN: 14690705     Source Type: Journal    
DOI: 10.1002/uog.8870     Document Type: Article
Times cited : (88)

References (36)
  • 1
    • 27644569661 scopus 로고    scopus 로고
    • Assessing fetal cardiac ventricular function
    • DeVore GR,. Assessing fetal cardiac ventricular function. Semin Fetal Neonatal Med 2005; 10: 515-541.
    • (2005) Semin Fetal Neonatal Med , vol.10 , pp. 515-541
    • Devore, G.R.1
  • 2
    • 18844464337 scopus 로고    scopus 로고
    • Tissue Doppler imaging: Current and potential clinical applications
    • Price DJ, Wallbridge DR, Stewart MJ,. Tissue Doppler imaging: current and potential clinical applications. Heart 2000; 84: 1111-1118.
    • (2000) Heart , vol.84 , pp. 1111-1118
    • Price, D.J.1    Wallbridge, D.R.2    Stewart, M.J.3
  • 6
    • 0141450673 scopus 로고    scopus 로고
    • Fetal tissue Doppler, a new technique for perinatal cardiology
    • Huhta JC, Kales E, Casbohm A,. Fetal tissue Doppler, a new technique for perinatal cardiology. Curr Opin Pediatr 2003; 15: 472-474.
    • (2003) Curr Opin Pediatr , vol.15 , pp. 472-474
    • Huhta, J.C.1    Kales, E.2    Casbohm, A.3
  • 7
    • 25844490081 scopus 로고    scopus 로고
    • Reference charts of gestation-specific tissue Doppler imaging indices of systolic and diastolic functions in the normal fetal heart
    • Chan LY, Fok WY, Wong JT, Yu CM, Leung TN, Lau TK,. Reference charts of gestation-specific tissue Doppler imaging indices of systolic and diastolic functions in the normal fetal heart. Am Heart J 2005; 150: 750-755.
    • (2005) Am Heart J , vol.150 , pp. 750-755
    • Chan, L.Y.1    Fok, W.Y.2    Wong, J.T.3    Yu, C.M.4    Leung, T.N.5    Lau, T.K.6
  • 8
    • 77954060576 scopus 로고    scopus 로고
    • Tissue Doppler is more sensitive than standard echocardiography to detect cardiac dysfunction in early stages of IUGR
    • Comas M, Crispi F, Cruz-Martinez R, Martinez JM, Figueras F, Gratacõs E,. Tissue Doppler is more sensitive than standard echocardiography to detect cardiac dysfunction in early stages of IUGR. Am J Obstet Gynecol 2010; 203: 45.e1-45.e7.
    • (2010) Am J Obstet Gynecol , vol.203
    • Comas, M.1    Crispi, F.2    Cruz-Martinez, R.3    Martinez, J.M.4    Figueras, F.5    Gratacõs, E.6
  • 12
    • 0346690219 scopus 로고    scopus 로고
    • Quantitative Assessment of Right Ventricular Function Using Doppler Tissue Imaging in Fetuses with and without Heart Failure
    • DOI 10.1016/j.echo.2003.09.012
    • Aoki M, Harada K, Ogawa M, Tanaka T,. Quantitative assessment of right ventricular function using doppler tissue imaging in fetuses with and without heart failure. J Am Soc Echocardiogr 2004; 17: 28-35. (Pubitemid 38064112)
    • (2004) Journal of the American Society of Echocardiography , vol.17 , Issue.1 , pp. 28-35
    • Aoki, M.1    Harada, K.2    Ogawa, M.3    Tanaka, T.4
  • 17
    • 0018424772 scopus 로고
    • The accuracy of radiological estimates of gestational age using early fetal crown-rump length measurements by ultrasound as a basis for comparison
    • Robinson HP, Sweet EM, Adam AH,. The accuracy of radiological estimates of gestational age using early fetal crown-rump length measurements by ultrasound as a basis for comparison. Br J Obstet Gynaecol 1979; 86: 525-528.
    • (1979) Br J Obstet Gynaecol , vol.86 , pp. 525-528
    • Robinson, H.P.1    Sweet, E.M.2    Adam, A.H.3
  • 18
    • 0021339720 scopus 로고
    • Sonographic estimation of fetal weight: The value of femur length in addition to head and abdomen measurements
    • Hadlock FP, Harrist RB, Carpenter RJ, Deter RL, Park SK,. Sonographic estimation of fetal weight: the value of femur length in addition to head and abdomen measurements. Radiology 1984; 150: 535-540.
    • (1984) Radiology , vol.150 , pp. 535-540
    • Hadlock, F.P.1    Harrist, R.B.2    Carpenter, R.J.3    Deter, R.L.4    Park, S.K.5
  • 19
    • 49849104609 scopus 로고    scopus 로고
    • Comparison between pulsed-wave Doppler and tissue Doppler-derived Tei indices in fetuses with and without congenital heart disease
    • Acharya G, Pavlovic M, Ewing L, Nollmann D, Leshko J, Huhta JC,. Comparison between pulsed-wave Doppler and tissue Doppler-derived Tei indices in fetuses with and without congenital heart disease. Ultrasound Obstet Gynecol 2008; 31: 406-411.
    • (2008) Ultrasound Obstet Gynecol , vol.31 , pp. 406-411
    • Acharya, G.1    Pavlovic, M.2    Ewing, L.3    Nollmann, D.4    Leshko, J.5    Huhta, J.C.6
  • 20
    • 0031906310 scopus 로고    scopus 로고
    • How to construct 'normal ranges' for fetal variables
    • Royston P, Wright EM,. How to construct 'normal ranges' for fetal variables. Ultrasound Obstet Gynecol 1998; 11: 30-38.
    • (1998) Ultrasound Obstet Gynecol , vol.11 , pp. 30-38
    • Royston, P.1    Wright, E.M.2
  • 22
    • 33751326385 scopus 로고    scopus 로고
    • Assessment of the evolution of normal fetal diastolic function during mid and late gestation by spectral Doppler tissue echocardiography
    • Nii M, Roman KS, Kingdom J, Redington AN, Jaeggi ET,. Assessment of the evolution of normal fetal diastolic function during mid and late gestation by spectral Doppler tissue echocardiography. J Am Soc Echocardiogr 2006; 19: 1431-1437.
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 1431-1437
    • Nii, M.1    Roman, K.S.2    Kingdom, J.3    Redington, A.N.4    Jaeggi, E.T.5
  • 23
    • 77949699389 scopus 로고    scopus 로고
    • Comparison of tissue Doppler velocities obtained by different types of echocardiography systems: Are they compatible?
    • Dénes M, Farkas K, Erdei T, Lengyel M,. Comparison of tissue Doppler velocities obtained by different types of echocardiography systems: are they compatible? Echocardiography 2010; 27: 230-235.
    • (2010) Echocardiography , vol.27 , pp. 230-235
    • Dénes, M.1    Farkas, K.2    Erdei, T.3    Lengyel, M.4
  • 24
    • 59049101732 scopus 로고    scopus 로고
    • Comparison of myocardial performance index obtained either by conventional echocardiography or tissue Doppler echocardiography in healthy subjects and patients with heart failure
    • Duzenli MA, Ozdemir K, Aygul N, Soylu A, Aygul MU, Gök H,. Comparison of myocardial performance index obtained either by conventional echocardiography or tissue Doppler echocardiography in healthy subjects and patients with heart failure. Heart Vessels 2009; 24: 8-15.
    • (2009) Heart Vessels , vol.24 , pp. 8-15
    • Duzenli, M.A.1    Ozdemir, K.2    Aygul, N.3    Soylu, A.4    Aygul, M.U.5    Gök, H.6
  • 25
    • 29244435772 scopus 로고    scopus 로고
    • Left ventricle myocardial performance index derived either by conventional method or mitral annulus tissue-Doppler: A comparison study in healthy subjects and subjects with heart failure
    • Gaibazzi N, Petrucci N, Ziacchi V,. Left ventricle myocardial performance index derived either by conventional method or mitral annulus tissue-Doppler: a comparison study in healthy subjects and subjects with heart failure. J Am Soc Echocardiogr 2005; 18: 1270-1276.
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1270-1276
    • Gaibazzi, N.1    Petrucci, N.2    Ziacchi, V.3
  • 26
    • 33751307960 scopus 로고    scopus 로고
    • Left ventricular Tei index in children: Comparison of tissue Doppler imaging, pulsed wave Doppler, and M-mode echocardiography normal values
    • Cui W, Roberson DA,. Left ventricular Tei index in children: comparison of tissue Doppler imaging, pulsed wave Doppler, and M-mode echocardiography normal values. J Am Soc Echocardiogr 2006; 19: 1438-1445.
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 1438-1445
    • Cui, W.1    Roberson, D.A.2
  • 28
    • 3042841184 scopus 로고    scopus 로고
    • Left and right ventricular adaptation assessed by Doppler tissue echocardiography in athletes
    • Pelà G, Bruschi G, Montagna L, Manara M, Manca C,. Left and right ventricular adaptation assessed by Doppler tissue echocardiography in athletes. J Am Soc Echocardiogr 2004; 17: 205-211.
    • (2004) J Am Soc Echocardiogr , vol.17 , pp. 205-211
    • Pelã, G.1    Bruschi, G.2    Montagna, L.3    Manara, M.4    Manca, C.5
  • 29
    • 45849115387 scopus 로고    scopus 로고
    • Longitudinal plane colour tissue-Doppler myocardial velocities and their association with left ventricular length, volume, and mass in humans
    • Batterham A, Shave R, Oxborough D, Whyte G, George K,. Longitudinal plane colour tissue-Doppler myocardial velocities and their association with left ventricular length, volume, and mass in humans. Eur J Echocardiogr 2008; 9: 542-546.
    • (2008) Eur J Echocardiogr , vol.9 , pp. 542-546
    • Batterham, A.1    Shave, R.2    Oxborough, D.3    Whyte, G.4    George, K.5
  • 30
    • 37249066257 scopus 로고    scopus 로고
    • Left ventricular function in professional football players evaluated by tissue Doppler imaging and strain imaging
    • Tümüklü MM, Etikan I, Cinar CS,. Left ventricular function in professional football players evaluated by tissue Doppler imaging and strain imaging. Int J Cardiovasc Imaging 2008; 24: 25-35.
    • (2008) Int J Cardiovasc Imaging , vol.24 , pp. 25-35
    • Tümüklü, M.M.1    Etikan, I.2    Cinar, C.S.3
  • 31
    • 0036736655 scopus 로고    scopus 로고
    • Assessment of regional systolic and diastolic wall motion velocities in highly trained athletes by pulsed wave Doppler tissue imaging
    • Zoncu S, Pelliccia A, Mercuro G,. Assessment of regional systolic and diastolic wall motion velocities in highly trained athletes by pulsed wave Doppler tissue imaging. J Am Soc Echocardiogr 2002; 15: 900-905.
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 900-905
    • Zoncu, S.1    Pelliccia, A.2    Mercuro, G.3
  • 32
    • 33747595975 scopus 로고    scopus 로고
    • Fetal cardiac output, distribution to the placenta and impact of placental compromise
    • Kiserud T, Ebbing C, Kessler J, Rasmussen S,. Fetal cardiac output, distribution to the placenta and impact of placental compromise. Ultrasound Obstet Gynecol 2006; 28: 126-136.
    • (2006) Ultrasound Obstet Gynecol , vol.28 , pp. 126-136
    • Kiserud, T.1    Ebbing, C.2    Kessler, J.3    Rasmussen, S.4
  • 33
    • 33947376434 scopus 로고    scopus 로고
    • Cardiovascular hemodynamics and umbilical artery N-terminal peptide of proB-type natriuretic peptide in human fetuses with growth restriction
    • Girsen A, Ala-Kopsala M, Mäkikallio K, Vuolteenaho O, Räsänen J,. Cardiovascular hemodynamics and umbilical artery N-terminal peptide of proB-type natriuretic peptide in human fetuses with growth restriction. Ultrasound Obstet Gynecol 2007; 29: 296-303.
    • (2007) Ultrasound Obstet Gynecol , vol.29 , pp. 296-303
    • Girsen, A.1    Ala-Kopsala, M.2    Mäkikallio, K.3    Vuolteenaho, O.4    Räsänen, J.5
  • 35